Messages BMC202300 through BMC202399

This group includes messages for the BMC AMI Recovery for VSAM product. Many of these messages are related to subsystem processing.

Oops, it seems that you need to place a table or a macro generating a table within the Table Filter macro.

The table is being loaded. Please wait for a bit ...

NumberDescription
BMC202300E

RUV RUVZOBJ text


Explanation: RUV encountered an internal error. The variable text can be one of the following problems:

  • Invalid token

  • Invalid base token

  • Token missing

  • Request out of range

  • Request not supported

  • Method not found

  • Copy / base invalid.


User response: Contact BMC Support.

BMC202301E

RUV DSName dataSetName is not a registered backup.


Explanation: The restore request specified an unregistered backup dataSetName. The restore request was refused.

User response: Specify a registered backup and rerun the job.

BMC202302I

RUV End of data encountered while reading repository.


Explanation: This is a normal condition unless some other error occurred.

User response: To determine what action to take, see any associated messages. Otherwise, no action is required.

BMC202303E

RUV DSName dataSetName is not a registered VSAM file.


Explanation: The restore request specified an unregistered VSAM file dataSetName. The restore request was refused.

User response: Add the VSAM file to the repository and rerun the job.

BMC202304I

RUV record record not found on repository: key (key).


Explanation: This is a normal condition unless some other error occurred.

User response: To determine what action to take, see any associated messages. Otherwise, no action is required.

BMC202305I

RUV Item (item) not found.


Explanation: This is a normal condition unless some other error occurred.

User response: To determine what action to take, see any associated messages. Otherwise, no action is required.

BMC202306E

RUV DSName dataSetName backup is registered but not active.


Explanation: The restore request specified an inactive backup file dataSetName. The restore request was refused.

User response: Select another backup or activate the selected backup.

BMC202307W

RUV Duplicate type record found.


Explanation: A record of the specified type with the same key is already on the repository. This is a normal condition unless some other error occurred.

User response: No action is required.

BMC202308W

RUV Duplicate item (item) found.


Explanation: The indicated item is already present in the record. This is a normal condition unless some other error occurred.

User response: No action is required.

BMC202309E

RUV No current record found.


Explanation: No record currently exists in the repository buffer.

User response: Contact BMC Support.

BMC202310E

RUV Commit is pending.


Explanation: The repository was updated in memory, but no request was made to commit the changes to DASD.

User response: Run the RELEASE REPOSITORY command.

BMC202311E

RUV The update function is not allowed.


Explanation: The repository object is in read-only mode.

User response: Contact BMC Support.

BMC202312E

RUV Time stamp mismatch found in the repository record, RC(returnCode).


Explanation: RUV found conflicting time stamps in the repository record. Multiple concurrent updates to the repository can cause this condition.

User response: Rerun the job. If this does not correct the problem, contact BMC Support.

BMC202313E

RUV Other repository error, RC(returnCode).


Explanation: RUV received an unexpected return code in response to a request for repository I/O.

User response: Contact BMC Support.

BMC202314E

RUV Insufficient access authority. RS(reasonCode).


Explanation: You do not have sufficient authority for the requested operation. Access to the repository requires at least UPDATE authority for the repository data sets.

User response: Contact your RACF administrator to obtain the required authority.

BMC202315E

RUV Invalid record length; length is too short.


Explanation: Repository records must be at least 64 bytes long.

User response: Contact BMC Support.

BMC202316E

RUV Invalid record length; length is too long.


Explanation: Repository records must be shorter than 16 MB.

User response: Contact BMC Support.

BMC202317E

RUV Invalid record type code (type).


Explanation: The indicated type is not valid for a repository record.

User response: Contact BMC Support.

BMC202318E

RUV Invalid item length length; length is less than sixteen.


Explanation: The repository item is too short. All items must be at least 16 bytes long.

User response: Contact BMC Support.

BMC202319E

RUV Invalid item length length; length is too long.


Explanation: The repository item is too long. Unstructured items (format 0) must be less than 32 KB. Structured items (formats 1 and 2) must be less than 16 MB.

User response: Contact BMC Support.

