Setting IMSID options when installing DELTA PLUS or DELTA PLUS VIRTUAL TERMINAL.
You should set IMSID options if you are performing an initial installation of DELTA PLUS or DELTA PLUS VIRTUAL TERMINAL.
You must create IMSID basic options for each control region that the products service. For more information, see To set IMSID options.
For the products to access an IMS system, you must define the system to the products with a set of IMSID options. When you create or change IMSID options, the load module DLP#iiii (where iiii is the IMSID) is link-edited to your product options library.
You can create a new IMSID by using the product defaults or by copying the options for a new IMSID from an existing IMSID. For more information, see To create a new IMSID.
DELTA PLUS VIRTUAL TERMINAL includes IMSID options that are not available with DELTA PLUS. For additional IMSID options that you can set for DELTA PLUS VIRTUAL TERMINAL, see Setting virtual terminal IMSID options.
Note
BMC recommends the following regarding the IMSID options modules:
Use the APF-authorized library to provide both ISPF and IMS with access to the IMSID options modules.
Do not use a LINKLIST library to store the IMSID options modules
Save IMSID options modules in the same library with the global and Group options (if used) modules.
If you have an existing DELTA IMS IMSID options module (DLA#iiii), certain IMSID options module fields can be copied from DLA#iiii. For more information, see the conversion appendices in the product user guide.
To create a new IMSID
- Invoke the online interface through the modified ISPF/PDF Primary Option Menu that you created in Accessing the products from an ISPF options menu or through the CLIST that you created in Accessing the products from a CLIST.
The Main Menu is displayed.
- Type 4 in the selection field and press Enter.
The Administration Menu is displayed.
- Type 2 in the selection field and press Enter.
The IMSID/Group Options Entry panel is displayed.
Menu Options Help ------------------------------------------------------------------------------- DELTA PLUS IMSID/Group Options Entry Command ===> _________________________________________________________________ Choose a selection: _ 1. Edit IMSID Options 2. Edit Group Options Specify Options information: Options library . . . . . 'ABC.DLP.OPTIONS.LOAD' IMSID or Group. . . . . . ____ (blank for selection list) Specify additional libraries in which to save Options (if desired): Save library 1. . . . . . ______________________________________________ Save library 2. . . . . . ______________________________________________
- Determine the method that you want to use to create the new IMSID:
- Type the name of the new IMSID in the IMSID or Group field and press Enter.
The IMSID options will be populated from internal product defaults.
- Type the name of the new IMSID in the IMSID or Group field and press Enter.
If you are installing DELTA PLUS, the DELTA PLUS Edit IMSID Options panel is displayed.
If you are installing DELTA PLUS VIRTUAL TERMINAL, the DELTA PLUS VIRTUAL TERMINAL Edit IMSID Options panel is displayed.
DELTA PLUS VT IMSID Options - Basic Options Command ===> _________________________________________________________________ IMSID . . . . . . . . . . . : IMSA More: + Display/Zap Options. Select if desired. / Allow IMS storage displays / Allow IMS storage zaps Save Options. Select if desired. _ Copy IMSID Options to an IMS STEPLIB library when saved IMS STEPLIB library . . . . ______________________________________________ XRF/FDR Alternate IMSID . . . ____ (If changed, IMS restart is required) XCF Group (optional) . . . . ____ (If changed, IMS cold-start is required) IMS Restart Options (if XCF Group specified above). Select if desired. _ Do not issue WTOR for coordinated request errors
File Edit Refresh Options Help ------------------------------------------------------------------------------- DELTA PLUS VT Edit IMSID Options Command ===> __________________________________________________________________ IMSID . . . . . . . . . . . : WXC5 IMSID options. Choose a selection. _ 1. Basic - Info required for DELTA PLUS VT operation _ 2. VT Limits - Limits for virtual terminals _ 3. VT Options - Options for virtual terminals _ 4. VT TSS - TSS tables for virtual terminals _ 5. VT Logon - Logon for virtual terminals _ 6. VT Signon Bypass - Signon Bypass for virtual terminals _ 7. VT Signon - Signon for virtual terminals _ 8. Extended Options - DELTA PLUS VT extended options
- Type COPY name on the Command line (where name is the name of the existing IMSID from which you want to copy the IMSID options) and press Enter.
The new options will be copied from the existing IMSID.
To update IMSID options in the control region
- Invoke the online interface through the modified ISPF/PDF Primary Option Menu that you created in Accessing the products from an ISPF options menu or through the CLIST that you created in Accessing the products from a CLIST.
The Main Menu is displayed.
- Type 4 in the selection field and press Enter.
The Administration Menu is displayed.
- Type 5 in the selection field and press Enter.
The Refresh Menu is displayed.
Menu Options Help ------------------------------------------------------------------------------- DELTA PLUS Refresh Menu Command ===> _________________________________________________________________ Refresh Option. Choose a selection. _ 1. Options - Refresh IMSID or Group Options 2. CPU-id - Refresh CPU-id Specify Target. IMSID or Group . . ____
- Type 1 in the selection field.
- In the IMSID or Group field, type the IMSID that you want to update and press Enter.
The Confirm Options Refresh pop-up window is displayed.
- Type 1 in the selection field and press Enter.
The product refreshes the IMSID options.
To set IMSID options
- Invoke the online interface through the modified ISPF/PDF Primary Option Menu that you created in Accessing the products from an ISPF options menu or through the CLIST that you created in Accessing the products from a CLIST.
The Main Menu is displayed.
- Type 4 in the selection field and press Enter.
The Administration Menu is displayed.
