Unsupported content This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.

Troubleshooting the Operations Manager 2007 adapter


This topic provides information for troubleshooting issues specific to BMC Atrium Orchestrator Application Adapter for Microsoft System Center Operations Manager 2007.


Message: AdapterManager: Unable to initialize adapter SCOMActor: Invalid OS type.

Explanation: This error message appears in the grid logs when the adapter is enabled on a peer that is installed on a computer that is not running Microsoft Windows.

User Response: Ensure that the adapter is enabled on a peer that is installed on a Windows computer.


Message: Cannot load Windows PowerShell snap-in Microsoft Enterprise Management Operations Manager Client because of the following error: No Windows PowerShell Snap-ins are available.

Explanation: This error message appears in the response and grid logs when an operation is executed on the Microsoft System Center Operations Manager 2007 application installed on a 64-bit Windows computer and the <target-64-bit> element is missing from the adapter configuration.

User Response: If the Microsoft System Center Operations Manager 2007 application is installed on a 64-bit Windows computer, ensure that <target-64-bit>true</target-64-bit> is present in the adapter configuration.


Message: Exit code indicates error. Attempting to connect to remote host.. Unable to connect to the remote host: No network provider accepted the given network path.

Explanation: This error message appears in the response and grid logs when an operation is executed with incorrect values for the adapter configuration elements.

User Response: Ensure that the values for all the configuration elements are correct. Also, ensure that the values specified for the <target>, <user-name>, <password>, <target-64-bit>, <scom-working-dir>, <scom-powershell-console-file>, and <is-console-file-remote> adapter configuration elements are correct.

Message: Remote application process ID: 14368. Failed to load Windows PowerShell console file.


Explanation: This error message appears in the response and grid logs when an operation is executed with an incorrect value for the <scom-powershell-console-file> configuration element.

User Response: Ensure that the <scom-powershell-console-file> adapter configuration element contains the correct path for the PowerShell console file. Also, ensure that the values specified for the <target>, <user-name>, <password>, <target-64-bit>, <scom-working-dir>, <scom-powershell-console-file>, and <is-console-file-remote> adapter configuration elements are correct.


Message: Exit code indicates error. Attempting to connect to remote host...Initialising rctrlx server component...

Explanation: This error message appears in the response and grid logs when an operation is executed with an incorrect value for the <scom-working-dir> configuration element.

User Response: Ensure that the <scom-working-dir> adapter configuration element contains a correct path for the Microsoft System Center Operations Manager 2007 working directory. Also, ensure that the values specified for the <target>, <user-name>, <password>, <target-64-bit>, <scom-working-dir>, <scom-powershell-console-file>, and <is-console-file-remote> adapter configuration elements are correct.


Message: AdapterManager: ADAPTER_MANAGER: error occurred updating adapter configuration for SCOMActor.. stopping adapter.

Explanation: This error message appears in grid logs when the value for the <is-console-file-remote> configuration element is incorrect. The adapter then moves to a fault state.

User Response: If the Microsoft System Center Operations Manager 2007 application and the peer are on the same computer, ensure that the value for the <is-console-file-remote> element is false. Otherwise, ensure that the value for the <is-console-file-remote> element is true.


Message: BaseMailMonitorAdapter : ::getFolder() Error :Connect failed. or folder not found or Unable to get initial count of messages on server.

Explanation: This error message appears in the grid logs of the Microsoft System Center Operations Manager 2007 monitor adapter when the value for the <target> configuration element is incorrect. In other words, an exception occurs when connecting to the mail server target.

User Response: Ensure that the <target> adapter configuration element contains the correct mail server target. Also, ensure that the values specified for the <port>, <user-name>, <password>, <javamail-debug>, <email-address>, and <protocol> adapter configuration elements are correct.


Message: MailMonitorAdapterConfig: Exception occurred in Adapter SCOM.

Explanation: This error message appears when the Microsoft System Center Operations Manager 2007 monitor adapter is enabled using an incorrect value for the <protocol> configuration element.

User Response: Ensure that the value of <protocol> configuration element is POP3. Also, ensure that the values specified for the <target>, <port>, <user-name>, <password>, <javamail-debug>, and <email-address> adapter configuration elements are correct.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*