This section contains information about Service Pack 2 for BMC Server Automation version 8.2.
About Service Pack 2
This service pack includes full installers for all components. You can download the service pack files from the BMC Electronic Product Distribution (EPD) website. The version number shown on EPD is 8.2.02.
Considerations for patch management
If you are using Microsoft Windows, review the following considerations for patch management.
Resolving a potential RSCD Agent installation problem
On version 8.2, if the target system is in a pending reboot state (for example, from a previous patch or other software installation), then the default MSI installer supplied with the agent disallows the installation.
In 8.2 SP2, the PENDINGREBOOTFORCE
flag allows the MSI installer to ignore this state. After confirming that the pending reboot state on the target is not a result of a previous RSCD installation, setting PENDINGREBOOTFORCE=1
ignores the pending reboot state and proceeds with the installation. The following is a sample command line for the MSI installer:
msiexec /I RSCD82-SP2.WIN32.msi /qn REBOOT=ReallySuppress PENDINGREBOOTFORCE=1
Contents of the service pack
The following topics describe the updates included and the problems corrected in this service pack.
Downloading the files
Click here to see the procedure for obtaining the service pack files.
To download files:
Create a directory in which to place the downloaded files.
Go to http://www.bmc.com/available/epd.html.
At the login prompt, enter your user ID and password, and click Submit.
On the Export Compliance and Access Terms page, provide the required information, agree to the terms of the agreements, and click Continue.
If you are accessing this site for the first time, create an EPD profile to specify the languages and platforms you want to see, per the EPD site help; otherwise, skip to step 6.
Verify that the correct profile is displayed for your download purpose, and select the Licensed Products tab.
Depending on your product license, expand the relevant BMC BladeLogic Server Automation Suite or Module node to show the listed versions.
- Expand the relevant version node:
- For the base version, expand the 8.2.00 node.
- For a service pack, expand the relevant 8.2.0x version node.
Under the suite node, expand the BMC Server Automation node for the selected version.
Expand the entry for the relevant platform and language to show its downloadable files.
Select the files you want to download. See Installation programs for BMC Server Automation.
Click Download (FTP) or Download Manager:
Download (FTP) places the selected items in an FTP directory, and the credentials and FTP instructions are sent to you in an e-mail message.
Download Manager enables you to download multiple files consecutively, and to resume an interrupted download if the connection drops. This method requires a one-time installation of the AkamiNetSession Client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum is used to verify file integrity automatically.
Upgrading to the service pack
To upgrade to this service pack, complete the tasks described in the following sections.
Review the supported upgrade paths
Click here to see a list of supported upgrade paths.
Upgrading from this version | Perform these tasks |
---|
Upgrading from version 8.2 SP1 | Complete the following tasks: - Upgrade the Application Server to version 8.2 SP2.
- Run the 8.2 SP2 SQL scripts provided in the 82-SP2-SQL_Update_Scripts.zip file (not the 8.2 SP2 external files). This file is available in the BMC Server Automation 8.2.02 section of EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin), according to the instructions provided for your database type in the readme file in the .zip. This step upgrades the database to a state that is compatible with the 8.2 SP2 Application Server.
|
Upgrading from version 8.2 | Complete the following tasks: - Upgrade the Application Server to version 8.2 SP2.
- Run the Data Migration Manager using the 8.2.02 external files to upgrade the database to 8.2 SP1.
- Run the 8.2 SP2 SQL scripts provided in the 82-SP2-SQL_Update_Scripts.zip file (not the 8.2 SP2 external files). This file is available in the BMC Server Automation 8.2.02 section of EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin), according to the instructions provided for your database type in the readme file in the .zip. This step upgrades the database to a state that is compatible with the 8.2 SP2 Application Server.
|
Upgrading from version 8.1 - 8.1 SP4 | Complete the following tasks: - Upgrade the Application Server to version 8.2 SP2.
- Run the Data Migration Manager using the 8.2.02 external files to upgrade the database to 8.2 SP1.
