CDM Mapping for Storage
This topic provides information about mapping for storage. The CIs created are described in this topic.
Data models
CMDB version differences
The default mapping works with CMDB versions 7.5, 7.6, and 7.6.03 and later. The data model in each is slightly different.
BMC_Impact
relationships are not normally created with CMDB 7.6.03 and later, since the CMDB automatically maintains them itself. See the information about impact relationships for more details.
BMC_ComputerSystem
The StorageSystem node is mapped to the BMC_ComputerSystem CI.
BMC_ComputerSystem
Attribute | Details |
---|---|
Name | StorageSystem name |
ShortDescription | StorageSystem name |
Description | StorageSystem name |
CapabilityList | List of capabilities |
ManufacturerName | StorageSystem vendor |
Model | StorageSystem type:StorageSystem model |
isVirtual | True if the Storage System is virtual; not set if physical. |
PrimaryCapability | Storage |
SerialNumber | StorageSystem serial number |
Category | The CDM category, for example, "Hardware". |
Type | The CDM type, for example, "Disk device". |
Item | The CDM item, for example, "Disk array". |
BMC_ComputerSystem relationships
Populate the Company attribute for BMC_ComputerSystem CIs mapped from StorageSystem nodes.
Creates links to manager CI and sets LastScanDate and SystemOID where available.
Do not create an extension syncmapping that extends this one. If you need to access nodes accessed in the traversals here, traverse again. This priority syncmapping must complete before any other CIs are created.
- First-order Software Instances are mapped to BMC_SoftwareServer CIs.
- Second-order Software Instances are mapped to BMC_ApplicationSystem CIs.
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BMC_Dependency | STORAGEUSE | BMC_ComputerSystem Backend Storage System | BMC_ComputerSystem consuming NAS host
|
|
|
|
|
|
|
|
|
BMC_OperatingSystem
StorageSystem OS is mapped to BMC_OperatingSystem.
Attribute | Details |
---|---|
key | StorageSystem |
Name |
|
ShortDescription |
|
Description |
|
ManufacturerName | StorageSystem |
MarketVersion | StorageSystem |
Model | StorageSystem |
OSType | 0 (Other) |
VersionNumber | StorageSystem |
Company | StorageSystem |
Category | "Software" |
Type | "Operating System Software" |
Item | "Storage Operating System" |
BMC_OperatingSystem relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
BMC_ResourcePool
The StoragePool node is mapped to the BMC_ResourcePool CI.
BMC_ResourcePool
Attribute | Details |
---|---|
TokenId | Attribute that aids reconciliation of CIs populated by multiple data sources. TokenId is of the form "ADDM:StoragePool key". |
Name | StoragePool |
ShortDescription | StoragePool ID |
Description | StoragePool name |
AllocationUnits | "byte" |
Capacity | StoragePool capacity |
CurrentlyConsumedResource | StoragePool consumed capacity |
Primordial | If the pool type is primordial, "Primordial" |
ResourceType | 32=Storage Volume |
Company | StorageSystem Company |
Category | "Hardware" |
Type | "Storage" |
Item | "Storage pool" |
BMC_ResourcePool relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
BMC_HardwarePackage
The StorageProcessor node is mapped to the BMC_HardwarePackage CI.
From June TKU 2015 onwards Serial number attribute is added for StorageProcessor.
BMC_HardwarePackage
Attribute | Details |
---|---|
TokenId | Attribute that aids reconciliation of CIs populated by multiple data sources. TokenId is of the form "ADDM:StorageProcessor.key". |
Name | StorageProcessor |
ShortDescription | StorageProcessor identifier. |
Description | StorageProcessor description. |
ManufacturerName | StorageProcessor vendor. |
Model | StorageProcessor model name. |
Company | StorageProcessor company. |
Serial | StorageProcessor serial number. |
Category | "Hardware" |
Type | "Storage" |
Item | "Storage processor" |
BMC_HardwarePackage relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
BMC_NetworkPort, BMC_IPEndpoint and BMC_LANEndpoint
Each Network Interface node connected to the root StorageSystem in the Discovery model is mapped to a BMC_NetworkPort CI, and its MAC address is mapped to a BMC_LANEndpoint CI. Each of its associated IP addresses are mapped to BMC_IPEndpoint CIs.
