Page tree
    Skip to end of metadata
    Go to start of metadata

    The BMC PATROL for UNIX and Linux 9.13.00.02 patch corrects an issue reported in 9.13.00 version of BMC PATROL for UNIX and Linux. This topic also includes updates provided in this patch and instructions for downloading and installing the patch.

    For information about issues corrected in this patch, see Known and corrected issues.

    Updates in the patch

    This section describes the updates provided in BMC PATROL for UNIX and Linux 9.13.00.02.

    Note

    The Data Collection Manager (DCM) executable version in BMC PATROL for UNIX and Linux 9.13.00.02 is 9.5.00.6069.

    Enhancment in the Swap application class

    The _Total instance of SWAP application class now displays the total value of all devices, and the Summary instance of SWAP application class displays the sum of total value of all devices and main memory values.

    New pconfig variable 

    BMC PATROL for UNIX and Linux now supports a new pconfig variable, externFqdn

    You can use the externFqdn pconfig variable to set MetaFQDN value of remote host instances in the following scenarios so that the hosts are displayed as devices in the BMC ProactiveNet Operations Console. 

    • If DNS is not configured 
    • If nslookup command does not work

    The path and format for externFqdn pconfig variable is as follows:

    "/REMOTE/HOSTS/<<hostname>>/externFqdn"= {REPLACE = "<<FQDN>/<IP Address>>"}

    Example, 

    Replace <<FQDN>/<IP Address>> with xyz.bmc.com/10.10.10.10

    Note

    • You need to add this variable manually per remote host level.

    • You must restart the PATROL Agent after the pconfig value is set.

    Downloading the patch and installation utility

    This section provides the information that you need to download and install the patch from the BMC Electronic Product Distribution (EPD) website. To download the patch and installation utility from the EPD website, perform the following steps:

    1. Create a directory in which to place the downloaded files.

      Note

      On Windows computers, ensure that the directory is only one level into the directory structure. The EPD package creates a directory in the temporary directory when you extract the files, and the directory that contains the installation image should not be in a directory deeper than two levels into the directory structure.

    2. Go to http://www.bmc.com/available/epd.html.
    3. At the logon prompt, enter your user ID and password, and click Submit.
    4. On the Export Compliance and Access Terms page, provide the required information, agree to the terms of the agreements and click Continue.
    5. If you are accessing this site for the first time, create an EPD profile to specify the languages and platforms that you want to see, per the EPD site help; otherwise, skip to step 6.
    6. Verify that the correct profile is displayed for your download purpose.
    7. You can download the installation utility and the product patch using either of the following methods:
    Using Component View
    1. In the Filter Products: field, type BMC PATROL Installation Utility.
    2. Click Go.
    3. In the right pane, click BMC PATROL Installation Utility.

      Note

      You can use BMC PATROL Installation Utility 9.5.00 or later.

    4. In the Version: list, select 9.6.01 and click Go.
    5. In the Products tab, based on the operating system, select the check box next to the files.

      Link titleActual file namePlatform

      BMC PATROL Installation Utility Version 9.6.00 - Windows Only

      ins_WINDOWS_9600.zip

      Microsoft Windows/NT
      BMC PATROL Installation Utility Version 9.6.00 - All UNIX/LINUXins_ALL_9600.tarAll Platforms
    6. To download the selected files, click Download (FTP) or Download Manager:
      • Download (FTP) places the selected items in an FTP directory, and the credentials and FTP instructions are sent to you in an email message.
      • Download Manager enables you to download multiple files consecutively and to resume an interrupted download.
        This method requires a one-time installation of the Akamai NetSession client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum operation is used to verify file integrity automatically.
    7. Click   icon to close the window.
    8. In the Filter Products: field, type BMC PATROL for Unix and Linux.
    9. Click Go.
    10. In the right pane, click BMC PATROL for Unix and Linux.
    11. In the Version: list, select 9.13.00 and click Go.
    12. In the Patches tab, select the check box next to the file. 

