Installing in the interactive mode
After your prepare the environment for installation, use the Stack Manager tool to install the TrueSight Automation Console database and the application components.
You can also install the product components from a command line. See Installing-silently.
Build numbers
If you have multiple images of the Stack Manager tool available on the host, BMC recommends that you provide the exact version and build number depending on the version that you want to install.
Version | Build number | Details |
---|---|---|
22.4 | 2365 | The TrueSight Automation Console installer |
Installing the Stack Manager tool
Open a terminal and SSH into the host where you have set up the local registry, and run the following command to install the Stack Manager tool.
docker run -it --rm --network=host 127.0.0.1:5000/bmcsoftware/truesight-stack-managerHere, 127.0.0.1:5000 is the host:port of the local registry that contains the Automation Console images.
You are prompted to specify a location to install the product.Enter a username and password.
Enter a location or continue with the default /opt/bmc location. The Stack Manager tool is installed at the specified location.
You can now continue with installing the database and the application.
Installing the database
By default, PostgreSQL database is installed with the product. However, BMC recommends that you do not use the containerized DB for your production environments. Use an external PostgreSQL database instead.
On the host where the Stack Manager tool is installed, run any of the following commands to start installing the database.
<stackmanager-install-dir>/stackmanager install --deployment=databaseor
<stackmanager-install-dir>/stackmanager install --deployment database- Verify whether the default Docker registry details are accurate and press Enter to continue.
The End User License Agreement is displayed. - Read, and type y to continue with the installation.
After accepting the license agreement, you must provide the values that match your environment (for external database) or accept the default values:
Field
Default value
Notes
Docker network subnet prefix
-
Note: Ensure that the subnet prefix does not conflict with the subnet CIDR or the IP address (172.xx.0.0/16) of your datacenter for the docker0 (docker network adapter/ bridge).
The IP address can be set to either a single octet (For example, 192 which will create the docker networks as 192.X.X.X and so on) or two octets (For example, 192.112 which will create docker networks as 192.112.X.X and so on). This value is used to create internal docker network (application and data network) for container communications and is not visible outside the host machine.
To view the current docker settings, run the docker network inspect bridge command.
Alternatively, if you have created a daemon.json configuration file after setting up Docker, verify the current settings in the file.
For example, go to cat /etc/docker/daemon.json
The file shows the current setting as { "bip": "172.17.0.1/16" }.Port number for PostgreSQL server
5432
Do not change the default port number.
PostgreSQL Admin username
postgres
PostgreSQL Admin password
-
PostgreSQL database installation is complete.
To verify whether the installation is successful, run the following command:
<stackmanager-install-dir>/stackmanager status --deployment=databaseThe following status is displayed.
Components status for database:
Name Container Name Version Status
---- -------------- ------- ------
PostgreSQL database-infra-ext-postgres 14-alpine running
Now that you have successfully installed the database, you can begin installing the application.
Installing the Automation Console application
Install the application after successfully installing the database.
On the host where the Stack Manager tool is installed, run any of the following commands to start installing the application.
./stackmanager install --deployment=tsac+or
./stackmanager install --deployment tsac+If installing the application on a host where containerized database is installed, the installer will confirm whether the database is already installed.
If using an external database (containerized or non-containerized), the installer asks for the additional inputs during application installation. The End User License Agreement is displayed.- Read, and type y to continue with the installation.
After accepting the license agreement, you must provide the values that match your environment or accept the default values:
Field
Default value/notes
Docker network subnet prefix (The installer prompts for this field only if a containerized or an external database is installed on a different host.)
Ensure that the subnet prefix does not conflict with the subnet CIDR or the IP address (172.xx.0.0/16) of your data center for the docker0 (docker network adapter/ bridge).
The IP address can be set to either a single octet (For example, 192 which will create the docker networks as 192.X.X.X and so on) or two octets (For example, 192.112 which will create docker networks as 192.112.X.X and so on). This value is used to create internal docker network (application and data network) for container communications and is not visible outside the host machine.
To view the current docker settings, run the docker network inspect bridge command.
Alternatively, if you have created a daemon.json configuration file after setting up Docker, verify the current settings in the file.
For example, go to cat /etc/docker/daemon.json
The file shows the current setting as { "bip": "172.17.0.1/16" }.This field is required when you install the database and application on separate hosts.
Fully-qualified domain name or IP address of the PostgreSQL server installed in the previous step
BMC recommends that you do not use the containerized DB for your production environments. Use an external PostgreSQL database instead.