BMC_NetworkPort
Attribute | Details |
---|---|
Name | Interface name of the Network Interface |
ShortDescription | Interface name of the Network Interface |
Description | Full name of the Network Interface |
AutoSense | Negotiation setting, 0=Yes, 1=No. |
FullDuplex | Full duplex, 0=Yes, 1=No. |
LinkTechnology | 2. (Ethernet) |
ManufacturerName | The Network Interface manufacturer |
PermanentAddress | MAC address. |
PortType | 2. (Ethernet) |
Speed | The interface speed in bps |
Company | Network Interface Company |
Category | "Hardware" |
Type | "Card" |
Item | "Network interface card" |
The front-end FibreChannelPort is mapped to BMC_NetworkPort.
Note that "Fibre Channel" is the correct spelling for the technology. Do not "correct" the Item to "Fiber Channel".
Attribute | Details |
---|---|
TokenId | Attribute that aids reconciliation of CIs populated by multiple data sources. TokenId is of the form "World Wide Name:World Wide Port Number". |
Name | Fibre Channel Port |
ShortDescription | Fibre Channel Port name |
Description | Fibre Channel Port name : WWPN |
LinkTechnology | 4. (Fibre Channel) |
ManufacturerName | Storage processor vendor |
Model | Storage processor model |
PermanentAddress | Fibre Channel Port WWPN |
PortType | 6. (Fibre Channel) |
Company | Host Company |
Category | "Hardware" |
Type | "Card" |
Item | "Fibre Channel HBA card" |
BMC_NetworkPort relationship
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
BMC_Component | SUBHWCOMPONENT |
| BMC_NetworkPort |
BMC_LANEndpoint
Attribute | Details |
---|---|
Name | MAC Address |
NameFormat | "MAC" |
ShortDescription | MAC Address (with colons) |
Description | "MAC address on hostname" |
Address | MAC address (no separating colons) |
MACAddress | MAC address (no separating colons) |
ProtocolType | 14. (Ethernet) |
Company | Network Interface Company |
Category | "Network" |
Type | "Address" |
Item | "MAC Address" |
BMC_LANEndpoint relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
|
|
|
|
BMC_IPEndpoint
Attribute | Details |
---|---|
Name | IP address |
NameFormat | "IP" |
ShortDescription | IP address |
Description | IP address |
AddressType | IPv4 (1) or IPv6 (2) |
Address | IP address |
DNSHostName | IP address |
ManagementAddress | Yes (1) if the IP address was used to scan the host; No (0) if not. (Not in CMDB 7.5.) |
ProtocolType | IPv4 (2) or IPv6 (3) |
PrefixLength | IPv6 prefix length in bits |
SubnetMask | IPv4 subnet mask |
Company | Network Interface Company |
Category | "Network" |
Type | "Address" |
Item | "IP Address" |
BMC_IPEndpoint relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
BMC_IPConnectivitySubnet
The Subnet node is mapped to BMC_IPConnectivitySubnet.
Attribute | Details |
---|---|
Name | Subnet |
ShortDescription | Subnet |
Description | Subnet |
SubnetNumber | Subnet |
AddressType | IPv4 (1) or IPv6 (2) |
PrefixLength | IPv6 prefix length in bits |
SubnetMask | IPv4 subnet mask |
Company | Subnet Company |
Category | "Network" |
Type | "Subnet" |
Item | "TCP/IP" |
BMC_IPConnectivitySubnet relationships
Relationship | Name | Source | Destination |
---|---|---|---|
BMC_InIPSubnet | INIPSUBNET | BMC_IPConnectivitySubnet | BMC_IPEndpoint |
BMC_Cluster
The StorageSystemGroup node is mapped to the BMC_Cluster CI.
Attribute | Details |
---|---|
TokenId | Attribute that aids reconciliation of CIs populated by multiple data sources. TokenId is of the form "ADDM:StorageSystemGroup key". |
Name | StorageSystemGroup name. |
ShortDescription | StorageSystemGroup name. |
Description | StorageSystemGroup name. |
ManufacturerName | StorageSystem vendor. |
Model | StorageSystemGroup type. |
Company | StorageSystemGroup Company. |
Category | "Hardware" |
Type | "Storage" |
Item | "Storage cluster" |
Where clustered, the StorageSystem node is also mapped to the BMC_Cluster CI.
Attribute | Details |
---|---|
TokenId | Attribute that aids reconciliation of CIs populated by multiple data sources. TokenId is of the form "ADDM:Device key". |
Name | StorageSystem name. |
ShortDescription | StorageSystem name. |
Description | StorageSystem name. |
ManufacturerName | StorageSystem vendor. |
Model | StorageSystem type. |
Company | StorageSystem Company. |
Category | "Hardware" |
Type | "Storage" |
Item | "Storage cluster" |
BMC_Cluster relationships
Relationship | Name | Source | Destination |
---|---|---|---|
|
|
Impacted |
|
Comments
Log in or register to comment.