In certain pure IPv6 environments, the TrueSight Presentation Server installation completes without any warnings. The core server, index server, and database server processes are listed as not running.

As a workaround, perform the following steps:

  1. Comment the following parameters:
    1. #vm.args.system.26 in the installedDirectory\truesightpserver\conf\services\csr.conf file.
    2. #vm.args.system.18 in the installedDirectory\truesightpserver\conf\services\idxsrv.conf file.
  2. Run the following commands from the installedDirectory\truesightpserver\bin directory to restart the TrueSight Presentation Server:
    tssh server stop
    tssh server start


Was this page helpful? Yes No Submitting... Thank you