Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see DASD MANAGER PLUS for DB2 13.1.

The DASD MANAGER PLUS Main Menu


The Main Menu contains a list of options from which you can make a selection.

To select an option from the menu, type the option number or a question mark (?) for information about this release in the option entry field to the left of the option list.

From the DASD MANAGER PLUS Main Menu, you can select the following:

  • Options for defining and generating service actions
  • Methods for collecting and managing statistics
  • Options for detecting and correcting object exceptions
  • Methods for generating reports
  • Options for defining and managing services
  • Options for defining and managing object sets
  • Methods for managing user options which include setting user and graphic options and viewing the current environment
  • Options for exporting object definitions
  • A list that describes newly supported features for the current version of the product, and other information about the product
Warning

Note

The figure in Panel-navigation displays a map of the primary panels that open when you select an option from the Main Menu.

The Main Menu and otherDASD MANAGER PLUS panels include the following types of fields:

  • Information-only fields are static fields that you cannot edit.
  • Input fields are dynamic fields that you can edit. For example, if these fields contain information, you can write over them. As explained in Setting-up-DASD-MANAGER-PLUS, you can customize highlighting to distinguish input fields from information fields.

    Most DASD MANAGER PLUS panels contain at least one input field. In the Main Menu, the COMMAND line and Current SQLID are examples of input fields. Use the Tab key to move between fields. To exit the DASD MANAGER PLUS Main Menu, press END.

The following figure displays the DASD MANAGER PLUS main options panel.

DASD MANAGER PLUS Main Menu

 DEAE ------------------ DASD MANAGER PLUS vv.rr.mm Main Menu -----------
Command ===>                                                            
                                                                       
Select an option. Then press Enter.                                     
                                                                       
     1. Service Actions    - Define and Generate                        
     2. Statistics         - Collect and Manage                         
     3. Object Exceptions  - Detect and Correct                         
     4. Reports            - Generate                                   
                                                                       
     5. Services           - Define and Manage                          
     6. Object Sets        - Define and Manage                          
     7. User Options       - Manage                                     
     8. Object Definitions - Export                                     
                                                                       
     ?  About This Release                                              
                                                                       
     Current SQLID . . . ERVICEA

 

The following table describes the common fields that appear on the Main Menu and on other DASD MANAGER PLUS panels.

Common information and input fields

Field

Field type

Description

DB2 subsystem ID

Information

Active DB2 subsystem (SSID)

Panel title

Information

Descriptive title for the panel

The title line of the Main Menu includes the product name, version, and maintenance level of DASD MANAGER PLUS that is currently installed.

Warning

Note

If you call DASD MANAGER PLUS Customer Support for assistance, you need the version and maintenance level from the Main Menu panel.

Panel number

Information

Sequence number of the panel (used when a single function spans multiple panels)

Error message

Information

Short text for an error message

An error message overwrites any panel number. Other types of messages, such as warnings, also appear in this space.

COMMAND line

Input

line that you use to enter TSO commands

This field appears on all panels.

Warning

Note

Typically, you run DASD MANAGER PLUS options from the Main Menu. Consequently, you use the option entry field and input fields more frequently than the command line.

Option input field

Input

Field that specifies an option from the list

Because this is, for the most part, a numbered list, you select the option by entering its associated number or a question mark (?) to see what’s new for this release.

Current SQLID

Input

Field that sets the current SQLID

You can use this field if you have authorization. The default value is your TSO logon ID.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*