Port number of the PostgreSQL server
5432. This field is required when you install the database and application on separate hosts.
Password for the PostgreSQL Admin user 'postgres':
Name of the database
tsac_database
New username for the database
tsac_database_user
Password for the new database user
-
PostgreSQL tablespace
tsac_tablespace
Directory for the system tablespace on the PostgreSQL server
- For containerized PostgreSQL server installed by the StackManager, the default directory, which is not configurable, is: /var/lib/postgresql/data/tsac_tablespace - For an external non-containerized PostgreSQL database, provide a different database directory.
Automation Console port number
10443
- To configure the connector based on your requirement, select one of the following options:
- TrueSight Server Automation
- TrueSight Network Automation
- Configure both the connectors (Default)
If you choose to configure the TrueSight Server Automation connector, enter 1 and provide the following values:
Field
Default values/Notes
TrueSight Server Automation hostname
Fully-qualified domain name or IP address of TrueSight Server Automation
TrueSight Server Automation port number
9843
TrueSight Server Automation protocol
https
TrueSight Server Automation admin role name
BLAdmins
TrueSight Server Automation Service Account username
BLAdmin
TrueSight Server Automation password for the Service Account user
TrueSight Server Automation role name for the Service Account user
BLAdmins
TrueSight Server Automation login authentication type for the Service Account user
SRP Valid values: SRP, Domain
Do you want to configure support for RSSO authentication (y/n)
If using BMC Remedy Single Sign-On for TrueSight Server Automation, specify y.
If not, specify n.
Enter the RSSO Server URL
If specified y in the previous field, enter the BMC Remedy Single Sign-On URL in a fully-qualified domain name format.
If you choose to configure TrueSight Network Automation connector, enter 2 and then provide the values that match your environment.
Field
Default values/Notes
TrueSight Network Automation host name
Fully-qualified domain name or IP address of TrueSight Network Automation
TrueSight Network Automation port number
443
TrueSight Network Automation protocol
Valid values: http, https (default)
TrueSight Network Automation realm name
Default
TrueSight Network Automation Service Account user name
sysadmin
TrueSight Network Automation password for the Service Account user
If you want to configure both the connectors, enter 3 and then provide the values described for the TrueSight Server Automation and TrueSight Network Automation connectors.
After all the details are provided, the Stack Manager installs the application.
To verify whether the installation is successful, run the following command:
./stackmanager status --deployment=applicationThe following status is displayed.
ExampleName Container Name Version Status
---- -------------- ------- ------
Activity Log service truesight-app-activity-log-service 22.4.00.192 running
Catalog service truesight-app-catalog-service 22.4.00.1423 running
Connector Service truesight-connectors-service 22.4.00.2603 running
Data Refresh Worker truesight-app-drw 22.4.00.605 running
Discovery OnPrem Connector truesight-common-discovery-onprem-connector 22.4.00.418 running
Exceptions-service truesight-common-exceptions-service 22.4.00.894 running
ITIL Service truesight-common-itil 22.4.00.766 running
Identity Management Service truesight-identitymanagement-service 22.4.00.1346 running
Login service truesight-common-login 22.4.00.1298 running
Nginx truesight-app-nginx 22.4.00.1257 running
Organization Service truesight-organization-service 22.4.00.590 running
Patch Manager portal truesight-app-patch-manager-portal 22.4.00.10248 running
Patch Manager service truesight-app-patch-manager-core 22.4.00.1993 running
Platform Portal truesight-platform-portal 22.4.00.1693 running
Policy service truesight-app-policy-service 22.4.00.2064 running
Redis truesight-infra-ext-redis 22.4.00.776 running
Redis-common truesight-infra-ext-redis-common 22.4.00.776 running
Resource service truesight-common-resource-service 22.4.00.1017 running
TSNA Connector truesight-common-tsna-connector 22.4.00.1451 running
TSO Connector truesight-common-tso-connector 22.4.00.460 running
TSSA Connector truesight-common-tssa-connector 22.4.00.1140 running
Tenable Connector truesight-common-tenable-connector 22.4.00.1413 running
Tenant Onboarding Utility truesight-common-tenant-onboarding-utility 22.4.00.673 running
Users Service truesight-users-service 22.4.00.635 running
configurations-service truesight-configurations-service 22.4.0.385 running
rsso-portal truesight-rsso-portal 22.4.00.421 running
workmanager-service truesight-workmanager-service 22.4.00.729 running
Where to go next?
Now that you have installed the product successfully, administrators can start setting up the application for your patch, vulnerability, or compliance management needs. You can start using its features based on your role and requirements.
If you want to integrate with BMC Discovery to identify discovered assets, and TrueSight Orchestration to enable change automation, configure the connectors. For details, see Managing-connectors.