Managing BMC ProactiveNet events in the BMC ProactiveNet Cell environment
An event generated in BMC ProactiveNet creates an event in BMC Event Manager, if the Send event to BMC Event Manager option is selected in the Add event Rule (Page3/3): Action Information for Event Rule screen. BMC ProactiveNet events based on abnormalities also create BMC ProactiveNet Cell events. The severity of predictive events is changed to Warning before the system creates the BMC ProactiveNet Cell Event. The description for the BMC ProactiveNet Cell Events created out of BMC ProactiveNet events based on Abnormalities and Predictive events are prefixed with the words "Abnormal" and "Predictive" respectively, to distinguish them from other BMC ProactiveNet events. When the event is closed in BMC ProactiveNet, the corresponding BMC ProactiveNet Cell Event also gets closed. Ensure that BMC Impact Solution is installed to integrate BMC ProactiveNet and BMC Event Manager.