Component status
The Components tab displays the grid components for an individual grid and indicates the status of those components for each peer on that grid.
To access the Components tab, click the grid name on the Status tab and then click the Components tab in the center of the page.
The name of the selected grid is displayed in the upper left corner of the page. The condition of the components for peers on the selected grid is displayed in a matrix, with the components listed down the left side and the configured peers for this grid across the top.
Peer components can have a status of Running, Stopped, Fault State, Master, or Not Applicable. The Not Applicable status applies to lightweight activity peers (LAPs); these streamlined peers do not contain all BMC Atrium Orchestrator components. LAPs contain only the Adapter Manager, Configuration, Health, and Library Manager components.
The Master components for the Context, Health, Job Manager, Library Manager, and Scheduler are indicated with an asterisk (*) to the left of the column for the peer that is currently serving that role.
If you drill down to the component level immediately after you create first grid, the Master icons might not be present. It takes a few moments for the Masters to be elected. After they are elected, their icons are displayed.
You can manually refresh the Components tab by clicking the Refresh icon. Alternatively, select the auto-refresh check box to automatically refresh the status view every 10 seconds.
Click the Back to Main Status link, located in the upper right corner of the page, to return to the Status tab.