Affinity factor example one
- All BBI-SS PASs are running with ACONCICS=YES set in their respective BBISSP00 parameter members.
- All BBI-SS PASs are running with DYNTGT=NO set in their respective BBISSP00 parameter members (indicating that TGTDEFs will have no affect on the systems).
- The UBBPARM data set for PASA and PASB contains:
- A BBIJNT00 member with no IBM CICS entries
- A CMRDTL00 member with an entry for each of the production CICS regions (CICS01-CICS60) only
- The UBBPARM data set for PASC contains:
- A BBIJNT00 member with no CICS entries
- A CMRDTL00 member with an entry for each of the test CICS regions (CICS61-CICS72) only
- None of the CICS regions use either the INITPARM SIT parameter or a BBIJNT00/BMCICS00 to indicate to the region which PAS it is to use.
Case 1.A—a new production CICS region (CICS52) becomes active
Because the CICS region does not have a directive to use a specific BBI-SS PAS, it places a request into the common communications request queue. This element is picked up by one of the three BBI-SS PASs, which determines that it should connect to PASB based upon the following accumulated affinity weights:
PAS | Weights | Description |
|---|---|---|
PASA | 1024 -270 3072 3826 | Initial weight Weight for each connected CICS region (negative) Weight for BBI-SS PAS having CMRDTL00 entry for the region Total weight for BBI-SS PAS |
PASB | 1024 -240 3072 3856 | Initial weight Weight for each connected CICS region (negative) Weight for BBI-SS PAS having CMRDTL00 entry for the region Total weight for BBI-SS PAS |
PASC | 1024 -50 974 | Initial weight Weight for each connected CICS region (negative) Total weight for BBI-SS PAS |
Case 1.B—a new test CICS region (CICS66) becomes active
Because the CICS region does not have a directive to use a specific BBI-SS PAS, it places a request into the common communications request queue. This element is picked up by one of the three BBI-SS PASs, which determines that it should connect to PASC based upon the following accumulated affinity weights:
PAS | Weights | Description |
|---|---|---|
PASA | 1024 -270 754 | Initial weight Weight for each connected CICS region (negative) Total weight for BBI-SS PAS |
PASB | 1024 -240 784 | Initial weight Weight for each connected CICS region (negative) Total weight for PAS |
PASC | 1024 -50 3072 4046 | Initial weight Weight for each connected CICS region (negative) Weight for BBI-SS PAS having CMRDTL00 entry for the region Total weight for BBI-SS PAS |