Current Year (2023)
New Features and Enhancement
ID | Details | Improved in |
---|---|---|
DRDC1-21650 | Huawei OceanStor and OceanStor Dorado System (REST): We now fully support Huawei OceanStor 5300 V5 via REST APIs. | TKU 2023-Sep-2 |
DRDC1-21434 | Tape Library: Added support for HP TapeLibrary (StoreOnce type) information with the HPE StoreOnce (REST) pattern. | TKU 2023-Sep-2 |
DRDC1-14669 | Huawei OceanStor and OceanStor Dorado System (REST): The pattern now discovers:
| TKU 2023-Sep-2 |
DRDC1-20802 | Ceph Storage Systems: The pattern now handles the discovery of Ceph storage systems directly as a storage device using the Ceph API Access. | TKU 2023-Aug-1 |
DRDC1-18977 | IBM Spectrum Control Storage Systems (REST): Added support for IBM Spectrum Control storage system via IBM Spectrum Control (new pattern). | TKU 2023-Aug-1 |
DRDC1-13916 | NetApp StorageGRID Storage Systems (REST): Added support for NetApp StorageGRID storage systems via the StorageGRID Management API (new pattern). | TKU 2023-Jul-1 |
DRDC1-21204 | Storage pattern populating error message as Vendor & Model on disk Drive node | TKU 2023-Jun-1 |
DRDC1-21184 | HPE StoreOnce Storage Systems: The pattern now supports HPE StoreOnce version 4.x. | TKU 2023-Jun-1 |
DRDC1-19671 | TKU 2023-Jun-1 | |
DRDC1-21162 | Dell EMC PowerMax Storage Systems: Added support for HSL. The pattern now also discovers and reports the NAA ID for storage volumes. | TKU 2023-May-1 |
DRDC1-16176 | TKU 2023-Apr-1 | |
DRDC1-20883 | Storage System's names and models are now discovered and reported for all versions of Cohesity systems. The discovered and reported information for File Systems now include:
| TKU 2023-Apr-1 |
DRDC1-21000 | TKU 2023-Apr-1 | |
DRDC1-20625 | TKU 2023-Apr-1 | |
DRDC1-20818 | TKU 2023-Apr-1 | |
DRDC1-20818 | TKU 2023-Apr-1 | |
DRDC1-12124 | TKU 2023-Mar-1 | |
DRDC1-20418 | TKU 2023-Feb-1 | |
DRDC1-18281/ DRDC1-20092 | TKU 2023-Feb-1 | |
DRDC1-14198 | Cohesity Storage Systems (REST): Added support for Cohesity storage systems (new pattern). | TKU 2023-Jan-1 |
DRDC1-20245 | TKU 2023-Jan-1 | |
DRDC1-20349 | Hitachi Storage Systems:
| TKU 2023-Jan-1 |
Known and corrected issues
ID | Details | Corrected in |
---|---|---|
DRDC1-21508 | Huawei OceanStor and OceanStor Dorado System (REST): FC ports are not discovered when the ID of the port's parent has not the expected format. Fixed. | TKU 2023-Sep-1 |
DRDC1-21559 | Pure Storage Systems: Connection timeout has been increased to allow the discovery of Pure storage systems via the WEB API. | TKU 2023-Aug-1 |
DRDC1-21576 | IBM DS8000 Storage Systems (REST): An ECA Error occurred when scanning a storage system for which no Managed Storage Systems Name is defined. Fixed. | TKU 2023-Aug-1 |
DRDC1-21520 | IBM DS8000 Storage Systems (REST): In some cases, the storage device was not created due to a timeout exception. Fixed. | TKU 2023-Aug-1 |
DRDC1-21493 | HPE StoreOnce Storage Systems: The Storage device was not created due to a timeout exception. Fixed. | TKU 2023-Aug-1 |
DRDC1-21424 | HPE StoreOnce Storage Systems: The pattern fails to report IP address when the REST query on the network does not return a value for interfaces. Fixed. | TKU 2023-Jul-1 |
DRDC1-21323 | NexentaStor Storage Systems (REST): The model information of the storage device is now populated. | TKU 2023-Jun-1 |
DRDC1-21206 | Huawei OceanStor Dorado V3 and V6 Storage Systems (WBEM): Huawei OceanStor Dorado 6000 V6 and Huawei OceanStor Dorado 8000 V6 models are now fully supported. | TKU 2023-Jun-1 |
DRDC1-21076 | TKU 2023-May-1 | |
DRDC1-21207 | TKU 2023-May-1 | |
DRDC1-21129 | TKU 2023-May-1 | |
DRDC1-21151 | TKU 2023-May-1 | |
DRDC1-20439 | TKU 2023-Mar-1 | |
DRDC1-20571 | TKU 2023-Mar-1 | |
DRDC1-20606 | TKU 2023-Mar-1 | |
DRDC1-20439 | IBM SVC/Storwize: All storage chassis and extension chassis are now discovered correctly and associated to the storage system. Disk drives are linked to their related chassis. Disk drives that are not part of a chassis are linked to the storage system node. Note: As the relationship between the storage system and the hardware container node has been changed, it is recommended to delete the older version of the IBM_StorWize_Storage.tpl pattern to remove any previous discovered information. | TKU 2023-Feb-1 |
DRDC1-20212 | IBM SVC/Storwize: The storage system serial number now displays the ID of the system in accordance with the information reported in the IBM Storwize management console. | TKU 2023-Feb-1 |
DRDC1-20491 | DELL EMC PowerStore (REST) Storage Systems: An ECA Error occurs when there is no activity on the storage system. | TKU 2023-Feb-1 |
DRDC1-20492 | Dell EMC PowerMax Storage Systems: Storage systems are not created if the "display_name" is not returned by the REST API. | TKU 2023-Feb-1 |
DRDC1-20532 | QNAP Storage Systems: A CMDB synchronization error occurs when a Hardware Container without a name is discovered. | TKU 2023-Feb-1 |
Previous Years
New Features and Enhancements
To view the TKU release content for the previous years, click Technology Knowledge Updates (TKU) archive.
