UCSTemplate - addLanNicToTemplateBootOrder


UCSTemplate - addLanNicToTemplateBootOrder

Description :

This command adds a LAN NIC to a UCS template's boot order. You can add a maximum of 2 LAN NICs to the boot order.

Set the order argument to 0 to indicate the first NIC in the internal boot order. Set the order argument to 1 to indicate the second NIC in the internal boot order. You must set the first NIC (0) before you set the second NIC (1).

Use the templateKey argument to specify the DBKey of the template you want to modify. You can get the DBKey of the template by using the DepotObject : getDBKeyByTypeStringGroupAndName command.

Return type : Boolean

Command Input :

Variable Name

Variable Type

Description

templateKey

com.bladelogic.om.infra.model.base.keys.SDepotObjectKey

The DBKey of the template you want to modify.

index

Integer

The index of the element in the LAN NIC list configured for the the template.The index starts from 0.

mainIndex

Integer

The index of the LAN NIC in the main boot order.Set the index to -1 to add the LAN NIC at the end of the list.

order

Integer

The index of the LAN NIC in the internal boot order.

Example

The following example adds a LAN NIC to the boot order of a UCS template.

Script





blcli UCSTemplate addLanNicToTemplateBootOrder DBKey:SDepotObjectKey:2000003-1 0 -1 0



 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC Server Automation Command Line Interface 8.7