Netcool OMNIbus monitor adapter events


The elements in the Tivoli Netcool/OMNIbus monitor event differ depending on whether the value for the <single-monitor-event> element defined in the adapter configuration is true or false.

The following figure describes the elements for the Tivoli Netcool/OMNIbus monitor adapter event when the value of the <single-monitor-event> element is true.

 Elements for the monitor adapter event when < single-monitor-event > is true

The following figure shows an XML sample of a Tivoli Netcool/OMNIbus monitor adapter event when the value of the <single-monitor-event> element is true.

*XML sample of a Tivoli Netcool/OMNIbus monitor adapter event value of the <single-monitor-event> element is true


<omnibus-monitor-response>
<row>
<column name="movie_id">1</column>
<column name="movie_name">Bruce Almighty</column>
<column name="movie_type">5</column>
<column name="movie_year">2003</column>
<column name="movie_leadactor">1</column>
<column name="movie_director">2</column>
<column name="movie_running_time">102</column>
<column name="movie_cost">10</column>
</row>
<row>
<column name="movie_id">2</column>
<column name="movie_name">Office Space</column>
<column name="movie_type">5</column>
<column name="movie_year">1999</column>
<column name="movie_leadactor">5</column>
<column name="movie_director">6</column>
<column name="movie_running_time">90</column>
<column name="movie_cost">3</column>
</row>
<metadata>
<query-executed>select * from movie;</query-executed>
<target-name>target1</target-name>
<response-row-count>2</response-row-ccount>
<response-column-count>8</response-column-count>
<status>success</status>
</metadata>
</omnibus-monitor-response>

The following table describes the elements for the Tivoli Netcool/OMNIbus monitor adapter event when the value of the <single-monitor-event> element is false.

 Elements of Tivoli Netcool/OMNIbus monitor adapter event when < single-monitor-event > is false

The following figure shows an <items> XML sample of a Tivoli Netcool/OMNIbus monitor adapter event when the value of the <single-monitor-event> element is false.

XML sample of a Tivoli Netcool/OMNIbus monitor adapter event when < single-monitor-event > is false


<omnibus-monitor-response>
<column name="movie_id">1</column>
<column name="movie_name">Bruce Almighty</column>
<column name="movie_type">5</column>
<column name="movie_year">2003</column>
<column name="movie_leadactor">1</column>
<column name="movie_director">2</column>
<column name="movie_running_time">102</column>
<column name="movie_cost">10</column>
</row>
<metadata>
<target-name>target1</target-name>
<query-executed>select * from movie;</query-executed>
<row-number>1</row-number>
<response-row-count>2</response-row-ccount>
<response-column-count>8</response-column-count>
<status>success</status>
</metadata>
</omnibus-monitor-response>

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*