Perform Boot Config EMS EDIT


Enables changes to port settings.

Warning

Note

This workflow is available for use only in Microsoft Windows environments.

 Workflow inputs – Perform Boot Config EMS EDIT

Call Workflow Input

Description

Required

Default Value

connection details

XML document conforming to the Connection Details common object that contains the information required to execute a command via command line.

Yes

n/a

port

Specifies the COM port to be used for redirection.

No

There is no default value.

baud

Specifies the baud rate to be used for redirection.

 

Warning

Note

Do not use the /baud parameter if remotely administered output is being disabled.

No

There is no default value.

os entry line num

Specifies the operating system entry line number in the operating systems section of the Boot.ini file to copy. The first line after the operating systems section header is 1.

No

There is no default value.

 

 Workflow outputs – Perform Boot Config EMS EDIT

Call Workflow Output

Description

output

XML document consisting of one or more <line> elements that contain the command response. Each <line> element contains an index attribute indicating the order in which the information was returned by the command.

success

Did the operation succeed?

 

Valid values: true, false

 