Unsupported content This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.

Service Pack 3: version 8.3.03


This topic contains information about fixes and updates in BMC Server Automation 8.3 Service Pack 3 (product version 8.3.03), and provides instructions for downloading and installing the service pack.

Tip

For information about issues corrected in this service pack, see Known-and-corrected-issues.

Enhancements

The following topics describe the updates and enhancements included in this service pack.

Tip

Click here to create a PDF containing only content related to Service Pack 3.

Downloading the service pack

Service Pack 3 for BMC Server Automation 8.3.00 includes full installers for all components. You can download the files for version 8.3.03 from the BMC Electronic Product Distribution (EPD) website. For download instructions, see Downloading-the-installation-files. For a list of installation programs by OS, see Installation-programs-for-BMC-Server-Automation

Installing the service pack as a fresh product installation

If you are installing this service pack as a fresh product installation, download the Service Pack files and then follow the instructions in Performing-the-installation.

After configuring the database, run the scripts found in the 83SP3-SQL_Update_Scripts.zip file. This file is available in the BMC Server Automation 8.3.03 section of the EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin). For more detailed instructions, see Running-the-SQL-update-scripts.

Upgrading to the service pack

To upgrade to the service pack, follow the instructions in Upgrading.

Note

The installation programs for BMC Vendor Patch Management were not upgraded for service packs. If you have installed version 8.3.00 for this program, you do not need to upgrade these programs when upgrading to the service pack level.

Supported upgrade paths

The following table lists information for the most recent BMC Server Automation version 8.3 builds.

Release

Build number

EPD version number

Release date

Service Pack 3

8.3.03.082

8.3.03

February 21, 2014

Service Pack 2 Patch 1

8.3.02.407

8.3.02.001

December 18, 2013

Service Pack 2

8.3.02.332

8.3.02

August 30, 2013

Service Pack 1

8.3.01.160

8.3.01

May 15, 2013

Base version 8.3

8.3.00.114

8.3.00

January 14, 2013

The following list identifies the supported upgrade paths:

  • Version 8.3.00 to any later 8.3 service pack or patch
  • Version 8.2 direct to version 8.3.x
  • Version 8.1 direct to version 8.3.x
  • 8.0 to SP6 to version 8.3.x

    To upgrade from an 8.0 version earlier than 8.0 SP6, first apply SP6.

Special upgrade scenarios

Note the following special tasks that you must perform during an upgrade to a service pack, after upgrading the Application Server and Console:

Special condition or scenario

Task description

If upgrading from 8.2.x or earlier

Run the Data Migration Manager using the version 8.3 external files to upgrade your Oracle or SQL Server database to version 8.3.

Any upgrade

Run the SQL Update scripts found in the 83SP3-SQL_Update_Scripts.zip file. This file is available in the BMC Server Automation 8.3.03 section of the EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin).

If upgrading from a version earlier than 8.0

Run the postmigration file to migrate pre-8.x compliance rules and discovery signatures.

If smart group conditions were defined in any earlier version

Run the postmigration file to migrate and update smart group conditions.

Considerations in service pack implementation for patch management on Windows

If you are using Microsoft Windows, review the following considerations for patch management.

Resolving a potential RSCD Agent installation problem

If the target system is in a pending reboot state (for example, from a previous patch or other software installation), you can use the PENDINGREBOOTFORCE flag to allow the MSI installer to ignore the pending reboot state and allow the installation to proceed. After you confirm that the pending reboot state on the target is not a result of a previous RSCD installation, you can set PENDINGREBOOTFORCE=1. A command-line sample for the MSI installation program follows:

msiexec /I RSCD83-SP1.WIN32.msi /qn REBOOT=ReallySuppress PENDINGREBOOTFORCE=1

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*