ACONCICS=ONLY

The connection facility gives the AutoConnect facility full control of connection decision.

Manually created static and dynamic target definitions are ignored and a BBI-SS directive is optional.

ACONCICS=ONLY requires the least manual setup and is recommended for the following situations:

  • there is only one MainView for CICS BBI-PAS in an LPAR

  • there is multiple MainView for CICS BBI-PASs in an LPAR but it does not matter to which PAS the CICS is connected

  • there is a requirement to move CICS from one LPAR to another


If you have existing static and dynamic target definitions and you want to continue to use them, then the ACONCICS=YES specification is highly recommended.  If you do not have existing static or dynamic target definitions, then ACONCICS=ONLY is highly recommended.   


If you specify ACONCICS=ONLY or ACONCICS=YES with no static or dynamic target definitions, a CASID=xxxx value must be specified in BBISSPxx, and a PAS connection to that CAS is required.

If you are running MainView AutoOPERATOR for CICS and using ACONCICS=ONLY or ACONCICS=YES with no static or dynamic target definition, all CICS commands that can be used in MainView AutoOPERATOR rules and execs are dependent, which means they will not be available until the CICS region target has established communications with the BBI-SS PAS.

Was this page helpful? Yes No Submitting... Thank you