All BMC AMI Data for IMS system administration products | All products have the following requirements: |
DELTA IMS DB/DC | MLPA DFSBC000 must reside in a library in the control region that is running DELTA IMS if the following conditions exist: Because modifications to LPA LIB modules apply to all IMS control regions on the CPU, all IMS control regions must use DELTA IMS if the IMS modules are in LPA LIB; otherwise, unpredictable results can occur. To add resources, at least one of each element type must be SYSGENed to the IMS system; otherwise, a user 168 abend will occur when you restart IMS. To use version 5.3 and later, IBM module ICQASLI0 must be in the SYS1.PARMLIB(IKJTSO00) data set member in the AUTHTSF name list, and IBM module DFSTPPE0 (the APPC/IMS TP_PROFILE scheduler exit) must be in a LINKLIST data set.
|
DELTA IMS for DBCTL | If multiple IMS systems share a common DFSBC000 and one or more of the systems do not use DELTA IMS, MLPA DFSBC000 must reside in a library in the control region that is running DELTA IMS. Because modifications to LPA LIB modules apply to all IMS control regions on the CPU, all IMS control regions must use DELTA IMS if the IMS modules are in LPA LIB; otherwise, unpredictable results can occur. To add resources, at least one of each element type must be SYSGENed to the IMS system; otherwise, a user 168 abend will occur when you restart IMS.
|
DELTA IMS VIRTUAL TERMINAL | If multiple IMS systems share a common DFSBC000 and one or more of the systems do not use DELTA IMS, MLPA DFSBC000 must reside in a library in the control region that is running DELTA IMS. Because modifications to LPA LIB modules apply to all IMS control regions on the CPU, all IMS control regions must use DELTA IMS if the IMS modules are in LPA LIB; otherwise, unpredictable results can occur. To add resources, at least one of each element type must be SYSGENed to the IMS system; otherwise, a user 168 abend will occur when you restart IMS. IMS module DFSBC000 cannot reside in any LPA library. ETO must be disabled. Ensure that ETO is not included in the IMSGEN or disable ETO by specifying ETO=N in PROCLIB member DFSPBxxx. To allow multiple sign-ons for a single user ID, the IMS control region SGN parameter value must be G, M, or Z.
|
LOCAL COPY PLUS | No additional requirements apply. |
BMC AMI System Administration for IMS
| Minimum workstation hardware and operating system requirements apply (see UIM server and console requirements). |
BMC AMI System Communication for IMS
| Minimum workstation hardware and operating system requirements apply (see UIM server and console requirements). |
BMC AMI Change Manager for IMS TM
| No additional requirements apply. |
BMC AMI Change Manager for DBCTL
| No additional requirements apply. |
BMC AMI Change Manager Virtual Terminal for IMS
| IMS module DFSBC000 cannot reside in any LPA library. ETO must be disabled. Ensure that ETO is not included in the IMSGEN or disable ETO by specifying ETO=N in PROCLIB member DFSPBxxx. To allow multiple sign-ons for a single user ID, the IMS control region SGN parameter value must be G, M, or Z.
|
BMC AMI Energizer for IMS Connect
|
BMC AMI Energizer for IMS Connect
requires: |
BMC AMI Extended Terminal Assist for IMS
| IMS module DFSBC000 cannot reside in any LPA library. |
BMC AMI Log Analyzer for IMS
| No additional requirements apply. |
BMC AMI Message Advisor for IMS
| No additional requirements apply. |
Comments
Log in or register to comment.