- Type 2 in the selection field and press Enter.
The IMSID/Group Options Entry panel is displayed.
- Type 1 in the selection field.
- Type the data set name of the library in which the IMSID options module (DLP#iiii) will reside in the Options library field.
For information about allocating this data set, see Allocating new data sets.
- Perform the appropriate action.
Activity
Action
Indicate a specific IMSID for the IMS system that you want to customize or access.
Type the IMSID of the IMS system in the IMSID or Group field. This action is required for the first set of IMSID options.
Choose an IMSID that you want to customize or access from a list of IMSIDs.
Leave the IMSID or Group field blank.
(optional) If your installation stores IMSID/Group options modules in separate libraries that are used by ISPF, the control region, or BMCXLINK, type the data set name of the additional library in which to store the IMSID options modules in the Save library 1 field and press Enter.
Note
If you use several load libraries, remember that it is possible to have a copy of a module in more than one library. IMS will use the first module that it finds, regardless of whether that module is the most current one available.
If you typed a specific IMSID in the IMSID or Group field, the Edit IMSID Options panel is displayed. Go to Step 9.
If you left the IMSID or Group field blank, the Edit IMSID Options – List panel is displayed, allowing you to select an IMSID. Go to Step 8.
File Help ------------------------------------------------------------------------------- prd Edit IMSID Options - List Row 1 to 16 of 22 Command ===> ________________________________________________ Scroll ===> PAGE Options Library . . : 'ABC.prd.OPTIONS.LOAD' Enter S to edit the IMSID options. _ ABCD _ BAD1 _ GCB5 _ MJD5 _ NEW _ PXMI _ TEST _ WXCA
- Perform one of the following actions:
Create a new IMSID options module by typing S newimsid on the Command line.
Modify an existing set of options by typing S next to an existing IMSID.
Press Enter.
If you are installing DELTA PLUS, the DELTA PLUS Edit IMSID Options panel is displayed. Go to Step 9.
If you are installing DELTA PLUS VIRTUAL TERMINAL, the DELTA PLUS VIRTUAL TERMINAL Edit IMSID Options panel is displayed. Go to Step 9.
- Type 1 in the selection field and press Enter.
The IMSID Options – Basic Options panel is displayed. The fields on this panel are the same as the fields on the DELTA PLUS Edit IMSID Options panel.
The following fields are available on this panel:
IMSID
The IMSID of the options module that you selected.
Allow IMS storage displays
Type a / in the selection field to enable the storage display feature for this IMS system. You can use internal security to restrict usage of this feature.
Allow IMS storage zaps
Type a / in the selection field to enable the storage alteration (zap) feature for this IMS system. The storage zap feature is a powerful tool for correcting problems within the IMS system. However, you should use internal security to restrict usage of this feature.
Copy IMSID options to an IMS STEPLIB library when saved
Type a / in the selection field to copy IMSID options modules to an IMS //STEPLIB library when the module is saved in the options library.
If you select this option, you must specify the name of the IMS //STEPLIB library in which to store the modules that are used by the control region in the IMS STEPLIB library field.
IMS STEPLIB library
Specify the name of the IMS //STEPLIB library in which to store the modules that are used by the control region.
If your installation stores IMSID options modules in separate libraries for use by ISPF and IMS, you should complete this field. If both ISPF and IMS use the same library, this field is optional.
XRF/FDR Alternate IMSID
Specify the IMSID of the IMSGEN-defined XRF alternate system or the IMSID of the FDR control region .
For information about enabling the FDR feature, see Enabling the FDR feature (DELTA PLUS and DELTA PLUS VIRTUAL TERMINAL).
XCF Group
Specify the name of the Group to which this IMS system belongs. This field is optional because an IMS system does not have to belong to a Group.
Do not issue WTOR for coordinated request errors
Type a / in the selection field to ensure that the WTOR (write to operator with reply) message
BMC186124A Errors applying new request from Log, should restart continue? Reply 'Y' or 'N'
is not issued at IMS restart if a coordinated request fails.Reply Y or N for any new coordinated requests that have errors at restart. Error messages are still issued for coordinated request errors.
BMCXLINK task network LUNAME
Type a network LUNAME for the BMCXLINK VTAM subtask. The LUNAME that you specify MUST match the LUNAME that is specified in the PARM field of the BMCXLINK task. The default value for this field is DLPALINK.
Primary Log
Type the data set name of the primary Log data set. You must cold-start IMS for this change to take effect.
Secondary Log
Type the data set name of the secondary Log data set. You must cold-start IMS for this change to take effect.
Primary History File
Type the data set name of the primary History File data set. You must restart IMS for this change to take effect.
Secondary History File
Type the data set name of the secondary History File data set. You must restart IMS for this change to take effect.
Write IMS commands to History File
Type a / in the selection field to send IMS operator commands that are issued from a DELTA List or from the Execute IMS Command panel to the History File.
(optional) Primary Repository
Type the name of the primary DELTA PLUS Repository data set.(optional) Secondary Repository
Type the name of the secondary DELTA PLUS Repository data set.
Press F3 to save changes to the IMSID options.
Note
If you specified an existing IMSID in the XRF/FDR Alternate IMSID field, the Confirm Delete pop-up window is displayed before the IMSID options are saved.
Type 1 in selection field and press Enter to delete the existing options for the IMSID previously specified in the XRF/FDR Alternate IMSID field. This selection also makes the IMSID that is specified in the XRF/FDR Alternate IMSID field the alternate for the IMSID that you are editing.
Comments
Log in or register to comment.