Running the Configuration Check utility in GUI mode
This mode provides an interactive way through which you can set your configuration check preferences, select components and checks, run the checks, and view the result as an HTML Report.
The following topics are provided:
Before you begin
-
- Extract the configcheckerversionNumber_buildNumber.zip file before running the utility.
- Run the pre-upgrade checks by using the same version of Configuration Check utility as that of BMC Remedy AR System server to which you want to upgrade.
To run the BMC Remedy Configuration Check utility in GUI mode
Run the following file from the configchecker folder:
(Microsoft Windows) configchecker-ui.bat
(UNIX) configchecker-ui.sh
Note
For UNIX, provide executable permissions to configchecker-ui.sh. Use any X-Server utility (for example, MobaXterm) to start the configuration check GUI.
The following window is displayed:
Complete the fields that require inputs.
The configuration is saved in the configchecker_config.xml file. If you change the configuration, the configuration file is saved as a new file, and subsequent changes are made to that file. (The original configuration file that is shipped with BMC Remedy AR System is backed up as a separate file.)Click Next to open a window that displays all available checks based on the inputs that you provided in the previous window.
Some of the inputs are displayed in read-only mode at the top of this window. The Summary tab displays the precheck name, the product for which the check will be run, and the status of the check.
Note
When you click Next, the AR Server, Temp Dir, and AR Install Dir fields are validated. If an error occurs, you must resolve it before going to the next window.
The following window is displayed:
Select the required prechecks, and click Run to execute the selected checks.
After the checks are executed:
If all checks pass, no messages are displayed on the Details tab.
If errors or warnings are present, they are displayed in detail on the Details tab.
For failed checks, in the GUI mode a Hints column is displayed, containing information about errors that occur.
In the GUI mode, hint messages are displayed when the check condition fails. However, hint messages are not displayed when the initialization of check fails. For example, in a database-related check, if a database login fails, the intended condition cannot be checked. In such a case, a hint message is not displayed.
The detailed report generated after running the checks can be viewed in the HTML format by clicking the HTML Report button. The Configuration Check HTML Report displays the Pre Check Summary and Details tabs. For details, see Viewing configuration check reports.
Where to go from here
Viewing configuration check reports
Viewing configuration check log files and changing logging level
Related Topics
Running the Configuration Check utility in interactive command-line mode