This page details the storage information collected for each of the supported HP 6000 Storage Systems discovered in your IT infrastructure.

Storage Systems Information

To access the collected information for HP Storage systems:

  1. From the Home page, locate the Quick View section and click the Storage System icon to display the list of the discovered storage systems.

  2. In the Storage System list, double-click the HP P6000 storage system you wish to access.

The table below lists the System Storage Information as discovered and displayed in the BMC Discovery console.

Storage System InformationDescription
NameThe name of the storage system.
TypeThe type name of the storage system.
Client Access TypesThe ways in which a client host can access the storage that this system is providing. This may be SAN, NAS, or SAN and NAS.
VendorThe storage system vendor.
ModelThe model name.
World Wide Node NameThe Unique 64-bit identifier assigned to each Fiber Channel node process.
Total Disk SpaceThe total available space in the storage system in bytes.
Total Subscribed CapacityThe total subscribed capacity in the storage system in bytes.
Total Oversubscribed CapacityTotal space oversubscribed in the storage system.
Managed ByThe software managing the storage system and the host on which it is running, for example, HP Command View EVA CIM Server. This is also a link to the Software Instance page for that software. There may be more than one manager. Refer to the Hosting Server Information section for details.
Storage Processors

A summary table showing the storage processors in the storage system. For each processor the following information is displayed:

  • Processor Identifier
  • Vendor
  • Model
  • Firmware
  • Number of FC Ports

To see the storage processor page, click the corresponding table row.

Storage PoolsDisplays the number of related storage pools. This is also a link to the Storage Pool List page.
Storage VolumesDisplays the number of related storage volumes. This is also a link to the Storage Volume List page.
Disk DrivesDisplays the number of related disk drives. This is also a link to the Disk Drive List page.

Software Instance Information

This section provides information about the software instance of the storage system.

To access the collected information for software instances:

  1. In the Storage System page, locate the Managed By section.

  2. Click the name of the Software Instance.

The table below lists the Software Instance Information as discovered and displayed in the BMC Discovery console.

Software Instance Information

Description

Name

The name of the host system. Typically composed of the Software Instance Name, the Product Version, and the name of the Host.

Type

The type of the software instance that manages the storage system.

Configipedia Page

The name of the associated Configipedia page link.

Instance Count

The number of identical software instances for the hosting server.

Full VersionThe complete version number of the software instance.

Product Version

The version number of the software instance.

Host(s)

The name of the server hosting the software instance.

Manages Storage Systems

The list of the storage systems managed by the software instance.  Refer to the Storage Systems Information section for details.

Maintaining Pattern

The pattern used to create the software instance.

Primary processes

The primary process that identifies this software.

Storage Processors Information

This section provides information about the storage processors managing data transfer for the selected storage system.

To access the collected information for storage processors, click the Storage Processor link available in the Storage System page.

The table below lists the Storage Processors Information as discovered and displayed in the BMC Discovery console.

Storage Processor InformationDescription
Processor IdentifierThe processor identifier.

Vendor

The hardware vendor.

Model

The model name.

Description

The model description.

SerialThe serial number of the processor.

Firmware

The firmware details.
Storage SystemThe name of the storage device. This is also a link to the Storage System page. Refer to the Storage System Information section for details.
Front End FC PortsList of the front-end FC Ports for this processor.  Refer to the Front End FC Port Information section for details.

Front End FC Ports Information

This section provides information about the front-end fiber channel ports transmitting data for the selected storage system.

To access the collected information for Frond End Fibre Channel Ports:

  1. From the Storage Processor page, locate the Front End FC Ports section.
  2. Click the link for the port name you wish to access.

The table below lists the Front End FC Ports Information as discovered and displayed in the BMC Discovery console.

Front End FC Port Information

Description

Port Name

The name of the front end FC port.

WWPN

The World Wide Port Name — Unique serial number of the front end FC port.

Role

The role of the FC port.

Type

The front end FC port type.

State

The front end FC port state.

Speed (Gb/s)

The front end FC port speed (in Gbit/s).

Storage Processor

The storage processor for this port. This is also a link to the Storage Processor page. Refer to the Storage Processors Information section for details.

Exposed Volumes

The volumes exposed through this port. This is also a link to the Storage Volume List page.

Storage Pools Information

This section provides information about the storage pools for the selected storage system.

  1. To access the collected information for storage pools, click the Storage Pools link available in the Storage System page.
  2. In the Storage Pools list, double-click the storage pool you wish to access.