ID | Details | Improved in |
---|---|---|
DRDC1-20075 | Hitachi NAS Storage Systems: The pattern now creates a storage device for each scanned HNAS node. | TKU 2022-Dec-1 |
DRDC1-20096 | Synology Storage Systems (SNMP): The pattern now discovers all Synology models reported by the MIB. | TKU 2022-Dec-1 |
DRDC1-20066 | TKU 2022-Dec-1 | |
DRDC1-16933 | TKU 2022-Dec-1 | |
DRDC1-19831 | TKU 2022-Nov-1 | |
DRDC1-19928 | TKU 2022-Nov-1 | |
DRDC1-19257 | TKU 2022-Oct-1 | |
DRDC1-19609 | TKU 2022-Oct-1 | |
DRDC1-16931 | TKU 2022-Sep-2 | |
DRDC1-19370 | TKU 2022-Aug-2 | |
DRDC1-18629 | TKU 2022-Aug-2 | |
DRDC1-16216 | TKU 2022-Aug-2 | |
DRDC1-18257 | Dell EMC PowerMax/Symmetrix (REST): Added support for Dell EMC PowerMax/Symmetrix Storage Systems via REST (new pattern). | TKU 2022-Jul-1 |
DRDC1-18260 | HPE Primera Storage Systems: Added support for HPE Primera Storage Systems (new pattern). | TKU 2022-Jul-1 |
DRDC1-18975 | A new Software Instance type supports the discovery of Brocade SANnav Management Portal. | TKU 2022-Jun-1 |
DRDC1-13144 | Ceph Storage Systems: Added support for Ceph Storage Systems (new pattern). | TKU 2022-Jun-1 |
DRDC1-17139 | Netapp Storage systems: The pattern now reports the Storage Pool's RAID status. | TKU 2022-May-1 |
DRDC1-12043 | Tintri Storage Systems: Discovery of Tintri storage systems (new pattern). | TKU 2022-April-1 |
DRDC1-18427 | TKU 2022-April-1 | |
DRDC1-17709 | HPE StoreOnce Storage Systems: Added support for HPE StoreOnce storage systems (new pattern). | TKU 2022-April-1 |
DRDC1-18042 | NetApp Storage Systems: The NetApp CIF Shares are now discovered as separate File System nodes. | TKU 2022-February-1 |
DRDC1-17801 | NetApp Storage Systems: The File System node attribute 'Size' now includes the snapshot size. Also, three new attributes are added to the node File System to represent the Snapshot Size, Snapshot Free and Snapshot Used values. | TKU 2022-February-1 |
DRDC1-17280 | TKU 2022-February-1 | |
DRDC1-17426 | All Storage Patterns: A new relationship between the Storage System/Storage System Group and Host has been implemented to create a direct link in the Visualisation. | TKU 2022-February-1 |
DRDC1-18240 | TKU 2022-February-1 | |
DRDC1-18136 | Dell EMC PowerVault TL2000: Discovery of Dell EMC PowerVault TL2000 storage systems and storage devices. | TKU 2022-February-1 |
DRDC1-18123 | Synology Storage Device Life Cycle Pattern: The following models are now fully supported:
| TKU 2022-February-1 |
DRDC1-17976 | TKU 2022-February-1 | |
DRDC1-15282 | DELL EMC PowerStore (REST): Full discovery of DELL EMC PowerStore storage systems via REST API (new pattern). | TKU 2022-January-1 |
DRDC1-17870 | QNAP Storage Systems: Full discovery of QNAP storage systems via SNMP (new pattern). | TKU 2022-January-1 |
DRDC1-17500 | TKU 2022-January-1 | |
DRDC1-17652 | NetApp SolidFire Storage Systems: The name of storage devices, storage systems and hardware containers now corresponds to the FQDN/DNS name. | TKU 2022-January-1 |
DRDC1-18064 | InfiniBox Storage Systems: The pattern now also reports storage systems' VLAN IP addresses. | TKU 2022-January-1 |
DRDC1-17565 | Sun StorageTek Storage Systems via SSH: The pattern now discovers disk drives, storage pools, storage volumes, storage processors, FC Ports, and IP addresses. | TKU 2022-January-1 |
DRDC1-12193 | IBM XIV Storage Systems: The pattern fails to discover IBM FlashSystem A9000R models. | TKU 2018-Nov-1 |
DRDC1-12197 | Disk Drives Information is missing for Windows host. | TKU 2018-Nov-1 |
DRDC1-12145 | EMC VMAX, VNX (SAN), Symmetrix and CLARiiON: Full discovery and support of Resource Storage Pools. | TKU 2018-Oct-1 |
DRDC1-12129 | HP 3PAR Storage Systems: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU 2018-Oct-1 |
DRDC1-12047 | The EMC Celerra/VNX pattern now fully support EMC eNAS models. | TKU 2018-Oct-1 |
DRDC1-11802 | EMC VMAX, VNX (SAN), Symmetrix and CLARiiON Storage Systems: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU 2018-Oct-1 |
DRDC1-11801 | IBM FlashSystem storage systems: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU 2018-Oct-1 |
DRDC1-10140 | Discover tape drives and frames within IBM TS 3400 Tape Libraries | TKU 2018-Oct-1 |
DRDC1-10139 | Discover tape drives and frames within IBM TS 4500 Tape Libraries | TKU 2018-Oct-1 |
DRDC1-10138 | Discover tape drives and frames within IBM TS 3500 Tape Libraries | TKU 2018-Oct-1 |
DRDC1-11970 | Host-Side Linking (ESX) : Link between virtual Disk Drives on the hosted virtual hosts to the actual physical device(s) providing storage capacity (storage volumes, physical disk drives) is not created. | TKU 2018-Oct-1 |
DRDC1-12020 | EMC Data Domain Storage Systems: The pattern has been updated to properly discover EMC Data Domain Storage Systems based on the model name and its OS version. | TKU 2018-Sep-1 |
DRDC1-11873 | Hitachi Storage Systems: An unexpected output is returned by the HDS Embedded SMI-S that leads to a parsing problem when discovering the Storage Volume NAA attribute and prevents the HSL from performing properly. A new parsing method has been implemented to fix these issues | TKU 2018-Sep-1 |
DRDC1-11965 | HP 3PAR Storage Systems: The Total Capacity, Available Capacity and Allocated Capacity attributes are not reported accurately for the Storage System node. | TKU 2018-Sep-1 |
