Control-M/EM PANFT.9.0.20.220


BMC Software is alerting you to a security vulnerability detected in Control-M Reports.

CTM-7355: The Log4j2 libraries in Control-M Reports are out-of-date and must be upgraded to a recent version.

Patch PANFT.9.0.20.220 corrects this problem. This patch is installed on top of Control-M/EM version 9.0.20.214 on UNIX/Linux or Windows

You must apply this patch on every Control-M/EM Server installation.

Installing the Patch on UNIX/Linux

This procedure describes how to install patch PANFT.9.0.20.220 on UNIX/Linux.

Before You Begin

Begin

  1. Copy the patch installation file that you obtained into a temporary directory.
  2. Set execution flags for the patch installation file using the following command:
    chmod +x PANFT.9.0.20.220_<platform>_INSTALL.BIN
  3. Run the following script from the Control-M/EM Home directory:
    <temporary directory>/PANFT.9.0.20.220_<platform>_INSTALL.BIN
  4. Follow the on-screen instructions until the installation is complete.

Installing the Patch on Windows

This procedure describes how to install patch PANFT.9.0.20.220 on Windows.

Before You Begin

Begin

  1. Double-click the downloaded patch installation file.
  2. Follow the on-screen instructions until the installation is complete.

Uninstalling the Patch from UNIX/Linux

This procedure describes how to uninstall patch PANFT.9.0.20.220 from UNIX/Linux.

Begin

  1. Navigate to the following directory:
    <EM_HOME>/install/PANFT.9.0.20.220
  2. Run the following script:
    uninstall.sh

Uninstalling the Patch from Windows

This procedure describes how to uninstall patch PANFT.9.0.20.220 from Windows.

Begin

  1. From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager 9.0.20.200 Patch 20 (<instance name>).
  2. Select Uninstall.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

Control-M 9.0.20