TrueSight Orchestration Operator Control Panel fails to start
administrators can use these steps if the
Operator Control Panel fails to start and displays the following error:
The server returned an error:java.lang.RuntimeException: Cant handle request because grid identifier couldnt be determined for grid name = "gridName".
- In Grid Manager, verify the name of the grid:
- If the grid name is different (other than the case) from the one that appears in the error message, contact your system administrator for further troubleshooting. Do not proceed further.
- If the name is the same as the grid name that appears in the error message except for the case, proceed as follows:
- On the CDP computer, stop the authentication service and CDP service.
- Using a text editor, open the \\AO_Home\tomcat\conf\context.xml file.
Search for grid and change the value to match exactly the name of the grid.
- Save the context.xml file.
- Restart the authentication service and CDP service.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*