DRDC1-11664 | EMC Storage Systems: EMC VMAX 300 models are not properly discovered when linked to other remote VMAX array. Fixed in the code. Note: TKU for Storage and TKU must be installed to benefit from this fix. | TKU 2018-Sep-1 |
DRDC1-7505 | EMC RecoverPoint: The pattern only uses the REST credentials to discover storage systems. | TKU 2018-Aug-1 |
DRDC1-11138 | Hitachi G-Series: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU July-2018-1 |
DRDC1-10027 | EMC Data Domain: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU July-2018-1 |
IBM SVC/Storwize: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU July-2018-1 | |
DRDC1-8877 | Hitachi non G-Series: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU July-2018-1 |
DRDC1-8877 | HP P9000: A new node, Hardware Container, now regroups the metrics for all the discovered hardware components in a storage system. | TKU July-2018-1 |
DRDC1-11735 | AIX host side linking pattern updated in order to not skip AIX LPAR system where wparid set to 0 | TKU July-2018-1 |
DRDC1-11398 | Host-Side Linking: Ignore ramdisks during disk drive discovery | TKU July-2018-1 |
DRDC1-11273 | BMC Discovery now discovers the EMC Elastic Cloud Storage Portal. | TKU June-2018-1 |
DRDC1-11418 | SAN Brocade: The version of Brocade Network Advisor (BNA) is now detected and reported for both Windows and UNIX systems. | TKU June-2018-1 |
DRDC1-11351 | Nimble Storage Systems: The pattern now only uses the REST credentials to discover storage systems. | TKU May-2018-1 |
DRDC1-7351 | Brocade SANSwitch_FCPorts pattern: The pattern has been updated to discover and report the relationship between the Brocade SAN switch port and the connected storage systems/hosts (Available on BMC Discovery v11.2 an higher). If the Brocade SAN Switch is running in Virtual Fabric (VF) mode, please refer to Discovering Brocade SAN Switches Running in Virtual Fabric Mode. | TKU May-2018-1 |
DRDC1-10707 | EMC DataDomain 9300 device added | TKU May-2018-1 |
DRDC1-10971 | Linux HSL - support added for EMC PowerPath devices | TKU Apr-2018-1 |
DRDC1-9167 | Full support of OceanStor 9000 Storage Systems. | TKU Apr-2018-1 |
DRDC1-4826 | Full support of Nutanix Storage Systems. | TKU Mar-2018-1 |
DRDC1-10321 | Full support of NetApp 9 via Data ONTAP REST API. | TKU Mar-2018-1 |
DRDC1-4690 | Full support of Nimble Storage Systems. | TKU Feb-2018-2 |
DRDC1-9387/DRDC1-9380 | EMC CLARiiON, Symmetrix and VMAX Storage Systems: Information about data encryption for storage systems, volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Feb-2018-1 |
DRDC1-10452 | Full support of Huawei OceanStor V5 | TKU Feb-2018-1 |
DRDC1-10596 | The VPLEX pattern has been optimized to offer better performances. The JSON normalization is now executed only once just after getting the result from the device. | TKU Feb-2018-1 |
DRDC1-10385 | Hitachi Content Platforms systems are now fully supported. | TKU Jan-2018-1 |
DRDC1-10461 | The EMC VPLEX pattern now creates the cluster storage system key using the cluster serial number to avoid duplicated clusters (serial_number_cluster.name). | TKU Jan-2018-1 |
DRDC1-8760/DRDC1-10567 | IBM XIV Storage Systems: The pattern now supports IBM FlashSystem A9000 systems. | TKU Jan-2018-1 |
DRDC1-9385 | EMC XtremIO Storage Systems: Information about data encryption for volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Jan-2018-1 |
DRDC1-10542 | HP 2000 Storage Systems: Information about data encryption for disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Jan-2018-1 |
DRDC1-9384 | HP 3PAR Storage Systems: Information about data encryption for volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Jan-2018-1 |
DRDC1-9386 | Pure Storage Storage Systems: Information about data encryption for volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Jan-2018-1 |
DRDC1-9383 | Hitachi G-Series Storage Systems: Information about data encryption for volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU Jan-2018-1 |
DRDC1-10083 | HSL local disk drives are not created on Windows Desktop | TKU Jan-2018-1 |
DRDC1-8216 | ESX_Storage pattern updated in order to create StorageUse links from VM Hosts to the physycal StorageVolumes/DiskDrives. | TKU-DEC-2017-1 |
DRDC1-10023 | EMC ViPR SRM is now discovered. | TKU-OCT-2017-1 |
DRDC1-6355 | Cisco SANSwitch_FCPorts pattern: The pattern has been updated to discover and report the relationship between the switch port and the connected storage systems/hosts (Available on BMC Discovery v11.2 an higher). | TKU-OCT-2017-1 |
DRDC1-9755 | Huawei OceanStor and Dorado V3 Storage Systems: Information about data encryption for volumes and disk drives has been added to the storage pattern. The Encryption attribute is set to Yes when encryption is enabled or to No when disabled. | TKU-OCT-2017-1 |
DRDC1-9933 | Fujitsu ETERNUS Storage Systems: Added enclosure serial numbers. | TKU-OCT-2017-1 |
DRDC1-9959 | IBM DS6000 and DS8000 Storage Systems: Added disk enclosure serial number for IBM DS8000 models. | TKU-OCT-2017-1 |
DRDC1-9951 | Pure Storage FlashArray Storage Systems: Added enclosure serial number for disk drive nodes | TKU-OCT-2017-1 |
DRDC1-9871 | ESX_Storage pattern updated in order to avoid possible ESA-errors | TKU-SEP-2017-1 |
DRDC1-9759 | The IBM SVC/Storwize Storage System pattern now reports on the storage volume preferred canister. | TKU-SEP-2017-1 |
