Automation Reporter panel fields
The following table describes the fields on the Automation Reporter panel:
Automation Reporter panel fields
Field name | Description |
---|---|
New DSN | specify the name of the sequential data set that you have preallocated The user-defined data set should be a fixed-block, sequential data set with a maximum record length of 580 bytes. This data set must be preallocated before the Automation Reporter can be activated. |
Disp | specify the disposition of the user-defined sequential data set Valid disposition values are:
|
Interval | specify the collection interval (in minutes) for the Automation Reporter to collect data For example, if you specify 60, the Automation Reporter records the data in the subsystem for the resources and activities every 60 minutes. Specifying any value greater than zero means that the Automation Reporter will collect data. Valid collection intervals range from 10 minutes to 1440 minutes. The default is 10 minutes. |
Off Int | specify the offload interval (in minutes) for the Automation Reporter to offload the data it has collected to the data set For example, if you specify 120, the Automation Reporter writes the data it has collected to the sequential data set every 2 hours. Valid offloading intervals are 60 minutes to 1440 minutes. The default is 1440 (or once a day). |
Alert Queue | specify the name of an ALERT queue to which any ALERTs created by the Automation Reporter is queued For example, if you specify ARALRT, ALERTs are queued to a queue named ARALRT. Any valid ALERT queue name can be entered in this field (default queue name is MAIN). You do not have to enter the name of a pre-existing ALERT queue. You can enter the name of a new queue and it is created for you when the Automation Reporter is activated and ALERTs are generated. |
IRHIST | specifies whether the windows mode Automation Reporter will collect interval data that allows you to perform short term and long term analysis of automation processes and performance This parameter also enables the windows mode Automation Reporter views that show real-time data collected by interval and allows for local or SSI summarization of the automation information. For more information about the windows mode version of the Automation Reporter, refer to the MainView AutoOPERATOR Basic Automation Guide, Volume 2. The default is NO; valid values are YES or NO. |
AR Options | specifies one or more Automation Reporter collectors that will actively collect data Default value is ALL; valid values are ALL (all collectors will be active), ACT, ALT, AUS, CPU, EXE, EXC, EVT, HTH, RES, RST, RUL, TOM, TSL, TSP, ELU, and RLU. Enter a question mark (?) next to this keyword to display a list of the current values. ELU includes EXE data collection and RLU includes RUL data collection. If you do not specify ELU, no EXE data collection is performed unless you specify the EXE value. If you do not specify ELU, no RUL data collection is performed, unless you specify the RUL value. |