Configuring the HP Operations Manager monitor adapter


You can specify the adapter configuration elements for the monitor adapter for HP Operations Manager by using the form view, the XML view, or both. You cannot use the form view to configure elements and attributes that do not have an entry in the UI label column.

To configure the monitor adapter

  1. Log on to TrueSight Orchestration Grid Manager.
  2. To access the adapters page, click the Manage tab, and then click the Adapters tab.
  3. In the Adapters in Repository list, select the bmc-adapter-hp-operations-manager-monitor check box.
  4. To include the adapter in the Adapters on Grid list, click Add to Grid.
  5. Click Configure corresponding to the newly added adapter.
  6. On the Add an Adapter Configuration page, perform the following steps to configure the adapter by using the form view, or skip to step 7 to configure the adapter by using the XML view:
    1. Enter a name for the adapter.
    2. Enter a description for the adapter.
    3. Under Properties, enter or select values for the configuration elements.

      Include all required elements, which are indicated with an asterisk (*).
    4. Click OK.

      The newly configured adapter is now listed in the Adapters on Grid list.
  7.  (O ptional ) Configure the adapter in the XML view by performing the following steps:

    Note

    Switching to the XML view means that you cannot thereafter use the form view for modifying that configuration.

    1. Enter a name and a description for the adapter.
    2. Click Switch to XML View.
    3. On the Warning message that appears, click Switch View.
    4. In the Properties text box, use XML format to enter the configuration elements and attributes, and then click OK.

      Note

      If the default value for an optional element is acceptable, omit the element. Do not include empty elements.

    5. On the Warning message that appears, click Save.

      The adapter configuration with settings is saved in the XML view permanently. The newly configured adapter is now listed in the Adapters on Grid list.

The following table describes the configuration elements for the monitor adapter. You cannot use the form view to configure elements and attributes that do not have an entry in the UI label column.

Node elements required for configuring the monitor adapter

 


The following figure shows an XML template for configuring the monitor adapter:

XML template for configuring the monitor adapter

<config>
 <username></username>
 <password></password>
 <host></host>
 <port></port>
 <wsdl-url></wsdl-url>
 <protocol></protocol>
 <polling-interval></polling-interval>
 <arguments>
    <severity></severity>
 </arguments>
 <use-ssl-certificate></use-ssl-certificate>
 <allow-unsigned-certificate></allow-unsigned-certificate>
 <install-certificate></install-certificate>
 <passphrase></passphrase>
</config>

Enabling custom logging

To enable custom logging for the adapter, you must specify a log file name. You can also provide additional parameters for logging.

Note

You must be using TrueSight Orchestration version 8.1 or later to use the custom logging feature. These parameters will be ignored in earlier versions of TrueSight Orchestration Platform.

These parameters are available with supported adapter versions. See TrueSight Orchestration Content documentation for details.

  • Log File Name: Provide a name for the log file.
    This file will be stored in the AO_HOME/tomcat/logs directory. If Log File Max Backup Index value is greater than 0, the log file name is suffixed with the backup index. For example, if the parameter value is a.log, backup log files will have names, such as a.log.1, a.log.2.
  • Log File Size: Specify a size limit for the log file. 
    If the value specified for Log File Max Backup Index is greater than 0, when the specified size is reached, the current file is renamed with the suffix .1. Otherwise, the log file will be reset and over-written. The default value is 10MB. The available units are KiloBytes (KB), MegaBytes (MB) or GigaBytes (GB).
  • Log File Max Backup Index: Enter the maximum number of backup files allowed. The default value is 10.
  • Log File Append: Select this option to append new log information to the existing information in the file. If unselected, the file will be overwritten with new log information.
  • Log Level: Enter the logging level using one of the following choices:

    Logging level

    Description

    DEBUG

    The most detailed logging level; logs low-level messages, normal execution, recoverable erroneous conditions, and unrecoverable erroneous conditions

    INFO

    (default)

    Logs normal execution, recoverable erroneous conditions, and unrecoverable erroneous conditions

    WARN

    Logs recoverable erroneous conditions and unrecoverable erroneous conditions

    ERROR

    The least detailed logging level; logs only error conditions that are not usually recoverable

Encrypting an element's contents

You can add the attribute secure="true" to an XML adapter element XML view to ensure that the element's contents is encrypted when displayed.

Note

You must be using TrueSight Orchestration Platform version 8.1 or later to use this encryption attribute.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*