You can stop a monitor service by one of the following actions:

  • Stop the monitor request with a Z line command. Use the Z line command from the AT or MONACTV view.
  • Set a stop time for automatic completion of data collection. Specify the STOP value (as a time stamp or interval count) on the Start or Modify panel for the monitor. The collected data remains available for viewing until the monitor is purged.
  • Purge a request from the Monitors Active list with a P line command. Use the P line command from the AT or MONACTV view.
  • Purge a service request with a PRG request. Issue a PRG request from BBPARM (see Automatic-startup-of-multiple-requests) or a BMC AMI Ops Automation EXEC (a BMC AMI OpsA product must be installed) as follows:

PRG=reqid|ALL

  • Stop a service with a timer request. Use the STOP or STOPCNT parameter. An example follows:


REQ=#PROC,START=00:11:00,STOP=00:12:00,LOG=ATSTOP,I=00:01:00

The request starts at 11 minutes after midnight and stops 12 minutes after midnight; the PLOT display is logged to the BBI-SS PAS Image log when the request stops. For more information, see Keyword-parameters.


 