DRDC1-9508 | Information about data encryption for VNXe storage systems, storage volumes and disk drives has been added to storage patterns. The Encryption attribute is set to True when encryption is enabled or to False when disabled. | TKU-SEP-2017-1 |
DRDC1-9441 | The IBM SVC/Storwize Storage System pattern now reports on the storage processor serial number. | TKU-SEP-2017-1 |
DRDC1-9392 | Need Storage System node created for supported storage tape devices | TKU-SEP-2017-1 |
DRDC1-8553 | New Storage Device integration: IBM TS 4500 Tape Library | TKU-SEP-2017-1 |
DRDC1-9448 | New Storage Device integration: IBM TS 3400 Tape Library | TKU-AUG-2017-1 |
DRDC1-8969 | New Storage Device integration: HP ESL G3 Tape Library | TKU-AUG-2017-1 |
DRDC1-8408 | Added disk location information on NetApp storage systems. | TKU-AUG-2017-1 |
DRDC1-8399 | Added disk location information on Dell Compellent storage systems. | TKU-AUG-2017-1 |
DRDC1-8882 | New Storage Device integration: Oracle StorageTec Tape Libraries | TKU-JUL-2017-1 |
DRDC1-9136 | New Storage Device integration: Quantum iScaler i500 Tape Library | TKU-JUL-2017-1 |
DRDC1-9292 | The EMC Data Domain pattern now fully support the discovery of EMC Data Domain DD6800 and EMC Data Domain Jupiter. | TKU-JUL-2017-1 |
DRDC1-9033 | The EMC Isilon Storage pattern now supports EMC Isilon Storage Systems Version 8.x. | TKU-JUL-2017-1 |
DRDC1-8407 | Added disk location information for EMC Isilon storage systems. | TKU-JUL-2017-1 |
DRDC1-8406 | Added disk location information on HP P9000 storage systems. | TKU-JUL-2017-1 |
DRDC1-8394 | Added disk location information for Hitachi Disk Arrays storage systems. | TKU-JUL-2017-1 |
DRDC1-8390 | Added disk location information for Dell EqualLogic storage systems. | TKU-JUL-2017-1 |
DRDC1-9080 | New Storage Device integration: Quantum iScaler i6000 Tape Library | TKU-JUN-2017-1 |
DRDC1-8561 | New Storage Device integration: Quantum iScaler i2000 Tape Library | TKU-JUN-2017-1 |
DRDC1-9050 | New Storage Device integration: IBM TS 3500 Tape Library | TKU-JUN-2017-1 |
DRDC1-9088 | Remote monitoring for EMC Symmetrix systems is now disabled by default. | TKU-JUN-2017-1 |
DRDC1-8507 | The HP 3PAR Storage pattern now discovers and reports on the amount of free capacity for disk drives (NearLine Disk Drive type only). | TKU-JUN-2017-1 |
DRDC1-8404 | Added disk location information to EMC Data Domain storage systems. | TKU-JUN-2017-1 |
DRDC1-8402 | Added disk location information to Pure Storage storage systems. | TKU-JUN-2017-1 |
DRDC1-8398 | Added disk location information to IBM Flash Systems. | TKU-JUN-2017-1 |
DRDC1-8395 | Added disk location information to Hitachi G-series storage systems. | TKU-JUN-2017-1 |
DRDC1-8393 | Added disk location information to Fujitsu Eternus storage systems. | TKU-JUN-2017-1 |
DRDC1-8387 | Added disk location information to IBM XiV storage systems. | TKU-JUN-2017-1 |
DRDC1-6300 | New Storage Device integration: HP StoreEver MSL4048 Tape Library | TKU-2017-May-1 |
DRDC1-8622 | New Storage Device integration: HP StoreEver MSL6480 Tape Library | TKU-2017-May-1 |
DRDC1-8301 | Add additional approach of getting NAA IDs of EMC Symmetrix and NetApp storage volumes for AIX Host Side Linking | TKU-2017-May-1 |
DRDC1-8389 | Add disk location information to HP P2000 storage systems. | TKU-2017-May-1 |
DRDC1-8388 | Add disk location information to IBM SVC-Storwize storage systems. | TKU-2017-May-1 |
DRDC1-8409 | Add disk location information to EMC Unity storage systems. | TKU-2017-May-1 |
DRDC1-4516 | Documentation for Host Side Linking for Solaris is now available. | TKU-2017-May-1 |
DRDC1-4532 | Documentation for Host Side Linking for AIX is now available. | TKU-2017-May-1 |
DRDC1-5200 | Documentation for Host Side Linking for ESX is now available. | TKU-2017-May-1 |
DRDC1-4789 | Documentation for Host Side Linking for KVM is now available. | TKU-2017-May-1 |
DRDC1-8400 | EMC XtremIO Storage Systems: Added support for disk drive location. | TKU-2017-Apr-2 |
DRDC1-8326 | IBM SVC Storage Systems: Added support for virtual disk drive (MDisks). | TKU-2017-Apr-1 |
DRDC1-8537 | The DELL Compellent Storage Systems pattern now supports the latest version of Dell compellent (Dell Compellent SC040). | TKU-2017-Apr-1 |
DRDC1-8386 | HP 3PAR Storage Systems: Added support for disk drive location. | TKU-2017-Apr-1 |
DRDC1-8392 | EMC CLARiiON/Symmetrix Storage Systems: Added support for disk drive location. | TKU-2017-Apr-1 |
DRDC1-8397 | Huawei OceanStor Storage Systems: Added support for disk drive location. | TKU-2017-Apr-1 |
DRDC1-8401 | EMC VNXe 3200 Storage Systems: Added support for disk drive location. | TKU-2017-Apr-1 |
DRDC1-8416 | EMC VPLEX: The discovery process has been improved. | TKU-2017-Apr-1 |
DRDC1-8546 | The Hitachi Network Attached Storage (HNAS) pattern has been updated to avoid duplicate serial number values in CMDB for virtual servers. | TKU-2017-Apr-1 |
DRDC1-8547 | The Hitachi Network Attached Storage (HNAS) pattern has been improved to fully support virtual storage systems in CMDB. | TKU-2017-Apr-1 |
DRDC1-7868 | Linux Host-Side Linking: The pattern overall performance and capability have been improved: support for multipath partitions, LVM detection, etc. | TKU-2017-Apr-1 |
DRDC1-8416 | EMC VPLEX: The discovery process has been improved. | TKU-2017-1-Mar |
DRDC1-7990 | EMC Unity Storage Systems are now fully supported. | TKU-2017-Feb-1 |
DRDC1-7482 | The HP P2000 pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2017-Jan-1 |
