UPDATED (ID 305690) Flash: Applying IBM APAR OA64141 might cause intermittent errors
A serious problem in the listed products requires immediate attention.
We previously announced this issue. As shown in Resolution, the correcting APAR is now available.
The following table summarizes the change history for this notice:
Date | Description | Section |
---|---|---|
| Correcting APAR is now available | Resolution |
Initial release | Not applicable |
Issue
BMC products might experience intermittent errors when running with IBM APAR OA64141 for z/OS 2.5 and 2.4 applied. IBM has PE'd this APAR.
Examples of the errors that might occur are as follows:
- REORG PLUS completes with RC12 and reports
BMC50294S SYSTEM CATALOG INFORMATION ROUTINE FAILED WITH RC = 246, REASON = 11. DSN = "dsname"
- UNLOAD PLUS completes with RC12 and reports
BMC50294S SYSTEM CATALOG INFORMATION ROUTINE FAILED WITH
RC = 246, REASON = 4
- CHECK PLUS completes with RC246 and reports
BMC50294S SYSTEM CATALOG INFORMATION ROUTINE FAILED WITH RC = 246, REASON = 4. DSN = "dsname"
- BMC AMI Load and Reorg fail with an 0C3 error.
Resolution
The IBM APAR OA65114 with the following PTFs is now available:
z/OS version | PTF |
---|---|
z/OS 2.4 | UJ93520 |
z/OS 2.5 | UJ93521 |
Best practice
We recommend that you set a watch on this page to make sure that you receive email notification of any updates. We will update this notice only in the documentation portal.
To set a watch on this page, follow these steps:
- In the upper right toolbar, click Watch:
- Click Watch this Page.
- Email alerts are sent from docs-noreply@bmc.com, so make sure that @bmc.com is in your mail system's safe list to prevent email alerts from being lost in your spam folder.
If you have questions, please create a Support case at Support Central .