      Link titleActual file namePlatform
      PATROL Knowledge Module for Unix v9.13.00.02 Patchpuk_ALL_9130002.zipMicrosoft Windows/NT
      PATROL Knowledge Module for Unix v9.13.00.02 Patchpuk_ALL_9130002.tarSolaris / HP-UX / Linux / AIX
    13. To download the selected files, click Download (FTP) or Download Manager:
      • Download (FTP) places the selected items in an FTP directory, and the credentials and FTP instructions are sent to you in an email message.
      • Download Manager enables you to download multiple files consecutively and to resume an interrupted download.
        This method requires a one-time installation of the Akamai NetSession client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum operation is used to verify file integrity automatically.
    14. Complete the installation procedure described in the Installing the patch section.
    Using Licensed Products View
    1. Click Go To Licensed Products View.
    2. Locate BMC Performance Manager for Servers and expand its entries to show the available version numbers.
    3. Expand BMC Performance Manager for Servers 3.5.00 to show the available components.
    4. Expand BMC PATROL Installation Utility 9.6.01 to show the available files.

      Note

       You can use BMC PATROL Installation Utility 9.5.00 or later.

    5. Select the check box next to the files, based on the appropriate platforms.

      Link titleActual file namePlatform
      BMC PATROL Installation Utility Version 9.6.00 - Windows Onlyins_WINDOWS_9600.zipMicrosoft Windows/NT
      BMC PATROL Installation Utility Version 9.6.00 - All UNIX/LINUXins_ALL_9600.tarAll Platforms
    6. To download the selected files, click Download (FTP) or Download Manager:
      • Download (FTP) places the selected items in an FTP directory, and the credentials and FTP instructions are sent to you in an email message.
      • Download Manager enables you to download multiple files consecutively and to resume an interrupted download.
        This method requires a one-time installation of the Akamai NetSession client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum operation is used to verify file integrity automatically.
    7. Click Product Patches tab.
    8. In the Product Patches tab, expand BMC Performance Manager for Servers and expand its entries to show the available version numbers.
    9. Expand BMC Performance Manager for Servers 3.5.00 to show the available components.
    10. Expand the BMC PATROL for UNIX and Linux 9.13.00 component to show the available files.
    11. Select the check box next to the patches.

      Link titleActual file namePlatform
      PATROL Knowledge Module for Unix v9.13.00.02 Patchpuk_ALL_9130002.zipMicrosoft Windows/NT
      PATROL Knowledge Module for Unix v9.13.00.02 Patchpuk_ALL_9130002.tarSolaris / HP-UX / Linux / AIX 
    12. To download the selected files, click Download (FTP) or Download Manager:
      • Download (FTP) places the selected items in an FTP directory, and the credentials and FTP instructions are sent to you in an email message.
      • Download Manager enables you to download multiple files consecutively and to resume an interrupted download.
        This method requires a one-time installation of the Akamai NetSession client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum operation is used to verify file integrity automatically.
    13. Complete the installation procedure described in the Installing the patch section.

    Installing the patch

    Note

    Before you begin

    You must install the patch on the following computers:

    • Hosts that are running the PATROL Agent
    • Hosts that are running the PATROL Console

    Before you install the patch, complete the following steps:

    1. Stop the PATROL Agent.
    2. Back up the PATROL_CACHE directory.
    3. Delete all BMC PATROL for UNIX and Linux files from the PATROL_CACHE directory.
    4. Back up the PATROL_HOME/lib/knowledge and PATROL_HOME/lib/psl directories.

    To install the BMC PATROL for UNIX and Linux 9.13.00.02 patch

    After you have downloaded the installation utility and patch files, perform the following steps to install the patch:

    1. Extract the installation utility:

      • For Windows, double-click ins_WINDOWS_9600.zip
      • For UNIX, enter tar -xvf ins_ALL_9600.tar

        The contents of the files are extracted into the bmc_products subdirectory.
    2. Extract the patch file:
      • For Windows, double-click puk_ALL_9130002.zip
      • For UNIX, enter tar -xvf puk_ALL_9130002.tar

        The contents of the files are extracted into the bmc_products subdirectory. 

    3. From the bmc_products directory, run the installation utility as appropriate for your operating system:

      • For Windows, double-click setup.exe

      • For UNIX, run setup.sh

    4. Follow the on-screen instructions until the Select Products and Components to Install page is displayed. 

    5. On the Select Products and Components to Install page, select PATROL Knowledge Module for UNIX and Linux - Patch 9.13.00.02.

    6. Follow the on-screen instructions to complete the installation.

      After you complete the installation steps, you can delete the temporary directory and its contents.

     