Planning a DELTA List Creation from Stage-1 Macros
-
Assembler H Version 2 is required.
-
No user verification or keyword table validation is performed when creating DELTA Lists from IMS Stage-1 macros. Anyone with write access to the DELTA PDS data set can create a DELTA List. All keywords and parameters are allowed and are placed in the DELTA List.
-
If the DELTA IMS Convert utility is subsequently used to convert the DELTA List to IMS Stage-1 macros, the macros created will not necessarily match the macros used to create the DELTA List.
-
The DELTA List assembly step may result in a nonzero return code. MNOTEs in the assembly listing will explain the error. RC=8 indicates a syntax error--defaults are used instead of the value specified. RC=4 indicates a missing or an extraneous value. If a value is missing, the default is used. An extraneous value is ignored.
Comments