Displaying general information about EMC devices


The bottom portion of the EMC Objects panel lists each device that was returned as a result of the selection criteria that you specified.

EMC Objects panel — Individual objects

Select actions on the following EMC TimeFinder objects, then press           
enter.                                                                       

1=Zoom 2=Establish 3=ReEstablish 4=Split 5=Restore 6=IncRestore              
7=HoldBCV 8=ReleaseBCV 9=StartVirtVolSnap A=StopVirtVolSnap                  
S   Addr  DType  Status   Volser  DNum  Type  Sync    PDev  SRDF              
    0BC0  3390   Online   AFXBC0  0602  STD   Yes     0627  No                
    0BC1  3390   Online   AFXBC1  0603  STD   Yes     0628  No                
    0BC2  3390   Online   AFXBC2  0604  STD   Yes     0629  No                
    0BC3  3390   Online   AFXBC3  0605  STD   Yes     062A  No                
    0BC4  3390   Online   AFXBC4  0606  STD   Yes     062B  No                
    0BC5  3390   Online   AFXBC5  0607  STD   Yes     062C  No                
    0BC6  3390   Online   AFXBC6  0608  STD   Yes     062D  No                
    61B1  3390   Offline          10DD  VVD   No      0AD5  No                
    61B2  3390   Offline          10DE  VVD   No      0A5A  No                
    61B4  3390   Offline          10E0  VVD   No      0A58  No

(PTF BPE0482 applied)

Select actions on the following EMC TimeFinder objects, then press           
enter.                                                                       

1=Zoom 2=Establish 3=ReEstablish 4=Split 5=Restore 6=IncRestore              
7=HoldBCV 8=ReleaseBCV 9=StartVirtVolSnap A=StopVirtVolSnap                  
S   Addr  DType  Status   Volser  SymDevNo  Type  Sync    PDev      SRDF              
    0BC0  3390   Online   AFXBC0  00000602  STD   Yes     00000627  No                
    0BC1  3390   Online   AFXBC1  00000603  STD   Yes     00000628  No                
    0BC2  3390   Online   AFXBC2  00000604  STD   Yes     00000629  No                
    0BC3  3390   Online   AFXBC3  00000605  STD   Yes     0000062A  No                
    0BC4  3390   Online   AFXBC4  00000606  STD   Yes     0000062B  No                
    0BC5  3390   Online   AFXBC5  00000607  STD   Yes     0000062C  No                
    0BC6  3390   Online   AFXBC6  00000608  STD   Yes     0000062D  No                
    61B1  3390   Offline          000010DD  VVD   No      00000AD5  No                
    61B2  3390   Offline          000010DE  VVD   No      00000A5A  No                
    61B4  3390   Offline          000010E0  VVD   No      00000A58  No

(SPE2110)

Select actions on the following EMC SCF/TimeFinder objects, then        
press enter.                             
                              
1=Zoom    2=Establish  3=ReEstablish 4=Split                            
5=Restore 6=IncRestore 7=HoldBCV     8=ReleaseBCV                       
S   Addr.  DType  Status   Volser  SymDevNo  Type  Sync  PDev      SRDF  
    0C00  3390   Online   EM0C00  00000049  STD   No    None      No    
    0C01  3390   Online   JVER07  0000004A  STD   No    None      No    
    0C10  3390   Online   SRDF01  00000059  STD   No    None      Source


The following table describes the information available on the EMC TimeFinder Objects panel for each device.

General information for individual EMC TimeFinder objects

Field

Description

S

Selection column that allows you to perform actions on the selected device

Addr.

The address of the device

(SPE2110)

A five-digit hexadecimal value can be displayed

DType

The device type of this device

Status

The current status of the device—online or offline

Volser

The volume serial number of this device

DNum or (PTF BPE0482 applied) SymDevNo

The device number or (PTF BPE0482 applied) Symmetrix (internal) device number of the device

This number is specific to a hardware unit.

Type

The type of Symmetrix volume—standard, BCV, or Virtual Volume (VVD)

Sync

Whether the device is synchronized

This field can also display whether a device is in held status by displaying the term Held. If the device is held, no other TimeFinder operations can be performed against the device until the device is released. However, snapshots can be performed by using this device. It will be released for that purpose.

PDev

The device number of a paired device

This number will point to the BCV or the STD device number for a mirror connection. The value in this field will be NONE if a STD device is not currently synchronized or if a BCV has never been synchronized. Otherwise, the field will display the last paired device number.

SRDF

Whether this device has an SRDF defined and, for SRDF devices, whether the SRDF is destination or source



 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

SNAPSHOT UPGRADE FEATURE for DB2 6.2