BMC202320E

RUV Invalid item code itemCode found.


Explanation: The repository item code is invalid. Repository item codes consist of four uppercase, alphabetic characters.

User response: Contact BMC Support.

BMC202321E

RUV Invalid item length length; length is not a multiple of eight.


Explanation: The repository item length is invalid. Repository item lengths must be a multiple of eight.

User response: Contact BMC Support.

BMC202322I

RUV No Active rule set on repository. Will use $DUMMY. ssid


Explanation: No previously active rule set exists to be reactivated. This is not an error, but RUV cannot protect your data without an active rule set.

User response: Activate a rule set. RUV will save the name in the repository and automatically reactivate it during initialization.

BMC202323E

RUV Return from subsystem, RC(returnCode) SPLRC(SPLRC) RPLFDBWD(RPLFDBWD).


Explanation: An error occurred while attempting to access the repository.

User response: Contact BMC Support.

BMC202324E

RUV Invalid RPL length length found on the repository.


Explanation: The indicated RPL length is not maximum size, and this is not the last segment of a record. The repository has been corrupted.

User response: Rebuild the repository.

BMC202325E

RUV Invalid data found on the repository.


Explanation: The length field in the record conflicts with the actual length. The repository has been corrupted.

User response: Rebuild the repository.

BMC202326E

RUV Invalid (non RUV) record read from the repository.


Explanation: The record key is invalid. The repository has been corrupted.

User response: Rebuild the repository.

BMC202327I

RUV Repository Access Object - SSID ssid.


Explanation: This message identifies the subsystem ID for the repository access object.

User response: No action is required.

BMC202328E

RUV Public subsystem not available; RS (00000001).


Explanation: The public subsystem was requested but is not available.

User response: Request a specific subsystem or activate a public RUV subsystem.

BMC202329E

RUV ssid subsystem not available; RS (00000002).


Explanation: The specified subsystem is not found on the SSCT chain.

User response: Start the specified subsystem.

BMC202330E

RUV Subsystem ssid is not an RUV subsystem.


Explanation: The RUV REINIT command was not executed on the identified subsystem.

User response: Ensure that the SET SUBSYSTEM command identifies a subsystem on which RUV is active.

BMC202331E

RUV Failure to attach a writer.


Explanation: Accumulation processing was not able to attach a writer for output processing.

User response: Contact BMC Support.

BMC202332E

RUV Failure to attach a reader.


Explanation: During accumulation processing, a reader could not be attached for input processing.

User response: Contact BMC Support.

BMC202333E

RUV Registration of accumulation failed.


Explanation: The registration statement for the accumulation process could not be written to the repository.

User response: Verify that the repository is available and that you have the authority to access it.

BMC202334E

RUV Inactive subsystem ssid.


Explanation: The identified subsystem is not active for RUV.

User response: Ensure that the SET SUBSYSTEM command identifies a subsystem on which RUV is active.

BMC202335E

RUV Concatenated file not allowed for DDName ddname.


Explanation: RUV does not support concatenated files for the input file.

User response: Modify the input ddname so that it does not refer to concatenated files and rerun the job.

BMC202336E

RUV Accumulation Repository error.


Explanation: The registration of the accumulation process failed.

User response: Verify that the repository is available and that you have the authority to access it.

BMC202337E

RUV Invalid SSCT chain.


Explanation: A program check occurred while looking for the subsystem.

User response: If the SSCT chain has been corrupted, you must IPL your system.

BMC202338E

RUV DDName ddname not open.


Explanation: A request cannot be honored because the ddname is not open.

User response: Contact BMC Support.

BMC202339E

RUV No writers are available for the output processing of the accumulation data.


Explanation: All writers failed for the accumulation processing.

User response: Check the accumulation output data sets for errors.

BMC202340E

RUV No IADS item found.


Explanation: A repository search did not find the IADS item.

User response: Contact BMC Support.

BMC202341W

RUV DDName ddname is already open.


Explanation: An open request was made for the specified ddname, but it is already open.

User response: Contact BMC Support.

BMC202342E

RUV Get not allowed, DDName ddname is open for output.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202343E

RUV Put not allowed, DDName ddname is open for input.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202344E

RUV Wrong TCB for close of DDName ddname.


