Tape data set filtering
Select Tape Data Set Filtering to advance to the data entry panel that enables you to:
Specify any or all of the parameters described in the following table by using the tape filtering dialogs
Use the OP fields to set comparison operators for the values that you enter. Most non-numeric or single entry fields allow masking and stacking (multiple entries) of values separated by a comma. Some fields have two sets of OP and value entry fields. These fields allow for exclusions and ranges.
- Use the SVOSPARM member containing FLST parameters described in the FLST parameters in SVOSPARM member SMFT31xx that can be used to filter data for the Tape management Data Set Details by DSN view (TDSDD) in conjunction with parameters in the tape data set filtering dialog or on its own.
Tape data set filtering parameters
Parameter | Description | Masking allowed | Multiple entries |
---|---|---|---|
Application Name | Filters on Application Name or mask | + | + |
DSN | Filters on the data set name or mask (MYDSN or MYDSN/) or list (MYDSN/,MYDSN2/...) | + | + |
Volume | Filters on the name of the volume or volume list (vol123,vol2/,vol/) | + | + |
Location | Filters on the tape data set location as determined by the Tape Management Software | + | + |
ATL Library | Filters on the name of an Automated Tape Library (ATL) | + | + |
VTS Library | Filters on the name of a Virtual Tape System (VTS) library | + | + |
Expiration Date Type | Filters on the expiration date type to select Valid values are:
The following CA-1 EXPDT values are available with EXPTYPE=K:
| + |
|
Stacked | Filters on whether a tape data set with a file sequence number of 2 or more is selected Valid values are: Y - Yes N - No |
|
|
Cataloged | Filters on whether a cataloged tape data set is selected Valid values are: Y - Yes N - No |
|
|
Multi-Volume | Filters on whether a tape data set with a volume sequence number of 2 or more is selected Valid values are: Y - Yes N - No |
|
|
In ATL Library | Filters on whether a tape data set in a Automated Tape Library (ATL) is selected Valid values are: Y - Yes N - No |
|
|
In VTS Library | Filters on whether a tape data set in a Virtual Tape System (VTS) is selected Valid values are: Y - Yes N - No |
|
|
Allocation Size | Filters on the allocation size of the data set in KBs |
|
|
Last Read Date | Filters on the last read date of the data set in yyyymmdd format |
|
|
Last Write Date | Filters on the last write date of the data set in yyyymmdd format |
|
|
Last Referenced Date | Filters on the last referenced date of the data set in yyyymmdd format |
|
|
Expiration Date (EXPDT) | Filters on the expiration date for the data set in yyyymmdd format |
|
|
Expiration Type Number | Filters on the numerical value in the expiration date field of a tape data set in nnnnn format Valid values are 0-99999. |
|
|
Days Since Last Read | Filters on the number of days since the data set was last read The system calculates this number by subtracting the last read date from the tape scan date. Valid values are 0-99999. |
|
|
Days Since Last Write | Filters on the number of days since the data set was last written The system calculates this number by subtracting the last write date from the tape scan date. Valid values are 0-99999. |
|
|
Days Since Last Referenced | Filters on the number days since the data set was referenced Valid values are 0-99999. |
|
|
Adjusted Days Since Last Read | Filters on the calendar-adjusted number of work days since the data set was last read The system calculates this number by subtracting the calendar-adjusted last read date from the tape scan date. Valid values are 0-99999. |
|
|
Adjusted Days Since Last Write | Filters on the calendar-adjusted number of work days since the data set was last written The system calculates this number by subtracting the calendar-adjusted last write date from the tape scan date. Valid values are 0-99999. |
|
|
Adjusted Days Since Last Referenced | Filters on the number of days since the data set was referenced Valid values are 0-99999. |
|
|
SMFT31 Member Name | Contains FLST statements to be used in addition to the dialog parameters For more information, see FLST-filtering-for-views. |
|
|
SMS Management Class | Filters on SMS Management Class Name or mask | + | + |
SMS Storage Class | Filters on SMS Storage Class Name or mask | + | + |
FLST parameters in SVOSPARM member SMFT31xx that can be used to filter data for the Tape management Data Set Details by DSN view (TDSDD)
FLST Parameter | Short Description |
---|---|
DSN | DSNAME | Data set name |
DSN1 | HLQ | Node 1 | High-level qualifier |
DSN2 | Node 2 |
DSN3 | Node 3 |
DSN4 | Node 4 |
DSN5 | Node 5 |
DSN6 | Node 6 |
DSN7 | Node 7 |
DSN8 | Node 8 |
LLQ | Low-level qualifier |
VOL | VOLSER | Volume serial number |
BLKSIZE | Block size |
SIZE | Allocation size in K |
LREF | Last referenced date |
REFAGE | Days since last referenced |
CALAGE | Calendar adjusted days since last referenced |
CREATEDATE | Creation date |
CREATEDAGE | Days since creation |
CREATEDCAGE | Calendar adjusted days since creation |
LREADDATE | Last read date |
LREADAGE | Days since last read |
LREADCAGE | Calendar adjusted days since last read |
LWRITEDATE | Last write date |
LWRITEAGE | Days since last write |
LWRITECAGE | Calendar adjusted days since last write |
NUMBLKS | Block count |
CATLGTDS | Cataloged tape data sets |
STACKDS | Stacked data sets |
MULTIVOL_DS | Multi-volume data sets |
IN_ATL_LIB | In ATL Library |
IN_VTS_LIB | In VTS Library |
ATL_LIBNAME | ATL Library name |
VTS_LIBNAME | VTS Library name |
TAPELOC | Tape location |
EXPTYPE | Expiration type |
TAPE_EXPDT | Expiration date (YYYY/MM/DD) |
EXPTYPENUM | Expiration type number (nnnnn) |
APPL | Application name |
SMSGROUP | SMS storage group |
MGMTCLAS | Management class |