Recovering from Errors during a DELTA List Check


If you have selected one-element-at-a-time execution mode with the option of pausing at errors and any elements in the DELTA List encounter errors during the check processing, you will be presented with an Element Error pop-up window (the following figure). This pop-up window indicates the element that encountered the error and describes the error. The pop-up window provides the options of continuing DELTA List processing with the next element or canceling the Check of the DELTA List.

Element Error Pop-up Window

 File  Edit  View  Options  Help                                              
.-----------------------------------------------------------------------------.
|                                Element Error                Row 1 to 1 of 1 |
| Command ===> ____________________________________________ Scroll ===> PAGE |
|                                                                             |
| The DELTA List encountered an element error during check/execute.           |
| Do you wish to continue executing the DELTA List?                           |
| _ 1. Yes, continue executing the DELTA List on the next element             |
|   2. No, cancel execution                                                   |
|                                                                             |
| Element Type: TRANSACT      DELTA List  : DOCRLIST                          |
| Element Name: CTSCMD        DELTA Action: ADD                               |
|                                                                             |
| IMSID  Error Message                                                        |
| ------ -------------------------------------------------------------------  |
| WXC5 BMCDLP186701E Application could not be located                         |
| ***************************** Bottom of data ****************************** |
|                                                                             |
|                                                                             |
|                                                                             |
|                                                                             |
|  F1=Help     F7=Up       F8=Down    F12=Cancel                              |
'-----------------------------------------------------------------------------

 

Fields Available on the Element Error Pop-up Window

Field Name

Description

selection field

Type the option number of your choice for Check processing of the DELTA List. Possible values are:

  • 1 - Yes, continue executing the DELTA List on the next element
  • 2 - No, cancel execution

Element Type

Identifies the type of the IMS system resource element in the DELTA List. Possible values are:

  • APPLCTN - application programs that run under the control of the IMS DB/DC environment
  • TRANSACT - IMS exclusive, IMS Fast Path potential, or IMS Fast Path exclusive transactions
  • DATABASE - a physical database that IMS manages
  • RTCODE route codes
  • TERMINAL IMSGEN-defined terminals
  • LTERM - IMSGEN-defined LTERMs
  • SUBPOOL IMSGEN-defined subpools
  • COMMAND selected IMS operator commands
  • DELTALST a DELTA List nested, or embedded, in the parent DELTA List

Element Name

Identifies the name of the IMS system resource element in the DELTA List

DELTA List

Identifies the DELTA List being checked

DELTA Action

Identifies the DELTA Action taken against the associated IMS system resource element. Possible values are

  • ADD
  • ADD/REVISE
  • REVISE
  • DELETE
  • RELOAD

IMSID

Identifies the IMSID(s) of the IMS system(s) where the element was checked.

Error Message

Identifies the error message for the error encountered by the element.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*