DRDC1-7481 | The Pure Storage pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2017-Jan-1 |
DRDC1-7479 | The EMC VNXe pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2017-Jan-1 |
DRDC1-6551 | The EMC VPLEX pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2017-Jan-1 |
DRDC1-7748 | Windows HSL: Added support for Storage Volumes having NAA ID in IEEE Registered format (i.e. starting from 5h, 8 bytes long). | TKU-2017-Jan-1 |
DRDC1-7698 | AIX HSL: Added support for Storage Volumes having NAA ID in IEEE Registered format (i.e. starting from 5h, 8 bytes long). | TKU-2017-Jan-1 |
DRDC1-7305 | Windows Storage Pattern: The Size attribute of DiskDrives has been changed from string to integer. | TKU-2017-Jan-1 |
DRDC1-4825 | EMC XtremIO Storage Systems (WBEM) are now fully supported. | TKU-2016-Dec-1 |
DRDC1-7477 | The IBM XiV pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Dec-1 |
DRDC1-7478 | The IBM DS6000/8000 pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Dec-1 |
DRDC1-7480 | The HP 3PAR pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Dec-1 |
DRDC1-6874 | The EMC Isilon pattern now discovers the following parameters for File Systems:
| TKU-2016-Nov-1 |
DRDC1-7149/DRDC1-7156 | The EMC CLARiiON/Symmetrix pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Nov-1 |
DRDC1-7203 | The Hitachi Non-G-Series pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Nov-1 |
DRDC1-7204 | The Hitachi G-Series pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Nov-1 |
DRDC1-7205 | The IBM SVC/Storwise pattern has been optimized to improve the discovery of volumes in large environments. | TKU-2016-Nov-1 |
DRDC1-7228 | The Pool ID is now discovered and reported for all EMC Isilon Storage Pools. | TKU-2016-Nov-1 |
DRDC1-6932 | The EMC Celerra Pattern now discovers disk drives, storage pools and storage volumes. | TKU-2016-Oct-1 |
DRDC1-6809 | The discovery of Hitachi G and non-G volumes has been optimized. | TKU-2016-Sep-1 |
DRDC1-5781 | EMC VNXe 3200 Series Storage Systems are now fully supported. | TKU-2016-Jul-1 |
DRDC1-642 | Relationship between Storage System and Storage Volume Mirror are now fully supported for IBM SVC/Storwize storage systems. | TKU-2016-Jul-1 |
DRDC1-5895 | The Host Side Linking pattern for AIX (AIX Storage) reworked in order to improve performance and scalability | TKU-2016-Jun-1 |
DRDC1-6362 | The Host Side Linking pattern for Windows (Windows Storage) updated in order to support Pure Storage FlashArray storage systems | TKU-2016-Jun-1 |
DRDC1-3202 | Pure Storage FlashArray storage systems can now be discovered. | TKU-2016-Jun-1 |
DRDC1-4006 | IBM SVC/Storwize – The Storage Volume mirroring is now fully supported. | TKU-2016-Jun-1 |
DRDC1-6013 | Huawei OceanStor Storage SAN Storage Systems are now fully supported. | TKU-2016-May-1 |
DRDC1-6132 | Huawei OceanStor Storage NAS Storage Systems are now fully supported. | TKU-2016-May-1 |
DRDC1-5390 | The EMC Storage Systems pattern now discovers EMC VPLEX mirrored volumes. The information about mirrored volumes is currently not directly visible in the UI, however you can run queries to retrieve it as follows:
The next version of BMC Discovery (currently scheduled for Q3) will provide an interface to show mirrored volumes information natively. | TKU-2016-May-1 |
N/A | Documentation for Linux and Windows Host Side Linking is now available | TKU-2016-May-1 |
DRDC1-5840 | ESX Storage pattern enhancement. Add new links from VM to backing storage device. | TKU-2016-Mar-1 |
DRDC1-5924 | Mac OS X Storage support (for local disks only) new pattern. | TKU-2016-Mar-1 |
DRDC1-5601/ | BMC Discovery scan failure on EMC Isilon device: Isilon storage pattern need to handle command privileges correctly. To execute commands, the SSH user account must have root privileges or at least sudo privileges on Isilon systems to execute commands. (Note: Documentation has been updated). | TKU-2016-Feb-1 |
DRDC1-5571 | BMC Discovery scan failure on EMC Isilon device. Fixed in the code. | TKU-2016-Feb-1 |
DRDC-4830 | IBM FlashSystem storage systems are now fully supported. | TKU-2016-Feb-1 |
DRDC1-3341 | Hitachi HNAS storage systems are now fully supported. | TKU-2016-Feb-1 |
DRDC1-4593 | Hitachi VSP G Series storage systems are now fully supported. | TKU-2016-Feb-1 |
DRDC1-3200 | EMC Data Domain storage systems are now fully supported. | TKU-2016-Feb-1 |
QM001890921 | The storage systems patterns now support the Host Side Linking for VMs running on ESX servers. | TKU 2016-Jan-1 |
DRDC1-5000 | The locateCommands function declared in storage TPLs is now reported in: //addm/tkn_main/tku_patterns/CORE/SupportingFiles/Common_Functions.tplpre and performed in any TPL when required. | TKU 2016-Jan-1 |
DRDC1-3308 | Dell EqualLogic PS Series storage systems can now be discovered. | TKU 2015-Dec-1 |
DRDC1-4516 | The storage systems patterns now support the Host Side Linking for Solaris. | TKU 2015-Dec-1 |
DRDC1-4999 (internal) | Internal Isilon storage pattern code enhancement. (no functional change). | TKU 2015-Nov-1 |
DRDC1-3813 / QM001880083 | EMC Isilon is now fully supported. | TKU 2015-Oct-1 |
TKU- 4367 | The storage systems patterns now report on Volume Configured Capacity for Storage Pools. | TKU 2015-Oct-1 |
DRDC1-4367 | EMC Symmetrix V-Max now supports SMI-S Provider v.8. | TKU 2015-Oct-1 |
QM001862445 / TKU-2945 | Oracle ZFS NAS storage systems can now be discovered. | TKU 2015-Sep-1 |
