Upgrading BMC ProactiveNet Server 9.0.xx or 9.5.xx to 9.6.00 on Microsoft Windows
This section explains how to upgrade BMC ProactiveNet Server 9.0.xx or 9.5.xx to 9.6.00 on Microsoft Windows.
Upgrading BMC ProactiveNet Server on Microsoft Windows
To upgrade the BMC ProactiveNet Server, perform the following steps:
- Access the installation program by using one of these methods:
- DVD — Insert the installation DVD. In the <installLocation>\Windows directory, open the BPPMServer\Disk1 folder.
- BMC Software EPD website (http://webapps.bmc.com/epd) — For more information about downloading the BMC ProactiveNet software, see Downloading-the-installation-files.
- Extract the contents of the zipped distribution file to an appropriate directory on the computer where the BMC ProactiveNet Server is upgraded.
- Open the install.cmd file with the Run as administrator option.
- On the Welcome page, click Next.
On the license agreement page, select I agree to the terms of the license agreement, and click Next.
The upgrade routine checks the system to see that it meets the upgrade prerequisites. It also checks for a current installation of BMC ProactiveNet Server 9.0.xx or 9.5.xx. It displays any errors that it discovers. You can correct them and then return to the upgrade sequence.
If your server is a standalone BMC ProactiveNet Server or a BMC ProactiveNet Central Server, perform the following step:
On the Configuring BMC ProactiveNet Central Monitoring Base Repository page, provide the following details, and click Next:
Source Directory — BMC ProactiveNet Central Monitoring Repository base file, 9.6.00_base-yyyymmdd-hhmmss.zip, where yyyymmdd-hhmmss is the date and time of the repository image. Download repository files from the BMC Electronic Product Distribution (EPD) facility or copy the files from the installation kit.
- Destination Directory — Directory to install the BMC ProactiveNet Central Monitoring Repository
If you have a 9.0 Central Server without Central Monitoring Administration and you upgrade to a 9.6 Central Server that has Central Monitoring Administration, the Central Server will not contain the 9.0 Central Monitoring Repository contents. The repository will contain only the 9.6 repository contents after the upgrade. Hence, BMC recommends that when upgrading a 9.0 Central Server without Central Monitoring Administration to a 9.6 Central Server with Central Monitoring Administration, specify the 9.0 repository in the Source Directory field. After the upgrade is complete, run the pw-repository-update command with the 9.6 repository as an argument. This will ensure that the repository contains both the 9.0 and 9.6 repository contents.
On the Configuring KB Migration Path page, if you have already migrated customized KB definitions to the new standard 9.6.00 KB, select Yes, and browse to the path of the customized KB directory.
The file path should follow this hierarchy structure:
\topLevelDirectory\mergedKB\server\etc\cellName, where \server\etc\cellName is the standard subdirectoryDuring the upgrade, the routine copies the KB under the \mergedKB\server\etc\cellName path and overwrites the KB in the default installationDirectory\pw\server\etc\cellName path.
On the Installation Preview page, click Install.
- Click Next.
On the Installation Summary window, if you want to view the installation logs, select View Logs. If you want to exit the installation wizard, click Done.
Related topic