Page tree

Unsupported content

 

This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.

Skip to end of metadata
Go to start of metadata

This topic lists the out-of-the-box Allocation and Utilization Units of Measurement (UoMs) in BMC Cloud Lifecycle Management (CLM) versions 3.0 and later, their corresponding BMC Capacity Optimization metrics, and supported platforms.

UoM compatibility matrix

The following table serves as a compatibility matrix for Allocation and Utilization type UoMs with their supported provider and platform types.

Allocation and Utilization type UoMs: Compatibility Matrix



Type

Provider
BBSAAMAZON EC2vCLOUD
Platform →
UoM

VMware vShpereCitrix XenServerIBM AIXMicrosoft Hyper-VRHEVBare metal serverAmazon EC2VMware vCD
Allocation


Instance(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
CPU Count(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Allocated Memory GB(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Allocated Storage GB(tick)(tick)(tick)(tick)(tick)(tick)(tick)(tick)
Utilization




Uptime(tick)NANANANANANA(tick)
CPU Avg Usage GHz(tick)(tick)NANANANANA(tick)
Memory Avg Usage GB(tick)(tick)NANANANANA(tick)
Network GB Download(tick)(tick)NANANANANA(tick)
Network GB Upload(tick)(tick)NANANANANA(tick)
Storage Avg Usage GB(tick)(tick)NANANANANA(tick)

Legend:
(tick) denotes a supported (compatible) UoM per provider, per platform.
NA denotes an unsupported (incompatible) UoM per provider, per platform.

Metric mapping with provider and platform types

The following sections list each provider and platform along with their supported UoMs, mapped metrics, BMC Capacity Optimization and CLM versions, and the required connectors.

BBSA - VMware vSphere

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the VMware vSphere platform with a BMC BladeLogic Server Automation (BBSA) provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionCLM Versions
Allocation


Instance(no explicit metric)

 

 

CLM Cloud Services Extractor








 

9.5








 


3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
Utilization




Uptime
UPTIME

 

 

vCenter Extractor Service
+
CLM Cloud Services Extractor 

CPU Avg Usage GHz
CPU_UTILMHZ
Memory Avg Usage GB
MEM_CONSUMED
Network GB Download
NET_IN_BYTE_RATE
Network GB Upload
NET_OUT_BYTE_RATE
Storage Avg Usage GB
TOTAL_DSTORE_USED

BBSA - Citrix XenServer

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the Citrix XenServer platform with a BBSA provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
Allocation


Instance(no explicit metric)

 

 

CLM Cloud Services Extractor

 

 


9.5

 

 

3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
Utilization




Uptime
UPTIME
NANANA
CPU Avg Usage GHz
CPU_UTILMHZ

 

 

XenServer Extractor
+
CLM Cloud Services Extractor 

 

 

 

9.5

 

 

 

3.0 and later

Memory Avg Usage GB
MEM_CONSUMED
Network GB Download
NET_IN_BYTE_RATE
Network GB Upload
NET_OUT_BYTE_RATE
Storage Avg Usage GB
TOTAL_DSTORE_USED

NA denotes an unsupported (incompatible) UoM for the Citrix XenServer platform with a BBSA provider.

BBSA - IBM AIX

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the IBM AIX platform with a BBSA provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
Allocation


Instance(no explicit metric)

 


CLM Cloud Services Extractor

 


9.5

 

 

3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
Utilization




Uptime

 

 

 

NA

 

 



NA





NA

 

 

 

NA

CPU Avg Usage GHz
Memory Avg Usage GB
Network GB Download
Network GB Upload
Storage Avg Usage GB

NA denotes unsupported (incompatible) UoMs for the IBM AIX platform with a BBSA provider.

BBSA - Microsoft Hyper-V

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the Microsoft Hyper-V platform with a BBSA provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
Allocation


Instance(no explicit metric)



CLM Cloud Services Extractor

 

 

9.5

 

 

3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
Utilization



Uptime

 

 

 

NA

 

 



NA


 

 

 

NA

 

 

 

NA

CPU Avg Usage GHz
Memory Avg Usage GB
Network GB Download
Network GB Upload
Storage Avg Usage GB

NA denotes unsupported (incompatible) UoMs for the Microsoft Hyper-V platform with a BBSA provider.

BBSA - RHEV

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the Red Hat Enterprise Virtualization (RHEV) platform with a BBSA provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
AllocationInstance(no explicit metric)

 

 

CLM Cloud Services Extractor

 

 

9.5

 

 

3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
UtilizationUptime

 

 

 

NA

 




NA

 

 

 

 

NA

 

 

 

NA

CPU Avg Usage GHz
Memory Avg Usage GB
Network GB Download
Network GB Upload
Storage Avg Usage GB

NA denotes unsupported (incompatible) UoMs for the RHEV platform with a BBSA provider.

BBSA - Bare metal server

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for Bare metal servers with a BBSA provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
AllocationInstance(no explicit metric)

 

 

CLM Cloud Services Extractor

 

 

9.5

 

 

3.1 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GBNA
UtilizationUptime

 

 

 

NA

 




NA

 

 

 

 

NA

 

 

 

NA

CPU Avg Usage GHz
Memory Avg Usage GB
Network GB Download
Network GB Upload
Storage Avg Usage GB

NA denotes unsupported (incompatible) UoMs for the Bare metal servers with a BBSA provider.

vCLOUD - VMware vCD

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the VMware vCD platform with a vCLOUD provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
AllocationInstance(no explicit metric)

 

 

CLM Cloud Services Extractor

 

 

 

 

 

 

 

9.5

 

 

 

 

 

 

 

3.1.01.01 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
UtilizationUptime
UPTIME

 

 

 

vCenter Extractor Service
+
CLM Cloud Services Extractor  

CPU Avg Usage GHz
CPU_UTILMHZ
Memory Avg Usage GB
MEM_CONSUMED
Network GB Download
NET_IN_BYTE_RATE
Network GB Upload
NET_OUT_BYTE_RATE
Storage Avg Usage GB
TOTAL_DSTORE_USED

AMAZON EC2 - Amazon EC2

The following table shows the metric mapping per connector, BMC Capacity Optimization, and CLM version for the Amazon EC2 platform with an AMAZON EC2 provider.

TypeUoMBMC Capacity Optimization MetricConnectorBMC Capacity Optimization VersionsCLM Versions
AllocationInstance(no explicit metric)

 

 

CLM Cloud Services Extractor

 

 

9.5

 

 

3.0 and later

CPU Count
REQUESTED_CPU_NUM
Allocated Memory GB
REQUESTED_MEM
Allocated Storage GB
REQUESTED_DISK_SIZE
UtilizationUptime






NA




 

NA



 




NA






NA

CPU Avg Usage GHz
Memory Avg Usage GB
Network GB Download
Network GB Upload
Storage Avg Usage GB

NA denotes unsupported (incompatible) UoMs for the Amazon EC2 platform with an AMAZON EC2 provider.

Related topics

Examples of calculations for UoMs supported in Chargeback for BMC Cloud Lifecycle Management

Understanding Chargeback for BMC Cloud Lifecycle Management