QM001866441 / QM001874358 / TKU-3994 | Fujitsu Eternus storage systems can now be discovered. | TKU 2015-Sep-1 |
TKU-4299 | The storage systems patterns now support Windows 2012. | TKU 2015-Aug-1 |
TKU-4118 | The storage systems patterns now support the Host Side Linking for MS Hyper-V. | TKU 2015-Aug-1 |
Known and corrected issues
ID | Details | Corrected in |
---|---|---|
DRDC1-20145 | TKU 2022-Dec-1 | |
DRDC1-19478 | Tintri Storage Systems: The Containment relationship between Ethernet port and processor has been replaced with the Device Interface relationship. | TKU 2022-Sep-1 |
DRDC1-19476 | InfiniBox Storage Systems: The Containment Relationship between Ethernet ports and processor nodes has been removed. | TKU 2022-Sep-1 |
DRDC1-19509 | EMC Isilon Storage Systems: The Smart Connect IP Address and the File System quota size were not discovered and calculated correctly on Isilon systems running OneFS version 8.3 and above. Fixed in the code. | TKU 2022-Sep-1 |
DRDC1-19338 | Dell EMC PowerStore Storage Systems: The REST API calls between Hosts and Host Groups have been optimized to avoid multiple unnecessary requests that could lead to stopping the discovery process. | TKU 2022-Aug-1 |
DRDC1-19413 | TKU 2022-Aug-1 | |
DRDC1-18399 | Dell EMC Elastic Cloud Storage (ESC) Storage Systems: The storage pools and the storage system groups are now correctly synchronized in the CMDB. | TKU 2022-Aug-1 |
DRDC1-19184 | Netapp Storage systems: Relationship missing between the remote and exported File System for the File Systems mounted with the Storage System's name. Fixed in the code. | TKU 2022-Jul-1 |
DRDC1-19159 | All Storage Patterns: The CI BMC_ResourcePool now has correct impact in the CMDB. | TKU 2022-Jul-1 |
DRDC1-18342 | All Storage Patterns: The CMDB now correctly synchronizes Network Interface nodes attached to Storage Processors. | TKU 2022-Jul-1 |
DRDC1-18671 | Tintri Storage Systems: Update of the file system linking between Exported and Remote File Systems for File Systems created from a Storage Pool. | TKU 2022-Jul-1 |
DRDC1-18822 | EMC XtremIO Storage Systems: Missing CMDB relationships between Storage System Groups to related hosts. Fixed in the code. | TKU 2022-Jun-1 |
DRDC1-18726 | Netapp Storage systems: The pattern reported duplicate Network Interface nodes with duplicate MAC addresses. Fixed in the code. | TKU 2022-May-1 |
DRDC1-18624 | EMC XtremIO Storage Systems: Storage systems were not discovered in multi-cluster environments. Fixed in the code. | TKU 2022-May-1 |
DRDC1-18769 | HPE StoreOnce Storage Systems: An ECA Error occurred when a REST API request returned ports with no numeric format. Fixed in the code. | TKU 2022-May-1 |
DRDC1-18549 | IBM SVC Storage Systems: Unavailable volumes are not deleted from discovery. Fixed in the code. | TKU 2022-April-1 |
DRDC1-18428 | QNAP Storage Systems: TS-412U devices not created. Fixed in the code. | TKU 2022-April-1 |
DRDC1-18458 | NetApp SolidFire Storage Systems: The pattern did not try resolving other credentials when first credentials resolution fails. Fixed in the code. | TKU 2022-March-1 |
DRDC1-18454 | Dell EMC PowerStore Storage Systems: Some devices were erroneously identified as Dell EMC PowerStore devices. Fixed in the code. | TKU 2022-March-1 |
DRDC1-18097 | NetApp SolidFire Storage Systems: The pattern could erroneously discover and report non-SolidFire devices. Fixed in the code. | TKU 2022-January-1 |
DRDC1-17756 | InfiniBox Storage Systems: Fixed an ECA error that occurred when the ethernet port's result is empty. | TKU 2022-January-1 |
DRDC1-16244 | EMC Symmetrix/Clariion Storage Systems: The pattern now display the DNS name of the SMIS for the storage device name. | TKU 2021-March-1 |
DRDC1-16190 | NetApp (REST API) Storage Systems: The Junction Path is added to the file system alias name. | TKU 2021-March-1 |
DRDC1-16106 | Fixed broken links to Configipedia Storage pattern pages. | TKU 2021-March-1 |
DRDC1-15419 | HP P4000 Storage Systems: Documentation is now available for HP P4000 storage systems. | TKU 2021-March-1 |
DRDC1-16456 | VMware.VMStorage: ECA Error for ESXi host after HSL for VMs switched on | TKU 2021-March-1 |
DRDC1-16312 | EMC Celerra/VNX (NAS) and eNAS Storage Systems: An ECA Error occurred when a WBEM request returned an empty list. Fixed in the code. | TKU 2021-February-1 |
DRDC1-16298 | EMC Unity Storage Systems: Some storage systems were not discovered when WBEM requests returned blank results. Fixed in the code. | TKU 2021-February-1 |
DRDC1-16163 | NetApp Storage System (REST): The OS Version attribute for Storage Devices is now correctly reported. | TKU 2021-February-1 |
DRDC1-15951 | Hitachi VSP G-Series Storage Systems: Volumes were not mapped when the pattern failed to discover disk drives. | TKU 2021-February-1 |
DRDC1-15673 | Pure Storage FlashArray Storage Systems: The Type attribute is now correctly reported for storage devices on BMC Discovery v11.3. | TKU 2021-February-1 |
DRDC1-16208 | Hitachi Storage Systems: Hitachi HUS Storage Devices are now correctly discovered and displayed. | TKU 2021-January-1 |
DRDC1-16172 | All patters using Common_Network_Functions.tplpre: The Scope value was not set properly for the Subnet nodes. As a result, the Subnet nodes were related between multiple scope environment. | TKU 2021-January-1 |
