Performing the BMC BladeLogic Atrium Integration installation


The following topics provide information about installing BMC BladeLogic Atrium Integration.

Error
Warning

The BMC BladeLogic Atrium Integration installer supports the English, French, Simplified Chinese, and Japanese locales only.

Before you begin

  • Make sure that compatible versions of BMC Server Automation, BMC Atrium CMDB, and BMC Atrium Integration Engine are installed, licensed, and running.
    At the time of this release, the product versions listed in the following table have been tested as compatible:

    Warning

    Note

    • BMC BladeLogic Atrium Integration works with all the supported databases of BMC BladeLogic Decision Support for Server Automation. For information about this product, see BMC BladeLogic Decision Support for Server Automation documentation.
    • For the latest information, see the product compatibility matrix for BMC Server Automation on the Support website.
  • Run the BMC BladeLogic Decision Support for Server Automation Extract, Transform, and Load (ETL) tool before installing BMC BladeLogic Atrium Integration.
  • If you are re-installing BMC BladeLogic Atrium Integration, the installer takes more time because of deletion and recreation of component templates (created by the BMC BladeLogic Atrium Integration installer) and discovered components. The following table summarizes the approximate time required for deleting discovered components, under ideal conditions. This information will help you estimate the re-installation time better.

    Number of discovered components

    Average deletion time (in seconds)

    500

    90

    1000

    175.5

    1500

    259

    2000

    345.5

    4000

    682.5

  • You need a user name and password for the EPD site. You can register and obtain credentials at http://www.bmc.com/support.
  • Obtain a support ID and password for BMC BladeLogic Atrium Integration from your BMC Software sales representative.
  • You need all the information listed in Installation-worksheet-for-BMC-BladeLogic-Atrium-Integration.

 

 

  • (Linux platforms) Install the X Windows system (X11) and the xorg-x11-libs library on the computer running the BMC BladeLogic Atrium Integration installer.
  • (Linux platforms) Define a DISPLAY variable. For example, hostname0.0
  • (Linux platforms) You can use the silent mode of installation in a headless environment ( a computer without a display device, keyboard, or a mouse). However, if the DISPLAY variable in the environment is set to to export the display to a remote system, ensure that the remote system has an X Windows server installed and configured.
  • (Linux platforms) The /tmp directory must have atleast 500 MB of free space. If your computer does not have 500 MB of free space in the /tmp directory, you can also set the IATEMPDIR environment variable to the absolute path of a directory that has at least 500 MB of free space.

Where to go from here

  1. Complete the configuration tasks listed in Configuring-BMC-BladeLogic-Atrium-Integration-after-installation.
  2. Activate the data exchanges in the BMC Atrium Engine data exchange Console.
     For more information about the data exchanges that are created automatically in BMC Atrium Integration Engine after installing BMC BladeLogic Atrium Integration, see Understanding-integration-data-exchanges. For more information about activating data exchanges, see BMC Atrium CMDB documentation.
  3. Create Indexes as explained in Performance-settings.
  4. You can set schedules on BL_LOAD_SRVR_PROPS as required. All other exchanges are triggered by this exchange.
  5. Customize BMC Server Automation data mappings. See Customizing-data-mappings-between-BMC-Server-Automation-and-BMC-Atrium-CMDB for more details.
  6. Run the ETL tool.
     For information about the ETL components of BMC BladeLogic Decision Support for Server Automation, see BMC BladeLogic Decision Support for Server Automation documentation.
  7. Restart the BMC Atrium Integration Engine service.

During installation, BMC BladeLogic Atrium Integration creates data exchanges and data mappings in BMC Atrium Integration Engine for the CI classes and relationship classes that are discoverable by BMC Server Automation.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC BladeLogic Automation Suite 8.2