Explanation: A close request was made for the specified ddname, but the task requesting the close is not the correct task.

User response: Contact BMC Support.

BMC202345E

RUV Unexpected concatenation encountered on DDName: ddname.


Explanation: The indicated ddname was found to be concatenated but concatenated data sets are not supported in this context.

User response: Specify a nonconcatenated input data set and rerun the job.

BMC202346E

RUV I/O error on DDName ddname, IEA000IText.


Explanation: The SYNAD exit was entered for a sequential data set and a hardware I/O error was encountered.

User response: For a detailed description of IEA000IText, see the IBM message documentation. For input files, ensure that the actual data agrees with the DCB information for the data set.

BMC202347I

RUV End of data on DDName ddname; value records read.


Explanation: Read processing of value records reached the end of the data in the indicated ddname. This is a normal condition.

User response: No action is required.

BMC202348E

RUV Invalid or missing DDName ddname.


Explanation: RUV received a DEVTYP (SVC 24) return code, indicating that the indicated ddname is not valid.

User response: Correct the JCL and rerun the job.

BMC202349E

RUV Blank or missing DDName.


Explanation: RUV cannot open the file because the ddname is missing or blank.

User response: Contact BMC Support.

BMC202350E

RUV Unable to get value bytes for DDName ddname input buffer.


Explanation: RUV is unable to get a value-byte record buffer for ddname. Abend U104 follows this message.

User response: Contact BMC Support.

BMC202351W

RUV Archive registration skipped.


Explanation: A repository access error occurred that prevented the registration of the archive.

User response: Correct the repository access error and re-archive the archive.

BMC202352E

RUV Repository access error actionID; RC(returnCode); RS(reasonCode).


Explanation: An error occurred while accessing the repository.

User response: Contact BMC Support.

BMC202353E

RUV Item item (format 1) does not contain all required sub-items.


Explanation: Sub-item lengths appear to overlap the end of item item.

User response: Contact BMC Support.

BMC202354E

RUV The entries do not exactly fit into array item item.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202355E

RUV An item was passed a pointer that had a value of zero.


Explanation: A pointer of zero was passed to the item validation routine. Low memory is not a valid item.

User response: Contact BMC Support.

BMC202356E

RUV Item itemCode reserved field not set to zeros (hexValue).


Explanation: RUV encountered an internal error.

User response: Contact BMC Support.

BMC202357E

RUV No IAFD item found.


Explanation: A repository search did not find the IAFD item.

User response: Contact BMC Support.

BMC202358I

RUV Not able to identify file for record.


Explanation: The file to which this record applies is unknown.

User response: The record is accumulated but is not included in reports.

BMC202359W

RUV Archive Record for DSName dataSetName is not active. Data set will NOT be accumulated.


Explanation: The latest repository record for this archive dataSetName is not active. Accumulation continues without the data set.

User response: Change the status of the archive to active and rerun the job.

BMC202360E

RUV STOW failed for DDName ddname member memberName RC(returnCode).


Explanation: RUV was unable to update the PDS directory. The following table describes the return codes:

Return code

Description

12

No more space in directory

16

Permanent I/O error

20

DCB not open

24

Insufficient virtual storage


User response: Perform the appropriate action according to the return code received:

Return code

Action

12

Reallocate the PDS with more directory space.

16

Reallocate the PDS on another volume.

20

Contact BMC Support.

24

Make more storage available.


BMC202361W

RUV Beginning segment was not found in block blockNumber of file DDName ddname.


Explanation: RUV read an invalid record from the indicated block of the indicated ddname. A beginning segment was expected, but the segment descriptor word (SDW) indicates that this is not the first segment of a record.

User response: This is a normal condition when processing a damaged or incomplete archive. Attempt to use another copy of this archive. Refer to active or inactive archive status.

BMC202362W

RUV Ending segment missing in a record in block blockNumber of DDName ddname.


Explanation: RUV read an invalid record from the indicated block of the indicated ddname. A continuation segment was expected, but the segment descriptor word (SDW) indicates that this is the first segment of a record.

