Find VMRack Details operation


The Find VMRack Details operation retrieves the details of a specified VMRack.

The following table describes the <items> XML and request elements for the Find VMRack Details operation.

Adapter request elements for the Find VMRack Details operation

The following figure illustrates a sample adapter request for the Find VMRack Details operation:

Sample adapter request for the Find VMRack Details operation

<dell-aim-request>
   <operation-name>find-vmrack-details</operation-name>
   <arguments>
     <target>config1</target>
     <vmrack-id>CH.0.11</vmrack-id>
   </arguments>
</dell-aim-request>

The following figure illustrates the adapter response for the sample request:

Sample adapter response for the Find VMRack Details operation

<dell-aim-response>
 <metadata>
   <status>success</status>
   <response-count>1</response-count>
 </metadata>
 <responses>
   <response>
     <metadata>
       <target>config1</target>
       <status>success</status>
       <count>1</count>
     </metadata>
     <output>
       <vm-racks>
         <vm-rack>
           <agent-exists>false</agent-exists>
           <app-state>runnable</app-state>
           <confirmations-enabled>false</confirmations-enabled>
           <consecutive-failures>0</consecutive-failures>
           <copy-enabled>false</copy-enabled>
           <description></description>
           <extensions-enabled>false</extensions-enabled>
           <health-monitor-enabled>false</health-monitor-enabled>
           <id>CH.0.11</id>
           <maintenance-description></maintenance-description>
           <maintenance-mode>false</maintenance-mode>
           <management-type>unknown</management-type>
           <manufacturer>ESX</manufacturer>
           <mode>normal</mode>
           <model>ESX</model>
           <name>VMware ESX 4 VMrack</name>
           <net-boot>false</net-boot>
           <network-automation-mode>readOnly</network-automation-mode>
           <network-mode>trunk</network-mode>
           <networking-enabled>true</networking-enabled>
           <os-arch>x86_32</os-arch>
           <os-family>esx</os-family>
           <routing-and-dns>managed</routing-and-dns>
           <scn-assignment-type>pool</scn-assignment-type>
           <selected-image-id>IN.3.1</selected-image-id>
           <serial-number>CH.0.11</serial-number>
           <slot-count>10</slot-count>
           <state>running</state>
           <supports-maintenance-mode>false</supports-maintenance-mode>
           <template>false</template>
           <type>esx</type>
           <vnode-management>direct</vnode-management>
           <rack-management>
             <net-address>192.9.200.206</net-address>
             <snmp-v3-auth-protocol>unknown</snmp-v3-auth-protocol>
             <snmp-v3-priv-protocol>unknown</snmp-v3-priv-protocol>
             <sys-contact>Beavis</sys-contact>
             <sys-location>Nowhere</sys-location>
             <sys-name>ESX Chassis 192.9.200.206</sys-name>
             <use-ssh>false</use-ssh>
             <use-snmp-v3>false</use-snmp-v3>
             <verify-identity>false</verify-identity>
           </rack-management>
           <version />
           <switches>
             <switch>
               <management>
                 <net-address>192.9.200.207</net-address>
                 <snmp-v3-auth-protocol>unknown</snmp-v3-auth-protocol>
                 <snmp-v3-priv-protocol>unknown</snmp-v3-priv-protocol>
                 <sys-contact>Nobody</sys-contact>
                 <sys-location>Scalent Lab, Rack 1</sys-location>
                 <sys-name>Cisco WS-C3750G-24T-.*</sys-name>
                 <use-ssh>false</use-ssh>
                 <use-snmp-v3>false</use-snmp-v3>
                 <verify-identity>false</verify-identity>
               </management>
               <channel-id>1</channel-id>
               <id>SW.0.1</id>
               <management-mode>fullyManaged</management-mode>
               <manufacturer>Cisco</manufacturer>
               <model>WS-C3750G-24T-.*</model>
               <module-count>1</module-count>
               <name>Cisco WS-C3750G-24T-.*</name>
               <state>unknown</state>
               <type>Ethernet</type>
               <validation-frequency>60</validation-frequency>
               <eth-ports>
                 <port>
                   <auto-negotiate>true</auto-negotiate>
                   <channel-id>0</channel-id>
                   <duplex>full</duplex>
                   <enabled>true</enabled>
                   <flow-control>true</flow-control>
                   <lag-type>discrete</lag-type>
                   <max-speed>1000</max-speed>
                   <name>GigabitEthernet1/0/2</name>
                   <name-abbrev>Gi1/0/2</name-abbrev>
                   <port-module>1</port-module>
                   <port-num>2</port-num>
                   <role>host</role>
                   <speed>1000</speed>
                   <state>unknown</state>
                 </port>
                  ...
               </eth-ports>
             </switch>
              ...
           </switches>
           <images>
             <image>
               <assigned-host-id>BS_1_CH.0.1</assigned-host-id>
               <assigned-rack-id>CH.0.1</assigned-rack-id>
               <boot-type>disk</boot-type>
               <id>IN.3.1</id>
               <orig-app-id>PR.3.0</orig-app-id>
             </image>
           </images>
         </vm-rack>
       </vm-racks>
     </output>
   </response>
 </responses>
</dell-aim-response>

 