Checking MainView for CICS security

If you encounter security problems with MainView for CICS, check the following items:
  1. Check the SYSLOG and the BBI journal for the following message created during initialization when security through the ESM is in use:

    BCO006I SECURITY DEFINITIONS FOR TYPE=CICS IN USE

    Note

    This message might not be contiguous with other security messages issued; there might be intervening messages.

  2. Check the syntax of the TYPE=CICS statement.

    If the BC0006I message did not show up in the SYSLOG or the BBI journal during BBI-SS PAS initialization, the syntax of the TYPE=CICS statement in the BBSEC member might be incorrect.