Commands available on the View Profile Field Edit panel
PROMPT displays the available values for the field on which the cursor currently resides.
To create a View Profile
- From the DELTA PLUS Main Menu, type 4 in the selection field and press Enter. The Administration Menu is displayed.
- Type 3 in the selection field and press Enter. The View Profile Edit Entry panel is displayed.
- Type the name of the View Profile in the View Profile field and press Enter.
Type a / in the field next to each element type that you want to edit.The View Profile Element Edit panel will display for the first element type selected.
Note
The View Profile Element Edit panel displays different fields for the various element types. All fields displayed on any View Profile Element Edit panel are listed in the following table.
- Edit the following fields, as necessary:
Field name
Description
View Profile
Displays the name of the View Profile you are creating or modifying. This is not an editable field.
Element Type
Displays the type of DELTA List element. Valid types are
APPLCTN
TRANSACT
DATABASE
TERMINAL
LTERM
RTCODE
SUBPOOL
COMMAND
DELTALST
This is not an editable field.
Description
Type a description of the DELTA list element type. The default descriptions for each element type are
APPLCTN – Define program directory entry
TRANSACT – Define transaction code
DATABASE – Define database directory entry
TERMINAL – Define VTAM terminal
LTERM – Define logical terminal
RTCODE – Define Fast Path routing code
SUBPOOL – Define VTAM LU 6.1 SUBPOOL
COMMAND – Execute IMS operator command
DELTALST – Include another DELTA list
Field Order
Specify the Field ID number of each field in the order you want the fields to appear on the DELTA List Element Edit panel.
Element Access
Indicate whether to prohibit users of this View Profile access to the element type or to allow edit access.
Type 1 to allow edit access for the element type.
Type 2 to prohibit access to the element type.
Marked for Execution
Type a / in this field to indicate that any element of this type that is in the DELTA List should be included when the DELTA List is processed.
If this field is selected, by default, when an element of this type is added in a DELTA List it is automatically included in the execution of that DELTA List.
Stop program before change
Type a / in this field to indicate that the command should be executed, by default, for any element of this type when the DELTA List is processed.
If this field is selected, by default, an element of this type in a DELTA List is stopped before the change for that element is executed. For example, it is advisable on a Revise DELTA action to stop the program before executing the Revise action.
Note
DELTA IMS will internally issue the /DBR NOFEOV command for the DATABASE element, and /STO for all other applicable element types. If this process does not sufficiently address your requirements, additional COMMAND elements can be used.
Be aware that when performing a Fast Path database change, the /DBR command issued by DELTA IMS will take an extended amount of time if the database contains many areas. This is not an anomaly. IMS processing of the /DBR command, not DELTA IMS processing, causes the extended amount of time.
Start program after change
Type a / in this field to indicate that the command should be executed, by default, for any element of this type when the DELTA List is processed.
If this field is selected, by default, an element of this type in a DELTA List is /STArted after the change for that element is completed.
Force update when queue count > 0
This field is valid only for the TRANSACTION element type. It will not appear on the panel for the other element types.
Type a / in this field to indicate the forcing of this change, by default, for any element of this type when the DELTA List is processed.
If this field is selected, by default, this option allows the desired change to any element of this type in the DELTA List even if the IMS queue count is greater than zero.
Note
The Force option is ignored for requests that rename the transaction, revise the transaction from local to remote or vice versa, a conversational transaction where the SPA size is changed, or transactions that are changed to or from Fast Path.
Command defaults
This field is valid only for the COMMAND element type. It will not appear on the panel for the other element types.
Use this field to set the default value for when an IMS command should be executed in relation to the execution of the DELTA List in which the command element is included.
Type 1 to execute the command before DELTA List execution.
Type 2 to execute the command after DELTA List execution.
Type a / in the selection field next to each element attribute for which you want to edit the default values. The View Profile Field Edit panel will display for the first element attribute field selected.
Note
The View Profile Field Edit panel displays different fields depending upon which element attribute field was selected for editing. All fields displayed on any View Profile Field Edit panel are listed in the following table.
- Edit the following fields, as necessary:
Field name
Description
View Profile
Displays the name of the View Profile you are creating or modifying. This is not an editable field.
Element Type
Displays the type of DELTA List element. Valid types are:
APPLCTN
TRANSACT
DATABASE
TERMINAL
LTERM
RTCODE
SUBPOOL
COMMAND
DELTALST
This is not an editable field.
Field ID
The Field ID is a sequential ID number of each element attribute field that appears for the element type on the DELTA List Element Edit panel. This is not an editable field.
Field Name
Displays the name of the element attribute field you are modifying. This is not an editable field.
Macro
Specify the corresponding IMS macro statement for this element attribute field.
Description
Type a user-defined description of this element attribute field.
Field access
Indicate whether to prohibit users of this View Profile access to this element attribute field, or to allow read-only or edit access.
Type 1 to allow edit access for this field.
Type 2 to allow read-only access for this field.
Type 3 to prohibit access to this field.
Default value
This field is not applicable to all element attribute fields.
Specify a default value for the element attribute field.
Select field for revise
This field is not applicable to all element attribute fields.
Type a / in this field to indicate that this element attribute field should be selected for revise when an element of this type is added to a DELTA List with a DELTA action of REVISE.
If this field is selected, by default, this element attribute field will be selected for revise when an element of this type is added with a DELTA action of REVISE.
Comment
This field is applicable only to the comment element attribute fields.
Use this field to provide any miscellaneous comments about this element type or any of the element attribute fields.
Remarks
Type any miscellaneous comments about this element attribute field.
- Press F3.
Previous action
Result
You selected more than one element attribute field for editing.
The View Profile Field Edit panel is displayed for the next field. Repeat step 7 and step 8 until the View Profile Element Edit panel is displayed for the element type selected for editing. Go to step 9.
You selected only one element attribute field for editing.
The View Profile Element Edit panel is displayed for the element type selected for editing. Go to step .
- Press F3.
Previous action
Result
You selected more than one element type for editing.
The View Profile Element Edit panel is displayed for the next element type. Repeat steps step 5 through 8 until the View Profile Edit panel is displayed. Go to step 10.
You selected only one element type for editing.
The View Profile Edit panel is displayed. Go to step 10.
- Save your changes.
- Press F3. The Confirm View Profile Save pop-up window is displayed.
- Type 1 in the selection field and press Enter. DELTA PLUS saves the View Profile.
- Press F3 twice (or three times if you are on the member selection list panel). The DELTA PLUS Main Menu is displayed.
Comments
Log in or register to comment.