Control-M/EM PANFT.9.0.21.002
BMC Software is releasing patch PANFT.9.0.21.002 to correct several problems in Control-M/EM 9.0.21.000 for UNIX and Windows.
Corrected Problems
The following table describes the corrected problems that are fixed in PANFT.9.0.21.002:
Tracking number | Description |
---|---|
CTM-4521 | The Service tab in the Monitoring domain becomes inactive after a period of idle time. |
CTM-7472 | The Run as User Enter Password field in the Run as Users Authentication Settings window in the CCM remains empty and when trying to update causes all jobs that run by this user to fail when Compatibility mode is on. |
CTM-7494 | The following issues are detected in NodeJs:
|
CTM-7418 | The periodic calendar does not properly appear in View Schedule in Control-M Web when the first period does not start on the first day of the month. |
CTM-7498 | The wrong report in the Folder Manager might run when the browser language is set to United Kingdom English. |
CTM-7465 | The following error message appears in Automation API when you run a Jobs Definitions category report: |
CTM-7416 | Issue CVE-2022-37614 is detected in the Control-M command line interface. |
CTM-7496 | Security vulnerability CVE-2022-7501 is detected in Control-M/EM. |
CTM-7398 | A search in Control-M Workload Archiving 9.0.21.000 does not return all rows of job logs for cyclic jobs with a rerun count greater than 5. To resolve this issue, you must apply Control-M/Server patch PACTV.9.0.21.002. |
CTM-7386 | SSL encryption might not work after you upgrade Control-M/EM 9.0.20 to 9.0.21 in a One Install configuration. |
CTM-7500 | Vulnerabilities are detected in the ESS package password (bmcryptpw utility). |
Installing the Patch on UNIX/Linux
This procedure describes how to install patch PANFT.9.0.21.002 on UNIX/Linux.
Before You Begin
- Verify Control-M/EM version 9.0.21.000 is installed.
- Obtain the installation package via EPD, as described in Obtaining Control-M Installation Files via EPD.
Begin
- Log in as the Control-M/EM user.
- Copy the patch installation file that you obtained into a temporary directory.
- Set execution flags for the patch installation file using the following command:
chmod +x PANFT.PANFT.9.0.21.002_<platform>_INSTALL.BIN - Stop all Control-M/EM components.
- Run the following script from the Control-M/EM Home directory:
<temporary directory>/PANFT.9.0.21.002_<platform>_INSTALL.BIN - Follow the on-screen instructions until the installation is complete.
- Start all Control-M/EM components.
Installing the Patch on Windows
This procedure describes how to install patch PANFT.9.0.21.002 on Windows.
Before You Begin
- Verify Control-M/EM version 9.0.21.000 is installed.
- Obtain the installation package via EPD, as described in Obtaining Control-M Installation Files via EPD.
Begin
- Stop all Control-M/EM components.
- Double-click the downloaded patch installation file.
- Follow the on-screen instructions until the installation is complete.
- Start all Control-M/EM components.
Installing the Patch using Client Distribution on UNIX/Linux
This procedure describes how to install PANFT.9.0.21.002 using Client Distribution.
Begin
- From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
cd $EM_HOME%/bin - Run the following utility:
em deploy_client_patch -U <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>/PANFT.9.0.21.002 - Log in to the CCM, and set the patch for deployment.
- From the Manage tab, click Client Distribution.
- Select the Fix Packs tab.
- Select PANFT.9.0.21.002.
When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.
Installing the Patch using Client Distribution on Windows
This procedure describes how to install PANFT.9.0.21.002 using Client Distribution.
Begin
- From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
cd %EM_HOME%\bin - Run the following utility:
deploy_client_patch.bat -U -P \ <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>PANFT.9.0.21.002_windows_x86_64.exe64-bit Example:
deploy_client_patch.bat -U emuser -P myPassword C:\PANFT.9.0.21.002\PANFT.9.0.21.002_windows_x86_64.exe - Log in to the CCM, and set the patch for deployment.
- From the Manage tab, click Client Distribution.
- Select the Fix Packs tab.
- Select PANFT.9.0.21.002.
When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.
Uninstalling the Patch from UNIX/Linux
This procedure describes how to uninstall patch PANFT.9.0.21.002 from UNIX/Linux.
Begin
- Stop all Control-M/EM components.
- Navigate to the following directory:
<USER_HOME>/install/PANFT.9.0.21.002 - Run the following script:
uninstall.sh - Start all Control-M/EM components.
Uninstalling the Patch from Windows
This procedure describes how to uninstall patch PANFT.9.0.21.002 from Windows.
Begin
- Stop all Control-M/EM components.
- From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager PANFT.9.0.21.002 (<instance name>).
- Select Uninstall.
- Start all Control-M/EM components.