Probable cause analysis in a scalable deployment environment
In a scalable deployment environment, events are propagated from the local BMC ProactiveNet servers to a central BMC ProactiveNet Server. If you want to perform probable cause analysis on all the events in the environment, probable cause analysis must be performed on the central BMC ProactiveNet Server.
The following figure illustrates how events are propagated in a scalable environment.
Event propagation in a scalable environment
Limitations of probable cause analysis in a scalable environment
Data for the intelligent events on the local servers is not propagated to the master BMC ProactiveNet Server. This causes the propagated intelligent events to be treated as external events. This data loss causes probable cause analysis on the master BMC ProactiveNet Server to lose accuracy because no data correlation is available on the master BMC ProactiveNet Server.