Messages BMC50900 through BMC50999

For the Utility products for DB2, this topic explains each message in the designated range.

Oops, it seems that you need to place a table or a macro generating a table within the Table Filter macro.

The table is being loaded. Please wait for a bit ...

NumberDescription
BMC50915E

TABLESPACE 'databaseName.tableSpaceName' USES UNICODE ENCODING SCHEME


Explanation: The table space that was specified (or the table space that contains the table that you specified) for this utility execution uses a Unicode encoding scheme. This version of the utility does not support Unicode encoding schemes.

User response: Specify a table space that does not use a Unicode encoding scheme or specify a table in a table space that does not use a Unicode encoding scheme.

BMC50916E

INDEX 'databaseName.indexName' USES UNICODE ENCODING SCHEME


Explanation: The index that was specified (or an index for the table that was specified) for this utility execution uses a Unicode encoding scheme. This version of the utility does not support Unicode encoding schemes.

User response: Specify an index that does not use a Unicode encoding scheme or specify a table that does not have indexes that use a Unicode encoding scheme.

BMC50920E

text


Explanation: The utility encountered a DB2 feature that it does not support. For some utilities, message BMC50921E follows this message with additional information.

User response: Depending on the unsupported feature and your requirements, take one of the following actions:

  • Change the command syntax or installation options for the utility and resubmit or restart the job.

  • Run the job by using the corresponding IBM utility.

For more information about unsupported features, see the reference manual for the utility that you are running.
BMC50921E

text


Explanation: The utility encountered a DB2 feature that it does not support, or that it supports only with DIRECT NO or by invoking DSNUTILB. This message usually either follows message BMC50920E or is followed by one of the messages in the range BMC50990E through BMC50993E.

User response: See the user responses for the associated messages. If you did not receive one of the associated messages, and you cannot determine the appropriate response to this message, contact BMC Support.

BMC50990E

THIS DB2 FEATURE IS NOT SUPPORTED IN THIS RELEASE OF utility AND THE DSNUTILB OPTION HAS BEEN DISABLED BY USER


Explanation: The utility encountered a DB2 feature that it supports only by invoking DSNUTILB, but the DSNUTILB option is set to NO. Previous messages provide additional information about the specific feature.

User response: Set the DSNUTILB installation or command option to YES and resubmit the job. For more information about DB2 features that the utility supports by invoking DSNUTILB, see the reference manual for that utility.

BMC50991E

THIS DB2 VERSION 8 FEATURE IS NOT SUPPORTED IN THIS RELEASE OF utility


Explanation: The utility encountered a DB2 Version 8 feature that it does not support. Previous messages provide additional information about the specific unsupported feature.

User response: If applicable, change the command syntax for the utility and resubmit or restart the job. For more information about unsupported DB2 features, see the reference manual for the utility.

BMC50992E

THIS DB2 FEATURE IS NOT SUPPORTED IN THIS RELEASE OF utilityName


Explanation: The utility encountered an unsupported Db2 feature. Previous messages provide additional information about the unsupported feature.

User response: If applicable, change the command syntax for the utility and resubmit or restart the job. For more information about unsupported DB2 features, see the BMC AMI Data for Db2 documentation Open link

BMC50993E

THIS DB2 FEATURE IS NOT SUPPORTED IN THIS RELEASE OF utilityName


Explanation:  The utility encountered an unsupported Db2 feature. Previous messages provide additional information about the unsupported feature.

User response: If applicable, change the command syntax for the utility and resubmit or restart the job. For more information about unsupported Db2 features, see the BMC AMI Data for Db2 documentation Open link .

BMC50994E

UTILITY WITH ID utilityID CANNOT BE RESTARTED, LOAD DOES NOT SUPPORT RESTART WITH PRIOR MAINTENANCE


Explanation: The utility was paused or interrupted before applying the SPE2204 maintenance PTF, and restarted after applying the SPE2204 maintenance PTF.

User response: You cannot restart the utility. Term the utility and rerun it.

BMC50999I

text


Explanation: This message is used for multiple messages. Refer to the message text for a description of the message.

User response: Refer to the text for the appropriate user response.

Was this page helpful? Yes No Submitting... Thank you

Comments

  1. Noam Datner

    BMC50900E is not documented: "BMC50900E PROBLEM DETERMINING DB2 VERSION"

    Dec 13, 2021 08:17
  2. Dov Kaiser

    Hi, Noam. It's good to hear from you! I have sent your comment to the writer responsible for this content and will update you when we have documented BMC50900E.

    Dec 13, 2021 08:52
    1. Noam Datner

      Thanks Dov, great hearing from you as well .

      Dec 15, 2021 10:36
      1. Noam Datner

        FYI, I have opened a case for it ,Case 01214175

        Dec 15, 2021 10:39