Step 7. Specify target and distribution zone information


The screen shown in the following figure is displayed after you press Enter in the previous step. Because in this sample order File-AID was the first selected product, the following figure represents File-AID. If you selected another product as the first in your order, it will be shown. When additional products are being installed, this screen will be redisplayed for each product in succession. The values from this screen are used in generating the installation JCL.

Specifying target and distribution zone information

                        BMC Installer
Command ===> __________________________________________________ Scroll ===> PAGE


Enter SMP/E and Zone information for: BMC AMI DevX File-AID Common Components.   
Press Enter to continue or PF3 to return to previous panel.


SMP/E HLQ:                    SYS1.CPWR.MXVJ170
Edit SMP/E dataset info?:     N


Distribution Zone Name:       XVJ170D
DZone CSI dataset name:       SYS1.CPWR.MXVJ170.DZ.CSI
DZone CSI currently does not exist
DZone datasets HLQ:           SYS1.CPWR.MXVJ170
Edit DZone dataset info?:     N


Target Zone Name:             XVJ170T
TZone CSI dataset name:       SYS1.CPWR.MXVJ170.TZ.CSI
TZone CSI currently does not exist
TZone datasets HLQ:           SYS1.CPWR.MXVJ170
Edit TZone dataset info?:     N


Install Japanese components?: N

The fields are pre-filled based on the product being installed. You can edit the displayed values for HLQs and dataset names. Parameters specified here apply only to the product listed near the top of the screen.

The Install Japanese components? field displays only if separate Japanese components are provided with the selected product.

  1. If you want to make changes to specific dataset information, proceed as follows:
    1. To make changes to the SMP/E data set information, type Y in the Edit SMP/E dataset info? field and press Enter. The screen shown in the following figure is displayed. Parameters specified here apply only to the datasets listed on the screen.
      Specifying details for SMP/E work DSNs

                                  BMC Installer
      Command ===> ________________________________________________ Scroll ===> PAGE
      Enter the following for: BMC AMI DevX File-AID SMP/E DSNs


      If the number of listed datasets exceed the visible screen size, use your
      Up and Down defined PF keys or primary commands to scroll the screen.


      Press Enter to continue or PF3 to return to previous panel.


      Data class:  ________  Storage class:  _________  Mgmt class:
      DASD Unit:   ________  Volser:         _______


      SMPMTS    SYS1.CPWR.MXVJ170                    .SMPMTS
      SMPLTS   SYS1.CPWR.MXVJ170                    .SMPLTS
      SMPSTS    SYS1.CPWR.MXVJ170                    .SMPSTS
      SMPSCDS   SYS1.CPWR.MXVJ170                    .SMPSCDS
    2. Specify storage parameters and DSNs as required.
    3. Press Enter.
    4. To make changes to the distribution zone dataset information, type Y in the Edit DZone dataset info field and press Enter. The screen shown in the following figure is displayed. Parameters specified here apply only to the datasets listed on the screen.
      Specifying details for distribution zone DSNs

                                  BMC Installer
      Command ===> ________________________________________________ Scroll ===> PAGE


      Enter the following for: BMC AMI DevX File-AID Common Components DZone CSI / DSNs
      DZone CSI  SYS1.CPWR.MXVJ170.DZ.CSI
      Data class:  ________  Storage class:  _________  Mgmt class:  ________
      DASD Unit:   ________  Volser:         _______


      If the Zone Library dasasets listed below exceed the visible screen size,                            
      use the Up and Down PF keys or primary commands to scroll the screen.           



      Press Enter to continue or PF3 to return to previous panel.


      Data class:  ________  Storage class:  ________   Mgmt class:  ________
      DASD Unit:   ________  Volser:         ______


      AXVJPATT  SYS1.CPWR.MXVJ170                    .AXVJPATT
      AXVJMOD   SYS1.CPWR.MXVJ170                    .AXVJMOD
      AXVJMENU  SYS1.CPWR.MXVJ170                    .AXVJMENU
      AXVJLOAD  SYS1.CPWR.MXVJ170                    .AXVJLOAD
      AXVJDBRM  SYS1.CPWR.MXVJ170                    .AXVJDBRM
      XVJCLIB   SYS1.CPWR.MXVJ170                    .AXVJCLIB
      AXVJPENU  SYS1.CPWR.MXVJ170                    .AXVJPENU
      AXVJSAMP  SYS1.CPWR.MXVJ170                    .AXVJSAMP
      AXVJTENU  SYS1.CPWR.MXVJ170                    .AXVJTENU
    5. Specify storage parameters and DSNs as required.
    6. Press Enter.
    7. To make changes to the target zone dataset information, type Y in the Edit TZone dataset info field. The screen shown in the following figure is displayed. Parameters specified here apply only to the datasets listed on the screen.
      Specifying details for target zone DSNs

                                  BMC Installer
      Command ===> _________________________________________________ Scroll ===> PAGE


      Enter the following for: BMC AMI DevX File-AID Common Components TZone CSI / DSNs
      TZone CSI  SYS1.CPWR.MXVJ170.DZ.CSI
      Data class:  ________  Storage class:  ________   Mgmt class:  _________
      DASD Unit:   ________  Volser:         ______


      If the Zone Library dasasets listed below exceed the visible screen size, use the
      Up and Down PF keys or primary commands to scroll the screen.


      Press Enter to continue or PF3 to return to previous panel.


      Data class:  ________  Storage class:  ________   Mgmt class:  _______
      DASD Unit:   ________  Volser:         ______


      SXVJPENU   SYS1.CPWR.MXVJ170                   .SXVJPENU
      SXVJMENU   SYS1.CPWR.MXVJ170                   .SXVJMENU
      SXVJLOAD   SYS1.CPWR.MXVJ170                   .SXVJLOAD
      SXVJDBRM   SYS1.CPWR.MXVJ170                   .SXVJDBRM
      SXVJSAMP   SYS1.CPWR.MXVJ170                   .SXVJSAMP
      SXVJPPSB   SYS1.CPWR.MXVJ170                   .SXVJPPSB
      SXVJPATT   SYS1.CPWR.MXVJ170                   .SXVJPATT
      SXVJTENU   SYS1.CPWR.MXVJ170                   .SXVJTENU
      SXVJSMFX   SYS1.CPWR.MXVJ170                   .SXVJSMFX
    8. Specify storage parameters and DSNs as required.
    9. Press Enter.

      Important

      You may need to scroll if the list of datasets is too long to fit on one screen.

  2. If you want to install the Japanese components for the selected product, type Y in the Install Japanese components? field. If not, type N (the default).

    Important

    The examples shown in this procedure are based on installing only English language support. If you are installing Japanese components, the same types of input you provide for the English installation will also be required for those components.

  3. After making any desired edits on the Step 7. Specify target and distribution zone information screen, press Enter to accept the displayed values for the selected product.

Multiple products

After you completed the above steps for the first product, the Step 7. Specify target and distribution zone information screen is redisplayed for the next selected product.

When you complete the above steps for your last selected product, continue with Step-9-Specify-external-files.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*