get-event-by-id operation


The get-event-by-id operation retrieves an event that is identified by the specified globally unique identifier (GUID).

The following table describes the <items> XML and request elements for the get-event-by-id operation:

Adapter request elements for the get-event-by-id operation

The following figure illustrates a sample adapter request for the get-event-by-id operation:

Sample adapter request for the get-event-by-id operation

<scom-request>
 <operation-name>get-event-by-id</operation-name>
 <command-request>
   <timeout-secs>120</timeout-secs>
   <command-parameters>
     <event-id>425d013b-bf1d-4109-9c3a-f52bb863acbd</event-id>
   </command-parameters>
 </command-request>
</scom-request>


The following figure illustrates the adapter response for the sample request:

Sample adapter response for the get-event-by-id operation

<scom-response>
 <metadata>
   <status>success</status>
   <count>1</count>
 </metadata>
 <commands-output>
   <command-output>
     <metadata>
       <command>./Microsoft.EnterpriseManagement.OperationsManager.ClientShell.
       Startup.ps1;get-event -id 06b171ac-d83f-42fb-b484-03aecd66c599</command>
       <execution-milliseconds>4578</execution-milliseconds>
       <exit-code>0</exit-code>
       <status>success</status>
       <count>1</count>
     </metadata>
     <output>
       <item>
         <Id>06b171ac-d83f-42fb-b484-03aecd66c599</Id>
         <OriginalId>9922f350-f488-42f4-a4a6-fbc6b2ffd251</OriginalId>
         <MonitoringObjectId>adb901fe-08f4-490e-722f-d65430015064</MonitoringObjectId>
         <MonitoringClassId>ab4c891f-3359-3fb6-0704-075fbfe36710</MonitoringClassId>
         <MonitoringObjectName />
         <MonitoringObjectDisplayName>win2stdvm.neuron.com</MonitoringObjectDisplayName>
         <MonitoringObjectPath>win2stdvm.neuron.com</MonitoringObjectPath>
         <MonitoringObjectFullName>win2stdvm.neuron.com</MonitoringObjectFullName>
         <MonitoringRuleId>fe17ed88-9f59-8b80-b1a5-ee42b80b95c8</MonitoringRuleId>
         <MonitoringRuleDisplayName>Collect Distributed Workflow Test Event</MonitoringRuleDisplayName>
         <MonitoringRuleDescription>Collects events logged by the "Log
          Distributed Workflow Test Event" rule</MonitoringRuleDescription>
         <PublisherName>Health Service Script</PublisherName>
         <Number>6022</Number>
         <Description>LogEndToEndEvent.js : This event is logged to the Windows
          Event Log periodically to test a event collection.</Description>
         <CategoryId>0</CategoryId>
         <Category />
         <User>N/A</User>
         <Channel>Operations Manager</Channel>
         <LevelId>4</LevelId>
         <Level />
         <LoggingComputer>WIN2STDVM</LoggingComputer>
         <EventData />
         <Parameters>{LogEndToEndEvent.js, This event is logged to the Windows
          Event Log periodically to test a event collection.}</Parameters>
         <TimeGenerated>04/03/2009 10:00:00 AM</TimeGenerated>
         <TimeAdded>04/03/2009 10:00:14 AM</TimeAdded>
         <ManagementGroup>M1</ManagementGroup>
         <ManagementGroupId>ae1fcf8a-8088-31d8-93ec-90fe77a32d44</ManagementGroupId>
       </item>
     </output>
   </command-output>
 </commands-output>
</scom-response>

 