Date: Fri, 29 Mar 2024 00:18:27 -0500 (CDT) Message-ID: <1783117947.29155.1711689507909@bmc1-rhel-confprod1.managed.contegix.com> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_29154_1831350539.1711689507909" ------=_Part_29154_1831350539.1711689507909 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
The following settings in BMC Atrium Single Sign-On control the = timeout behavior in the TrueSight console:
Max Session Time - Time after which your session i= s logged out, even when you are active. The default is 120 minutes; maximum= is 20160 minutes.
Idle Timeout - Time after which your session is lo= gged out if you are inactive or away. The default is 30 minutes; maximum is= 10080 minutes.