Rule list parameters for STKSUPP


The following table lists the parameters that you can specify in a SET statement (in member SMRLSTxx).

STKSUPP rule list parameters

Parameter

Purpose

Syntax

Default

DEFUNIT

This parameter specifies the default unit name for volumes that are located outside STK silos.

Under some circumstances with silos in separate physical locations, the HSC processing can cause a non-silo tape to be allocated to a silo device in a remote location where there might not be a human operator to perform the required function.

The DEFUNIT parameter forces non-silo volumes to be allocated to a local silo.

DEFUNIT=xxxxxxxx

xxxxxxxx specifies a generic unit name.

DEFUNIT=3480

EVENTID

This parameter specifies the identifier that is assigned to a user event in SMEVNTxx.

This parameter causes an event to be generated from this function.

Note: If EVENTID is used on an FLST SET statement with MODE=INACT, the event will still be issued. The EVENTID parameter will generate events only if the Automation component is licensed and active.

EVENTID=xxxxx

xxxxx is the 5-character string that is specified on the EVNTID parameter in SMEVNTxx.

None

SPLIT

This parameter specifies whether STKSUPP should apply affinity separation to selected resources to allocate separate devices for silo and non-silo volumes.

SPLIT=YES|NO
SPLIT=YES



 