Establishing a standard device BCV pair
- Access the EMC Objects panel, as described in Accessing-the-SSI-monitor.
On the EMC Objects panel, type 2 (Establish) in the selection field next to the standard device for which you want to establish a pair and press Enter.
The EMC TimeFinder device selection subpanel (the following figure) is displayed. It lists all available BCVs and indicates the device that was last established as the BCV in the Information field.
EMC TimeFinder device selec Row 1 to 24 of 192
Select a single BCV device for Establish,
'S' or '/', then press Enter.
S Addr DNum IVolser Information
570E 010E
570F 010F Last Established BCV
5710 0110
5711 0111
5712 0112
5713 0113
571E 011E
Command ===>
F1=Help F4=All F5=None F7=Bkwd F8=Fwd
F12=Cancel(PTF BPE0482 applied)
EMC TimeFinder device selec Row 1 to 24 of 192
Select a single BCV device for Establish,
'S' or '/', then press Enter.
S Addr SymDevNo IVolser Information
570E 0000010E
570F 0000010F Last Established BCV
5710 00000110
5711 00000111
5712 00000112
5713 00000113
571E 0000011E
Command ===>
F1=Help F4=All F5=None F7=Bkwd F8=Fwd
F12=Cancel- Type / or S in the selection field next to the BCV that you want to associate with the standard device and press Enter.The SSI action response subpanel indicates that the Establish operation has been initialized.
- Press F12 to return to the EMC TimeFinder Objects panel.