Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1.

Setting up the MainView environment


Review the required 

MainView

 components and check the status of those components.

Required components

The MainView environment on z/OS includes:

  • MainView Infrastructure
  • MainView products for which you want to develop thresholds

To set up the MainView environment, you use the Installation System on a z/OS system. When you install MVI, you must use the configuration process to customize the components listed in the following table:


Component

Description

CAS

Supplies common services and enables communication within the MainView environment

CASPERM registry

Stores MainView object definitions, such as dynamic threshold definitions

Warning

Note

A CASTEMP registry, which is used for internal processing, is created by MainView automatically.

MVI common registry

Stores information related to MainView Alarm Management, and supports the deployment of definitions to other CASPERM registries on other systems

UIM server

Provides web services support, such as receiving recommended thresholds that are pushed from MainView Threshold Advisor to the mainframe

MainView host server

Provides access to MainView product data

MainView Alarm Management

Monitors performance metrics and produces alarm reports, which can be based on dynamic thresholds

For information about the installation and configuration process, see Installing. For information about managing these MainView components after they are installed, see Administering.

Checking the status of MainView components

MainView threshold management requires certain MainView components to:

  • Collect performance data on the mainframe
  • Make that data available to MainView Threshold Advisor for analysis
  • Push recommended thresholds from MainView Threshold Advisor back to the mainframe
  • Deploy definitions to other systems

Use the following procedure to check the status of the required MainView components.

To check the status of MainView components

  1. Display the CASINFO view (see following figure) by performing one of the following actions:

    • Hyperlink from the CAS Information field on the EZPLEX menu.
    • Type CASINFO on the COMMAND line, and press Enter.

    ddmmmyyyy hh:mm:ss ------ MainView WINDOW INTERFACE (Vv.r.mm) ----------------
    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                            
    >W1 =CASINFO===========CXTST2===*========ddmmmyyyy==hh:mm:ss====PLEXMGR==D====1
     CAS      MVS      CAS  MVLO MVI     Maint   PUT      A COMM     M Exte XCF    
     Name---- Name---- SSID SSID Release Level-- Level--- M Order--- - Secu Group--
     SJSEC610 SJSE     C610 MVSE V6.1.00 BPY9343 PUT1201B Y TXV      Y RACF MV61GRP

    The CASINFO view provides information about the local CAS and the status of the components that are required to support MainView threshold management. To see additional information, scroll the display to the right (see CASINFO view (middle) and CASINFO view (right)).

    CASINFO view (middle)

    ddmmmyyyy hh:mm:ss ------ MainView WINDOW INTERFACE (Vv.r.mm) ----------------
    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                            
    +W1 =CASINFO===========SJSEC610=*========ddmmmyyyy==hh:mm:ss====PLEXMGR==D====1
     CAS      XCF      UIM      UIM   UIM                              P T HostServ
     Name---- Group--- Name---- Port- Version-----                     R R Address-
     SJSEC610 MV61GRP  MV61PUIM 03661 V05.04.00(Build                  Y Y 172.24.4

    CASINFO view (right)

    ddmmmyyyy hh:mm:ss ------ MainView WINDOW INTERFACE (Vv.r.mm) ----------------
    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                            
    +W1 =CASINFO===========SJSEC610=*========ddmmmyyyy==hh:mm:ss====PLEXMGR==D====1
     CAS      HostServer       HostS Path                    
     Name---- Address-----     Port- Name--------            
     SJSEC610 172.24.48.168     5004 /SJSE/tmp/HFS/SJSEC610
  2. Review the following fields on CASINFO to ensure that the required components are available:

    Field

    What to look for

    A M

    A value of Y means MainView Alarm Management is available.

    UIM Name

    The name of the UIM server should be be displayed.

    P R

    A value of Y means the CASPERM registry is available.

    T R

    A value of Y means the CASTEMP registry is available.

    HostServer Address

    The IP address of the MainView host server should be displayed.

    Path Name

    The mount point of the MainView Infrastructure common registry (an HFS or zFS file system) should be displayed.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*