Messages XS7200 through XS7299

This group includes messages for the BMC AMI Ops Infrastructure product.

Oops, it seems that you need to place a table or a macro generating a table within the Table Filter macro.

The table is being loaded. Please wait for a bit ...

NumberDescription
XS7210E

SERVICE ROUTINE ABENDED


Explanation: A service scheduled in the IMS/VS address space failed. A LOGREC record is produced.

User response: Contact BMC Software Customer Support with a copy of the EREP-formatted software record.

XS7211E

DUMP IN PROGRESS FOR SERVICE


Explanation: An service scheduled to the IMS address space failed and an BBI formatted dump is scheduled to be taken. A formatted dump will be taken.

User response: No action is required.

XS7212I

RECOVERY COMPLETE FOR SERVICE


Explanation: A service failed and retry will be attempted. Attempt retry.

User response: No action is required.

XS7213E

LOOP DETECTED IN SERVICE ROUTINE


Explanation: A service scheduled in the IMS/VS address space or BBI/SS address space exceeded 30 seconds in task execution time. The service routine may be in a loop. A user ABEND U1213 will be forced in the service routine, the PSW points to X'00010203'.

User response: Contact BMC Software Customer Support with a copy of the EREP-formatted software record and the BBI formatted dump.

XS7214E

CONTROL BLOCK ERROR - U3611 FOLLOWS


Explanation: After a recoverable error, the ESTAE routine could not find the correct save area chain for the function in error. A U3611 ABEND ends the partner session task.

User response: Contact BMC Software Customer Support.

XS7215I

BBI SOFTWARE RECORD LOGGED TO LOGREC


Explanation: A service scheduled in the target address space ABENDed. A software logrec is logged to SYS1.LOGREC.

User response: Contact BMC Software Customer Support with a copy of the EREP-formatted software record.

XS7216E

BBI/XS HAS DETECTED A LOGIC ERROR - NO XSM


Explanation: An error was detected when a EXEC was dequeued from the XSM queue. The EXEC is not processed and a message is sent to the originator.

User response: Contact BMC Software Customer Support with the relevant error information.

XS7218E

INVALID AMP DETECTED - CREATING NEW AMP


Explanation: An AMP was probably clobbered by a freemain. A new AMP will be created to replace the damaged AMP.

User response: Notify BMC Software Customer Support so that possible diagnostics may be taken.

XS7218E

INVALID AMP DETECTED - CREATING NEW AMP


Explanation: An AMP was probably clobbered by a freemain. A new AMP will be created to replace the damaged AMP.

User response: Contact BMC Support so that possible diagnostics may be taken.