Review the e-mail settings on the server target computer to ensure that it is configured to receive e-mail alerts from Infrastructure Management. If it is not, an error or warning message similar to the following is displayed:
Warning: ProactiveNet's e-mail alerts may not work with the current configuration
If this message is displayed, perform the following procedure.
Review the e-mail settings and make any necessary changes, as described in the table below:
E-mail settings required to receive alerts from Infrastructure Management
Setting | Location | Parameter or property to change | Correct format |
---|---|---|---|
Administrator's e-mail address |
| admin_user | Fully qualified e-mail address in the following format:user@company.com |
Sender's e-mail address |
| from_name | Either user oruser@company.com, depending on the valid From address accepted by the SMTP server |
SMTP server hostname or IP address |
| pronet.api.emailer.smtp.host | Fully qualified server hostname or IP address reachable from the BMC TrueSight Infrastructure Management Server host |
SMTP port |
| pronet.api.emailer.smtp.port | Valid port number on which the SMTP server is listening for SMTP requests |
Success
or Failure
message is sent to the administrator's e-mail address and is added to the TestEmail.log file that is located in the same directory as the verification script.
2 Comments
Dony Sheppard
Krutarth Mohakud
Thanks, Dony Sheppard for the feedback. We have updated the page.