N/A | IBM DS6000 and DS8000 Storage Systems: IBM Hardware Management Console (HMC) v9 no longer supports the CIM Agent/WBEM protocol, which is used by our pattern to access the IBM DS8x systems. | TKU 2021-January-1 |
DRDC1-8231 | HP 3PAR disk drive types are now accuratly reported. | TKU-2017-1-Mar |
DRDC1-7618 | Disk Drive location information is now reported for IBM DS 6000/8000 storage systems. | TKU-2017-Feb-1 |
DRDC1-6554 | HSL on Solaris: Links between File Systems on MetaMirrors (Sun Volume Manager, SVM) and their underlying disks are now properly reported. | TKU-2017-Feb-1 |
DRDC1-8089 | EMC VPLEX: The following metrics are no longer reported:
| TKU-2017-Feb-1 |
DRDC1-7134 | Hitachi HUS LUNs HSL on Windows OS: Links between servers and Hitachi HUS LUNs are now properly modeled and reported. | TKU-2017-Feb-1 |
DRDC1-8227 | The Storage System Type for NetApp Storage Cluster v8.3.2p3 model is now properly discovered and reported. | TKU-2017-Feb-1 |
DRDC1-6874 | The names of the EMC Isilon File Systems are now properly reported. | TKU-2016-Nov-1 |
DRDC1- 7404 | CA Error now handled when no data is returned for the File System capacities. Also, the tree path has been updated for the Hitachi HNAS pattern, now the pattern is located under: Storage Systems/Hitachi/HNAS. | TKU-2016-Nov-1 |
DRDC1-6702 | Some NetApp Clustered Devices were reporting Virtual Serial numbers for Physical devices. Fixed in the code. | TKU-2016-Oct-1 |
DRDC1-6388 | The Size of NetApp Qtrees with no quota is now reported as the volume size. | TKU-2016-Sep-1 |
DRDC1-6457 | The Type of NetApp disk drive is now properly discovered and reported. | TKU-2016-Sep-1 |
DRDC1-6389 | The Type of NetApp Qtree file systems is now properly discovered and reported. Known Limitation: NetApp root filesystems Type cannot currently be discovered via SNMP. | TKU-2016-Sep-1 |
DRDC1-6810 | The NAA of Hitachi Storage Volumes is now correctly reported for USP-VM storage systems. | TKU-2016-Sep-1 |
DRDC1-6774 | The Storage System Type for Hitachi USP-VM models is now properly discovered and reported. | TKU-2016-Sep-1 |
DRDC1-6777 | EMC VPLEX cluster models are now properly discovered and reported. | TKU-2016-Sep-1 |
DRDC1-4789 | The Host Side Linking pattern for Red Had KVM is now fully functional. | TKU-2016-Aug-1 |
DRDC1-6204 | The ECA error in Windows Storage pattern cased by DeviceIdentifier Page format has been fixed. | TKU-2016-Aug-1 |
DRDC1-644 | Wrong serial number for VPLEX cluster. Fixed in the code. | TKU-2016-Jul-1 |
DRDC1-654 | VPLEX box detection and identification has been improved. | TKU-2016-Jul-1 |
DRDC1-653 | The EMC Esilon TPL now properly discovers the number of disks. | TKU-2016-Jul-1 |
DRDC1-4699 | The Host Side Linking pattern for Windows (Windows Storage) updated in order to avoid errors when DeviceID wasn't obtained from wmi request | TKU-2016-Jun-1 |
DRDC1-6387 | VPLEX version found in REST API does not match the version reported by vplexcli. Fixed in the code. | TKU-2016-Jun-1 |
DRDC1-6326 | Fujitsu Eternus Storage System had a non-unique Storage Pool instanceID. Storage Pools instances now include their unique storage system serial numbers | TKU-2016-Jun-1 |
DRDC1-6325 | Dell EqualLogic Storage System had a non-unique Storage Pool instanceID. Storage Pools instances now include their unique storage system keys. | TKU-2016-Jun-1 |
DRDC1-6324 | Dell Compellent Storage System had a non-unique Storage Pool instanceID. Storage Pools instances now include their unique storage system serial numbers. | TKU-2016-Jun-1 |
DRDC1-6301 | Hitachi G1000 scan failure on "NoAccess (DeviceInfo from heuristics)" when returning more than 2 chassis. Fixed in the code. | TKU-2016-Jun-1 |
DRDC1-6287 | HP 3PAR Storage System had a non-unique Storage Pool instanceID. Storage Pools instances now include their unique storage system keys. | TKU-2016-Jun-1 |
DRDC1-6072 | The Hitachi Storage Systems pattern. The issue related to the empty Storage Pool Name has been fixed. | TKU-2016-May-1 |
DRDC1-6050 | The ECA error generated by the EMC Isilon pattern has been fixed. | TKU-2016-May-1 |
DRDC1-6220 | The version of the SMI-S for EMC ECOM (CLARiiON and Symmetrix) is now properly discovered. | TKU-2016-May-1 |
DRDC1-5940 | The Host Side Linking pattern for Linux (Linux Storage) have been improved to to support local 'logical' disks behind array controllers. | TKU-2016-Apr-1 |
DRDC1-5791 | Hitachi Storage Pattern: The computing of the subscribed capacity for Disk Groups has been improved. | TKU-2016-Apr-1 |
DRDC1-5856 | AIX Storage Pattern ECA Error (caused by LocateCommand function) | TKU-2016-Mar-1 |
DRDC1-5834 | Some Brocade Fibre Channel devices show wrong speed on ports | TKU-2016-Mar-1 |
DRDC1-5596 | CTI info for SAN Switches are not correct | TKU-2016-Mar-1 |
DRDC-5402 | Problem: ECA error in the Solaris_Storage pattern. Resolution: Fixed in the code. | TKU 2016-Jan-1 |
QM001889855 / ISS04562350, | Problem: ECA error in the Windows_Storage pattern. Resolution: Fixed in the code. | TKU-2015-Nov-2 |
QM001888582 / | Problem: ECA error in the Linux_Storage pattern. Resolution: Fixed in the code. | TKU-2015-Nov-2 |
DRDC1-5174 | Problem: IBM Storwize pattern keryError. Resolution: Fixed in the code. | TKU-2015-Nov-2 |
ISS04520759 / QM001886743 / TKU-4814 | Problem: ECA error in ESX storage Linkage. Resolution: Fixed in the code. | TKU 2015-Sep-1 |
ISS04521768 / QM001886335 / TKU 4747 | Problem: When discovering volumes without multipath, we get an ECA Error message. Resolution. Fixed in the code. | TKU 2015-Sep-1 |