User response: This is a normal condition when processing a damaged or incomplete archive. Attempt to use another copy of this archive. Refer to active and inactive archive status.

BMC202363W

RUV Beginning and ending segments missing from block blockNumber of DDName ddname.


Explanation: RUV found an invalid record in the indicated block of the indicated ddname. A middle segment was encountered. The segment descriptor words (SDWs) indicate that the first and last segments are both missing.

User response: This is a normal condition when processing a damaged or incomplete archive. Attempt to use another copy of this archive. Refer to active and inactive archive status.

BMC202364E

RUV Record record in block blockNumber of DDName ddname is less than 8 bytes long.


Explanation: The indicated record is less than eight bytes long. An RUV archive record must be long enough to contain length and count fields. The data set is probably not an RUV archive.

User response: Ensure that the data set being processed is an RUV archive. Contact BMC Support.

BMC202365E

RUV Record record in block blockNumber of DDName ddname is shorter than its llll length.


Explanation: The actual length of the indicated record is less than its llll field. The data set is probably not an RUV archive.

User response: Ensure that the data set being processed is an RUV archive. Contact BMC Support.

BMC202366E

RUV Record record in block blockNumber of DDName ddname is longer than its llll length.


Explanation: The actual length of the indicated record is greater than its llll field. The data set is probably not an RUV archive.

User response: Ensure that the data set being processed is an RUV archive. Contact BMC Support.

BMC202367E

RUV Invalid record sequence in DDName ddname; expected record1; actual record2.


Explanation: RUV encountered an invalid record sequence on ddname. Record number record1 was expected, but record number record2 was read. This is a normal condition when processing a damaged, incomplete, or modified archive. All jobs except the Accumulation job will fail. The Accumulation job will receive return code 8, but the job completes successfully unless RUV encounters other errors.

User response: Check for a BMC202153I message to determine whether the Accumulation job completed successfully. Ensure that the data set being processed is an RUV archive and that it is not being modified.

BMC202368W

RUV Abend intercepted for DDName ddname; abend code abendCode, record number recordNumber.


Explanation: RUV encountered an abend intercepted by a DCBABEND or ESTAE exit. The error occurred in ddname, and recordNumber indicates the number of the record being processed at the time of the error.

User response: No action is necessary for out of space conditions (x37) during batch journaling. Otherwise, correct the problem and rerun the job.

BMC202369E

RUV Record recordNumber intended for DDName ddname with length length is too long.


Explanation: For RECFM=F or FB, the record length (including wrapping) of ddname must equal the LRECL.

User response: Check the RECFM and LRECL of the output data set.

BMC202370E

RUV Record recordNumber intended for DDName ddname with length length is too short.


Explanation: For RECFM=F or FB, the record length (including wrapping) of ddname must equal the LRECL.

User response: Check the RECFM and LRECL of the output data set.

BMC202371E

RUV End of data encountered in item itemCode.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202372E

RUV Sub-item or entry does not exist.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202373E

RUV Invalid format format in item itemCode, A(address).


Explanation: RUV encountered an internal logic error. Valid formats are 0, 1, or 2.

User response: Contact BMC Support.

BMC202374E

RUV No current item found.


Explanation: No item currently exists in the object’s buffer.

User response: Contact BMC Support.

BMC202375E

RUV No current sub-item or array entry found.


Explanation: RUV encountered an internal logic error.

User response: Contact BMC Support.

BMC202376E

RUV Item itemCode is too short; length= length, A(address).


Explanation: All items (and sub-items) must be at least sixteen bytes long.

User response: Contact BMC Support.

BMC202377E

RUV Item itemCode is too long for format format items; length=length, A(address).


Explanation: The indicated item is too long. Format 0 (unstructured) items must be less than 32 KB. All others must be less than 16 MB.

User response: Contact BMC Support.

BMC202378E

RUV Invalid Item itemCode found; hex value= (hexValue), A(address).


Explanation: The indicated item contains invalid eye-catchers. Valid eye-catchers consist of four uppercase characters, from A through Z.

User response: Contact BMC Support.

BMC202379E

RUV Incorrect format format found.


