Rule list parameters for STKSUPP
STKSUPP rule list parameters
Parameter | Purpose | Syntax | Default |
|---|---|---|---|
DEFUNIT | This parameter specifies the default unit name for volumes that are located outside STK silos. Under some circumstances with silos in separate physical locations, the HSC processing can cause a non-silo tape to be allocated to a silo device in a remote location where there might not be a human operator to perform the required function. The DEFUNIT parameter forces non-silo volumes to be allocated to a local silo. | DEFUNIT=xxxxxxxx xxxxxxxx specifies a generic unit name. | DEFUNIT=3480 |
EVENTID | This parameter specifies the identifier that is assigned to a user event in SMEVNTxx. This parameter causes an event to be generated from this function. Note: If EVENTID is used on an FLST SET statement with MODE=INACT, the event will still be issued. The EVENTID parameter will generate events only if the Automation component is licensed and active. | EVENTID=xxxxx xxxxx is the 5-character string that is specified on the EVNTID parameter in SMEVNTxx. | None |
SPLIT | This parameter specifies whether STKSUPP should apply affinity separation to selected resources to allocate separate devices for silo and non-silo volumes. | SPLIT=YES|NO | SPLIT=YES |