ISS04521777 / QM001886864 / TKU 4815 | Problem: When trying to extract the disk size from some volumes, we get an ECA Error message. Resolution: Fixed in the code. | TKU 2015-Sep-1 |
ISS04524346 / QM001887125 / TKU 4836 | Problem: When scanning IBM DS8000 storage device we get an ECA error message. Resolution: Fixed in the code. | TKU 2015-Sep-1 |
QM001882086 / TKU 4375 | Problem: Netapp os_type is wrong Resolution: Fixed in the code. Now correct OS is displayed for Netapp. | TKU 2015-Jul-1 |
TKU 4254 | Problem: Wrong Disk Array Size when multiple chassis are interconnected. Resolution: Fixed. The pattern now takes into account the Primordial Imported Storage Pool. | TKU 2015-Jun-1 |
TKU 2432 | Problem: WWNN for VNX35 is not displayed. Resolution: WWNN is now displayed for VNX and Clariion System. | TKU 2015-Apr-1 |
TKU 3524 | Problem: The current status of HP2000 disk drives is not displayed. Resolution: Fixed. The current status of HP2000 disk drives is now displayed. | TKU 2015-Apr-1 |
TKU 3525 | Problem: The current status of HP6000 disk drives is not displayed. Resolution: Fixed. The current status of HP6000 disk drives is now displayed. | TKU 2015-Apr-1 |
TKU 3523 | Problem: The current status of EMC disk drives is not displayed. Resolution: Fixed. The current status of EMC disk drives is now displayed. | TKU 2015-Apr-1 |
TKU 3527 | Problem: The current status of IBM SVC disk drives is not displayed. Resolution: Fixed. The current status of IBM SVC disk drives is now displayed. | TKU 2015-Apr-1 |
TKU 3526 | Problem: The current status of IBM DS disk drives is not displayed. Resolution: Fixed. The current status of IBM DS disk drives is now displayed. | TKU 2015-Apr-1 |
TKU 3521 | Problem: The current status of Hitachi disk drives is not displayed. Resolution: Fixed. The current status of Hitachi disk drives is now displayed. | TKU 2015-Apr-1 |
QM001876012 | Problem: Some parameters used to properly identify storage pools and volume types no longer exist in the latest version of the SMI-S provider embedded with EMC Solution Enabler v8.0.1. Resolution: Fixed in the code. The product has been modified to comply with the SMI-S provider for EMC Solution Enabler v8.0.1. | TKU 2015-Mar-1 |
TKU-2435 | Problem: EMC primordial storage pools should be hidden. Resolution: EMC primordial storage pools are no longer displayed. | TKU 2015-Mar-1 |
TKU-2436 | Problem: HP P2000 primordial storage pools should be hidden. Resolution: HP P2000 primordial storage pools are no longer displayed. | TKU 2015-Mar-1 |
TKU-2438 | Problem: HP P6000 primordial storage pools should be hidden. Resolution: HP P6000 primordial storage pools are no longer displayed. | TKU 2015-Mar-1 |
TKU-2439 | Problem: Only IBM DS6000 series extend pools should be displayed. Resolution: Only IBM DS6000 series extend pools are now displayed. | TKU 2015-Mar-1 |
TKU-2430 | Problem: Some scanned IBM Storwize storage pools should be hidden. Resolution: IBM Storwize primordial storage pools are no longer displayed. | TKU 2015-Mar-1 |
TKU-3522 | Problem: Hitachi primordial storage pools should be hidden. Resolution: Hitachi primordial storage pools are no longer displayed. | TKU 2015-Mar-1 |
QM001870592 / TKU-3021 | Problem: Disk size is calculated incorrectly for the storage systems with sector size that is not equal to 4096. Resolution: Code fix. | TKU 2015-Mar-1 |
TKU-3022 | Problem: Incorrect column is used when retrieving total_blocks in raidVTable. Resolution: Code fix. | TKU 2015-Mar-1 |
QM001874188 / TKU-3691 | Problem: Storage discovery might cause an ECA error. Resolution: Code fix. | TKU 2015-Mar-1 |
QM001875191 / TKU-3725 | Problem: The NetApp storage file system is not linked to the host file system, when the storage filesystem is s qtree. Resolution: Code fix. | TKU 2015-Mar-1 |
QM001876656 / TKU-3726 | Problem: The NetApp storage file system is not linked to the host file system, when host filesystem has remote hostname as vfiler name. Resolution: Code fix. | TKU 2015-Mar-1 |
QM001871742 | Problem: BMC Discovery does not discover all network interfaces on storage device. Resolution: Fixed in the code. All network interfaces are discovered. | TKU 2015-Feb-1 |
QM001872042 | Problem : Discovery access of a storage devices shows "UNKNOWN_PythonException" for =getNetworkInterfaces= resulting in "0 Discovered Network Interfaces found" Resolution: Fixed in the code.Above failure is no more reported. | TKU 2015-Feb-1 |
TKU-2421 | Problem: NAA ID is not correct on Hitachi systems. Resolution: The disk array serial numbers used to generate the NAA ID are now shorten to 16bits to be properly handled by the TPL. | TKU 2015-Feb-1 |
TKU-2433 | Problem: HP 3 PAR primordial storage pools should be hidden. Resolution: HP 3 PAR primordial storage pools are no longer displayed. | TKU 2015-Feb-1 |
TKU-2440 | Problem: Should show the current state of the HP 3 PAR disk drives. Resolution: The Current State parameter is now available for all HP 3 PAR disk drives. | TKU 2015-Feb-1 |
TKU-2434 | Problem: The "spindle name" was used for identifying disks on VMAX-1SE Resolution: Fixed in the code. The product now relates on the ‘Disk ID.’ | TKU 2015-Jan-1 |
QM001867146 | Problem: NetApp_Storage.NetAppStorage pattern is giving ECA error when diskinfo speed is not a number Resolution: NetApp_Storage.NetAppStorage pattern now checks speed is an integer | TKU 2015-Jan-1 |
Comments