Explanation: The item has an unsupported format for the function requested.

User response: Contact BMC Support.

BMC202380E

RUV Invalid RDW on variable length DDName ddname. Block number blockNumber RDW(rdw).


Explanation: For RECFM=V, VB, VS, or VBS, the first four bytes must be a valid record descriptor word.

User response: Ensure that the actual data agrees with the DCB information from the VTOC, label, or JCL.

BMC202381I

RUV Repository backup for SSID: ssid complete. count records; kcount K bytes.


Explanation: Repository backup for the indicated subsystem is complete, and count records were backed up. The size of the backup is kcount KB.

User response: No action is required.

BMC202382I

RUV Repository restore for SSID: ssid complete. count records; kcount K bytes.


Explanation: Repository restore for the indicated subsystem is complete, and count records were restored. The size of the data restored is kcount KB.

User response: No action is required.

BMC202383I

RUV File: ddname Data set: dataSetName


Explanation: This message displays the file ddname and data set name.

User response: No action is required.

BMC202384I

RUV File: ddname Data set: dataSetName(member)


Explanation: This message displays the file ddname, data set name, and member name.

User response: No action is required.

BMC202385I

RUV File: ddname Data set: dataSetName Error.


Explanation: This message displays the ddname and data set name of the file that is in error.

User response: No action is required.

BMC202386I

RUV File: ddname Data set: **simulated**.


Explanation: This message displays the ddname and data sets that are simulated.

User response: No action is required.

BMC202387E

RUV Rule set (ruleSetName) not found or not activated. ssid


Explanation: The repository control record for this subsystem contained a rule set name that could not be found.

User response: Activate the correct rule set.

BMC202387I

RUV Repository Print for SSID: ssid.


Explanation: This message indicates the subsystem for which the repository is displayed.

User response: No action is required.

BMC202388W

RUV Archive record for DSName dataSetName has no status. Data set will be accumulated.


Explanation: The latest repository record for the indicated data set has no status. Accumulation will continue with the data set.

User response: No action is required.

BMC202389I

RUV recordCount records; bytes K bytes.


Explanation: This message reports the number of records and number of bytes of data that have been processed.

User response: No action is required.

BMC202390E

RUV parameter is missing.


Explanation: The required parameter was not supplied for accumulation processing.

User response: Supply the missing data and rerun the job.

BMC202391E

RUV DSName dataSetName is duplicated in the ARCHIVE_OUT parameter.


Explanation: The specified data set is listed two or more times in the ARCHIVE_OUT parameter.

User response: Remove any duplicate archive specifications and resubmit the job.

BMC202392E

RUV DSName dataSetName base is not found.


Explanation: RUV could not find the dataSetName base.

User response: Correct the data set name, or ensure that the data set name is in the repository

BMC202393E

RUV DSCB function failed RC(returnCode) RS(reasonCode).


Explanation: RUV encountered an error in DSCB functions.

User response: Contact BMC Support.

BMC202394E

RUV Accumulation selection error.


Explanation: RUV encountered an error in accumulation processing.

User response: To determine what action to take, see previous error messages.

BMC202395I

RUV No archives were selected for input.


Explanation: RUV found no active archives for the input.

User response: Verify that valid, active archives exist for the VSAM_FILE input.

BMC202396E

RUV Build Queue failure.


Explanation: RUV encountered an error in creating a queue from reader to writer.

User response: Contact BMC Support.

BMC202397E

RUV Accumulation writer allocation error.


Explanation: RUV encountered a failure in the allocation of a writer.

User response: Contact BMC Support.

BMC202398E

RUV Mount plan failure.


Explanation: RUV encountered a failure in the mount plan.

User response: Contact BMC Support.

BMC202399I

RUV Generated end of batch job for Job: job at gmt GMT.


Explanation: RUV generated the end of the indicated batch job by using the available journals. The message shows the time stamp in GMT.

User response: Ensure that all journals from the batch job were input to the ACCUM job. Correct and rerun the ACCUM job if input journals were missing. If the generated end time is acceptable, no action is required.

Was this page helpful? Yes No Submitting... Thank you

Comments