Control-M/EM PANFT.9.0.21.001
BMC Software is alerting you to a number of issues detected in Control-M/EM and Control-M Web.
Patch PANFT.9.0.21.001 corrects these problems. This patch is installed on top of Control-M/EM version 9.0.21.000 on UNIX/Linux or Windows.
You must install this patch on every environment where a Control-M/Enterprise Manager Server is installed.
Corrected Problems
The following table describes the corrected problems included in patch PANFT.9.0.21.001:
Tracking number | Description |
---|---|
CTM-7443 | Security vulnerability CVE-2022-42889 detected in a library used by Control-M/EM services. |
CTM-7431 | If you run an ad hoc job in a folder that contains more than 10 jobs, a different job from the same folder might be run. This occurs if Control-M/EM and Control-M/Server are both version 9.0.21. |
CTM-7430 | Permissions for the following actions on services in the Monitoring domain are not enforced correctly:
|
CTM-7424 | Usage report data might not be collected by the Configuration Management Server (CMS). |
CTM-7434 | Days in a periodic calendar or regular calendar are incorrect or are shifted by one day when you use the recurrence option to mark weekdays and the language in the browser is not US English. |
CTM-7361 | The tree in the navigation pane of a viewpoint in Control-M Web is displayed with incorrect hierarchy when you open a viewpoint with non-default grouping and grouping is turned on. |
Installing the Patch on UNIX/Linux
This procedure describes how to install patch PANFT.9.0.21.001 on UNIX/Linux.
Before You Begin
- Verify that Control-M/EM version 9.0.21.000 is installed.
- Obtain the installation package via EPD, as described in Obtaining-Control-M-Installation-Files.
Begin
- Log in as the Control-M/EM user.
- Copy the patch installation file that you obtained into a temporary directory.
- Set execution flags for the patch installation file using the following command:
chmod +x PANFT.9.0.21.001_<platform>_INSTALL.BIN - Run the following script from the Control-M/EM Home directory:
<temporary directory>/PANFT.9.0.21.001_<platform>_INSTALL.BIN - Follow the on-screen instructions until the installation is complete.
Installing the Patch on Windows
This procedure describes how to install patch PANFT.9.0.21.001 on Windows.
Before You Begin
- Verify that Control-M/EM version 9.0.21.000 is installed.
- Obtain the installation package via EPD, as described in Obtaining-Control-M-Installation-Files.
Begin
- Double-click the downloaded patch installation file.
- Follow the on-screen instructions until the installation is complete.
Uninstalling the Patch from UNIX/Linux
This procedure describes how to uninstall patch PANFT.9.0.21.001 from UNIX/Linux.
Begin
- Navigate to the following directory:
<EM_HOME>/install/PANFT.9.0.21.001 - Run the following script:
uninstall.sh
Uninstalling the Patch from Windows
This procedure describes how to uninstall patch PANFT.9.0.21.001 from Windows.
Begin
- From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager 9.0.21.000 Patch 1 (<instance name>).
- Select Uninstall.