Messages NA9900 through NA9999

This group includes messages for the BMC AMI Ops Automation product.

Oops, it seems that you need to place a table or a macro generating a table within the Table Filter macro.

The table is being loaded. Please wait for a bit ...

NumberDescription
NA9901E

UNABLE TO LOAD 'RRLOAD'


Explanation: An error has occurred in Access/NV, and the error recovery component (load module RRLOAD) was not found in the Access/NV load library. Diagnostics will not be produced for the error that occurred.

User response: Check the customization of BMC AMI Ops Automation Access NV to ensure all product libraries are available.

Note:
BMC AMI Ops Automation was previously known as MainView AutoOPERATOR

NA9902I

STAE EXIT ENTERED FOR RECOVERY ROUTINE


Explanation: During processing, an abend occurred in the Access/NV dump routines. A LOGREC record is produced.

User response: Contact BMC Software Support with a copy of the EREP formatted software record.

NA9903E

ACCESS/NV DIAGNOSTIC DUMP ABORTED


Explanation: During processing, an abend occurred in the diagnostic dump routines. The dump creation was aborted. A record is written to SYS1.LOGREC.

User response: Contact BMC Software Support with a copy of the EREP formatted software record.