The table below lists the Storage Pools Information as discovered and displayed in the BMC Discovery console.

Storage Pool InformationDescription
Pool IDThe ID of the storage pool.
Type

The type of the storage pool.

NameThe name of the storage pool.
CapacityThe usable capacity of the storage pool.
Consumed CapacityThe space actually consumed in the storage pool in bytes.
Percentage ConsumedThe percentage of space consumed in the storage pool
Available CapacityThe total capacity not consumed in the storage system in bytes.
Subscribed CapacityThe total subscribed capacity in the storage pool.
Percentage SubscribedThe percentage of space subscribed in the storage pool.
Configured Volume CapacityThe sum of all mapped volumes.
Oversubscribed CapacityThe total space oversubscribed in the storage pool.
Oversubscription WarningIndicates whether or not an oversubscription warning is active.
Storage SystemThe name of the storage system for this storage pool. This is also a link to the Storage Systems page. Refer to the Storage Systems Information section for details.
Storage VolumesThe volumes for the storage pool. This is also a link to the Storage Volumes page. Refer to the Storage Volumes Information section for details.

Storage Volumes Information

This section provides information about the storage volumes for the selected storage system.

To access the collected information for storage volumes:

  1. To access the collected information for storage volumes, click the Storage Volumes link available in the Storage System page.

  2. In the Storage Volumes list, double-click the storage volume you wish to access.

The table below lists the Storage Volumes Information as discovered and displayed in the BMC Discovery console.

Storage Volume InformationDescription

Volume ID

The ID of the storage volume.

Name

The name of the storage volume.

NAA IDThe Network Address Authority ID.

Mapped

Indicates whether or not the storage volume is mapped.

Thinly Provisioned

Indicates whether the volume are thinly provisioned or not.

RAID LevelThe RAID level configured for this storage volume.
Visible CapacityThe visible capacity of the storage volume (in GiB).

Consumed From Pool

The capacity consumed from the storage pool related to the storage volume (in GiB).

Consumable Capacity

The consumable capacity in the storage volume (in GiB).

Percentage of Pool Consumed

The percentage of capacity consumed in the storage volume.

Block Size

The block size of the storage volume.

Number of Blocks

The number of blocks of the storage volume.

Consumable Blocks

The number of consumable blocks of the storage volume.

Storage System

The name of the storage system for this storage volume. This is also a link to the Storage Systems page. Refer to the Storage Systems Information section for details.

Storage Pool

Name of the storage pool for this storage volume. This is also a link to the Storage Pools page. Refer to the Storage Pools Information section for details.

Storage Consumers

Name of the storage connections related to the storage volume. This is also a link to the Storage Connection page.

Front End FC Ports

List of the front-end FC ports on the storage volume. This is also a link to the FC Ports page. Refer to the Front End FC Ports Information section for details.

Disk Drives Information

This section provides information about the disk drives for the selected storage system.

To access the collected information for disk drives, click the Disk Drive link available in the Storage System page.

The table below lists the Disk Drives Information as discovered and displayed in the BMC Discovery console.

Disk Drive Information

Description

Name

The name of the disk drive.

TypeThe type of the disk drive.
Current StateThe current state of the disk drive.
SpeedSpeed of the disk drive (in RPM).

Size

The size of the disk drive in bytes.

Vendor

The name of the disk drive vendor.

Model

The model of the disk drive.

Serial NumberThe serial number of the disk drive.

Storage System

Name of the storage system for this disk drive. This is also a link to the Storage Systems page.

Storage Connections Information

A Storage connection represents a connection between a storage client (a host using the storage) and a storage volume. The same connection may be linked to multiple volumes representing the client's visibility of multiple storage volumes. The volumes shown are only those that the client is permitted to access. This section provides information about the Storage Connection for the selected storage volume.

To access the collected information for storage connections, click a Storage Connection link available from a Storage Volume page. 

The table below lists the Storage Connections Information as discovered and displayed in the BMC Discovery console.

Storage Connection Information

Description

Connection Name

The name of the connection.

Connection Type

The type of storage connection.

Connection Value

A unique identifier for the storage consumer using this connection.

  • For WWPN connections this is the fiber channel port name of the host.
  • For iSCSI IQN connections this is iSCSI qualified name (IQN).

Storage Volumes

The name of any storage volumes visible to the host using this connection.

Consumer Fibre Chanel Port

Information on the Fiber channel port on the host using this connection.