- Run the 8.2 SP2 SQL scripts provided in the 82-SP2-SQL_Update_Scripts.zip file (not the 8.2 SP2 external files). This file is available in the BMC Server Automation 8.2.02 section of EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin), according to the instructions provided for your database type in the readme file in the .zip. This step upgrades the database to a state that is compatible with the 8.2 SP2 Application Server.
|
Upgrading from version 8.0 GA – version 8.0 SP11 | Complete the following tasks: - Upgrade the Application Server to version 8.2 SP2.
- Run the Data Migration Manager using the 8.2.02 external files to upgrade the database to 8.2 SP1.
- Run the 8.2 SP2 SQL scripts provided in the 82-SP2-SQL_Update_Scripts.zip file (not the 8.2 SP2 external files). This file is available in the BMC Server Automation 8.2.02 section of EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin), according to the instructions provided for your database type in the readme file in the .zip. This step upgrades the database to a state that is compatible with the 8.2 SP2 Application Server.
|
Upgrading from version 7.6 | Complete the following tasks: - Upgrade the Application Server to version 8.2 SP2.
- Run the Data Migration Manager using the 8.2.02 external files to upgrade the database to 8.2 SP1.
- Run the 8.2 SP2 SQL scripts provided in the 82-SP2-SQL_Update_Scripts.zip file (not the 8.2 SP2 external files). This file is available in the BMC Server Automation 8.2.02 section of EPD. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin), according to the instructions provided for your database type in the readme file in the .zip. This step upgrades the database to a state that is compatible with the 8.2 SP2 Application Server.
- Migrate compliance rules and discovery signatures in the database.
|
Review the upgrade sequence
Review the upgrade considerations and the upgrade sequence.
Click here to review the upgrade sequence.
Upgrade at least one Application Server.
Additional upgrades that occur at this point depend on where the Application Server resides:
On a Microsoft Windows computer, an upgrade of the Application Server also upgrades the Network Shell. See Upgrading the Application Server on Windows.
On a Linux or UNIX computer, an upgrade of the Application Server also upgrades all components that were installed as part of the earlier installation of the Application Server. These components can include the Network Shell, the RSCD agent, and the PXE server. See Upgrading the Application Server on Linux and UNIX.
- Upgrade at least one BMC Server Automation Console. See Upgrading the BMC Server Automation Console.
- Migrate the BMC Server Automation database to the current release. See Migrating core BMC Server Automation data.
- If upgrading to a service pack, run a series of SQL scripts (provided with the service pack files) that upgrade the database to the service pack level. See Supported upgrade paths.
- If you are migrating from a pre-8.0 version of BMC Server Automation, migrate compliance rules and discovery signatures. See Migrating compliance rules and discovery signatures.
- If the BMC Server Automation file server resides on a different computer from the Application Server, upgrade the RSCD agent on the computer on which file server resides. The file server and the database must be at the same version before you run BMC Server Automation.
- Confirm that the file server agent is running.
- Upgrade the BMC Server Automation provisioning system. See Upgrading the Provisioning System.
Upgrade the other BMC Server Automation Application Servers, consoles, and RSCD agents in your enterprise (including on any virtual servers). Also upgrade any distributed custom configuration objects.
Run the service pack installers
See the following topics for information about running the specific installers.
Run database migration
After upgrading the application server, you must upgrade the database through the Data Migration Manager. This will upgrade the database to 8.2 SP1.
You can migrate to BMC Server Automation version 8.2 SP2 only from version 7.6 and later versions. If you are running a version earlier than 7.6, you must first upgrade to version 7.6. See the BMC Server Automation Installation Guide for version 7.6 for information about upgrading earlier versions.
When you migrate from earlier product versions to the current product version, you must use BMC BladeLogic Data Migration Manager to perform the migration of core data from your Oracle or SQL Server database.
After completing the database migration, you must run the SQL scripts found in the 82-SP2-SQL_Update_Scripts.zip file, provided on the 8.2 SP2 EPD page. These scripts upgrade the database from 8.2 SP1 to 8.2 SP2. Run these scripts as the BMC Server Automation database owner (as provided to blasadmin). For more detailed instructions, see Running the SQL update scripts
For more information, see Review the supported upgrade paths.
Upgrade the RSCD agents
See the following topics for information about upgrading RSCD agents:
Comments